Experimental evaluation of water cycle technique for control parameters optimization of double-fed induction generator-based wind turbine

被引:11
|
作者
Bakir, Hale [1 ]
Merabet, Adel [2 ]
Dhar, Rupak Kanti [2 ]
Kulaksiz, Ahmet Afsin [1 ]
机构
[1] Konya Tech Univ, Dept Elect & Elect Engn, Konya, Turkey
[2] St Marys Univ, Div Engn, Halifax, NS B3H 3C3, Canada
关键词
Doubly-fed induction generator; Vector control; Water cycle; Optimization; POWER; ALGORITHM; SYSTEM; DESIGN;
D O I
10.1016/j.jestch.2020.12.024
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a nature-inspired optimization algorithm is employed for parametric tuning of proportional-integral controllers in the vector control of a grid-linked doubly-fed induction generator energy system. The optimization approach is based on the nature-inspired computing technique from the water cycle. The vector control system includes loops for dc-link voltage control at the grid side converter and the rotor current at the rotor side converter. The water cycle optimization is implemented to tune six control parameters by minimizing a cost function carried out using the tracking errors. The cost function value, required in the optimization process, is carried out from a simulated grid-linked doubly fed induction generator energy system. The optimized control parameters are tested on an experimental setup. Experimental results, obtained for a grid-linked doubly-fed induction generator energy system in terms of different optimization methods and conditions, are provided to demonstrate the effectiveness of water cycle optimization technique. As a result of the comparative analysis, it is observed that water cycle technique offers better results in minimizing the overshoot and the response time. (C) 2021 Karabuk University. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:890 / 898
页数:9
相关论文
共 50 条
  • [1] Parameters impact on the performance of a double-fed induction generator-based wind turbine for subsynchronous resonance control
    Zhu, C.
    Hu, M.
    Wu, Z.
    IET RENEWABLE POWER GENERATION, 2012, 6 (02) : 92 - 98
  • [2] Multi-objective proportional-integral-derivative optimization algorithm for parameters optimization of double-fed induction generator-based wind turbines
    Yin, Linfei
    Gao, Qi
    APPLIED SOFT COMPUTING, 2021, 110
  • [3] New techniques to improve the power control in the double-fed induction generator wind turbine
    Ghoudelbourk, S.
    Dib, D.
    Omeiri, A.
    WIND ENGINEERING, 2016, 40 (01) : 86 - 99
  • [4] Quantum deep reinforcement learning for rotor side converter control of double-fed induction generator-based wind turbines
    Yin, Linfei
    Chen, Lichun
    Liu, Dongduan
    Huang, Xiao
    Gao, Fang
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2021, 106
  • [5] Parameters identification based on the voltage drop of double-fed wind generator
    Zhang, Jianhua
    Xin, Fulong
    Chen, Xingying
    Mo, Yueping
    Wang, Jian
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2013, 34 (11): : 1986 - 1992
  • [6] Field oriented current vector control of double-fed induction wind generator
    Schmidt, Istvan
    Veszpremi, Karoly
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 529 - +
  • [7] Double-fed induction generator control for variable speed wind power generation
    Chowdhury, BH
    Chellapilla, S
    ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (9-10) : 786 - 800
  • [9] Proportional–integral–derivative optimization algorithm for double-fed induction generator with the maximum wind power tracking technique
    Linfei Yin
    Qi Gao
    Soft Computing, 2021, 25 : 3097 - 3111
  • [10] Dynamic Response of Wind Turbine with Double-Fed Induction Generator during Grid Voltage Dip
    Zhang, Kao-she
    Su, Ping
    Ning, Lian-hui
    Zhang, Xin-wei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,