Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model

被引:207
|
作者
Bae, KT [1 ]
Heiken, JP [1 ]
Brink, JA [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
aorta; CT; computed tomography (CT); contrast media; technology; liver;
D O I
10.1148/radiology.206.2.9457200
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the effect of injection rate of contrast medium on aortic and hepatic peak enhancement at computed tomography. MATERIALS AND METHODS: Early pharmacokinetics of contrast enhancement was analyzed theoretically and simulated with a compartment model. Contrast enhancement curves were generated from the model at different injection rates (0.5-10.0 mL/sec). Time-enhancement curves were measured. The effect of contrast medium injection rate on the time and magnitude of peak enhancement was evaluated and validated empirically in pigs. RESULTS: Theoretic predictions and experimental results were in good agreement. Time to aortic peak enhancement was the sum of injection duration and bolus transfer time of contrast medium from the injection site to the aorta. Time to hepatic peak enhancement was the sum of Injection duration and time to equilibrium. The magnitude of peak enhancement increased with the injection rate, but the increase was different in the aorta and liver. CONCLUSION: Use of injection rates above 2 mL/sec did not substantially increase hepatic peak enhancement but helped increase the magnitude of arterial enhancement and temporal separation of arterial and venous phases of enhancement for dual-phase spiral CT.
引用
收藏
页码:455 / 464
页数:10
相关论文
共 40 条
  • [1] Effect of rate of contrast medium injection on hepatic enhancement at CT
    Garcia, PA
    Bonaldi, VM
    Bret, PM
    Liang, LJ
    Reinhold, C
    Atri, M
    RADIOLOGY, 1996, 199 (01) : 185 - 189
  • [2] Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model
    Garcia, P
    Genin, G
    Bret, PM
    Bonaldi, VM
    Reinhold, C
    Atri, M
    ABDOMINAL IMAGING, 1999, 24 (06): : 597 - 603
  • [3] Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model
    P. Garcia
    G. Genin
    P. M. Bret
    V. M. Bonaldi
    C. Reinhold
    M. Atri
    Abdominal Imaging, 1999, 24 : 597 - 603
  • [4] Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model
    Bae, KT
    Heiken, JP
    Brink, JA
    RADIOLOGY, 1998, 207 (03) : 657 - 662
  • [5] Effect of injection rate of contrast medium on pancreatic and hepatic helical CT
    Tublin, ME
    Tessler, FN
    Cheng, SL
    Peters, TL
    McGovern, PC
    RADIOLOGY, 1999, 210 (01) : 97 - 101
  • [6] Effect of decreased contrast injection flow rate on aortic enhancement in 80-KV peak CT with contrast dose reduction
    Morisaka, Hiroyuki
    Matsuura, Koichiro
    Yamaguchi, Haruomi
    Ichikawa, Tomoaki
    Onishi, Hiroshi
    ACTA RADIOLOGICA, 2023, 64 (01) : 353 - 359
  • [7] Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight
    Awai, K
    Hiraishi, K
    Hori, S
    RADIOLOGY, 2004, 230 (01) : 142 - 150
  • [8] Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model
    Bae, KT
    Tran, HQ
    Heiken, JP
    RADIOLOGY, 2000, 216 (03) : 872 - 880
  • [9] Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model
    Bae, KT
    RADIOLOGY, 2003, 227 (03) : 809 - 816
  • [10] Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model
    Bae, KT
    Heiken, JP
    Brink, JA
    RADIOLOGY, 1998, 207 (03) : 647 - 655