Improving mass transfer coefficient prediction in bubbling columns via sphericity measurements

被引:16
|
作者
Botello-Alvarez, JE [1 ]
Navarrete-Bolaños, JL [1 ]
Jiménez-Lslas, H [1 ]
Estrada-Baltazar, A [1 ]
Rico-Martíinez, R [1 ]
机构
[1] Inst Tecnol Celaya, Dept Ingn Quim Bioquim, Celaya 38010, Gto, Mexico
关键词
D O I
10.1021/ie034332z
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The prediction of the oxygen transfer coefficients (k(L)) in bubbling columns is studied. Bubbling columns have important applications as bioreactors. It is found that the coefficient is strongly influenced by the motion and geometric characteristics of the bubbles. In the experiments, it is observed that the maximum transfer coefficient is achieved when a measure of the bubble sphericity reaches a minimum and the slip velocity a maximum. The introduction of characteristic parameters to account for the bubble deformation is proposed. Their use greatly improves the prediction of the oxygen transfer coefficient using standard correlations.