Analysis of Induced Voltage at Close Proximity with High Voltage Cables of Electrified Railways

被引:0
|
作者
Lo, W. K. [1 ,2 ]
Wong, Patrick [1 ]
Leung, Sai Wing [1 ,2 ]
Siu, Y. M. [2 ]
Sun, W. N. [2 ]
机构
[1] EMC Consortium Ltd, Hong Kong, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Induced Voltages; cable segaration; touch voltage; fault condition; ITU-T Recommendation; EN61000-5-2;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cables of all types are often arranged to be installed in close proximity, including traction current carrying 3rd rail, LV and HV power cables, and telecommunication and signaling cables, in a railway system. This paper presents an analysis of the induced voltages in the victim cables under both normal and transient/fault conditions amongst cables. Approaches for the analysis of induced voltages for EMC aspects are adapted from ITU-T. Considerations of induced voltages in terms of maximum parallel length among cables for railway systems design in cable management are presented. Shielding effectiveness of metallic trunking as one of the mitigation measures is also discussed in this paper.
引用
收藏
页码:944 / 947
页数:4
相关论文
共 50 条
  • [1] Application of FDTD method in induced voltage calculations in ac electrified railways
    Abdulaziz, I.
    Gupta, N.K.
    [J]. Transactions of the South African Institute of Electrical Engineers, 2005, 96 (01): : 67 - 72
  • [2] Corona loss analysis of high voltage DC transmission lines in close proximity of high voltage AC transmission lines
    Beijing Key Laboratory on High Voltage and EMC , Changping District, Beijing 102206, China
    [J]. Zhongguo Dianji Gongcheng Xuebao, 31 (211-218):
  • [3] Impact of Signal Delay Attack on Voltage Control for Electrified Railways
    Hoang Hai Nguyen
    Tan, Rui
    Yau, David K. Y.
    [J]. TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [4] Induced touch voltage in wayside cables of AC railways caused by traction supply transients
    Jacopo Bongiorno
    [J]. Electrical Engineering, 2023, 105 : 13 - 24
  • [5] Induced touch voltage in wayside cables of AC railways caused by traction supply transients
    Bongiorno, Jacopo
    [J]. ELECTRICAL ENGINEERING, 2023, 105 (01) : 13 - 24
  • [6] ELECTRIC FIELD ANALYSIS OF HIGH VOLTAGE SUBMARINE CABLES
    Vaideki, S.
    Nivetha, M.
    Jayaprakash
    Pugazhendiran, P.
    [J]. 2017 INTERNATIONAL CONFERENCE ON COMPUTATION OF POWER, ENERGY INFORMATION AND COMMUNICATION (ICCPEIC), 2017, : 762 - 766
  • [7] Calculation of the loading capacity of high voltage cables laid in close proximity to heat pipelines using iterative finite-element method
    Nahman, Jovan
    Tanaskovic, Miladin
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 103 : 310 - 316
  • [8] Induced Voltage on Pipeline Located Close to High Voltage Lines Due to Electromagnetic Induction
    AlShahri, Ahmed S.
    Minh Thi Nguyet Dinh
    Nair, Nirmal Kumar C.
    [J]. 2014 Australasian Universities Power Engineering Conference (AUPEC), 2014,
  • [9] Experimental analysis of the evolution of an electrified drop following high voltage switching
    Acero, A. J.
    Ferrera, C.
    Montanero, J. M.
    Herrada, M. A.
    Lopez-Herrera, J. M.
    [J]. EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2013, 38 : 58 - 64
  • [10] Power losses in high voltage cables
    Pasierbek, Artur
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (11): : 215 - 217