Effect of optic disc size or age on evaluation of optic disc variables

被引:38
|
作者
Kee, CW
Koo, HJ
Ji, YH
Kim, SW
机构
[1] Sungkyunkwan Univ, Dept Ophthalmol, Samsung Med Ctr, Coll Med,Kangnam Ku, Seoul 135230, South Korea
[2] Samsung Biomed Res Inst, Dept Biostat, Seoul, South Korea
关键词
D O I
10.1136/bjo.81.12.1046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims/background-It has been reported that the number of optic nerve fibres decrease with age, and the cup/disc (CID) ratio increases as the optic disc size increases. Consequently, the normal value of the optic disc variables measured by an optic disc analyser may change according to the optic disc size or age. The effect of individual variations in optic disc size or age on interpretation of optic disc variables was investigated. Methods-Topographic optic disc variables of 104 normal Asian adults of both sexes aged 40 to 68 were measured using a confocal scanning laser ophthalmoscope (TopSS, Laser Diagnostic Technologies, Inc). Fourteen variables were evaluated according to the optic disc size or age. Statistical analysis was done by regression analysis. Results-With an increase in optic disc size, the increase in cup shape, effective area, 1/2 depth area, CID ratio, neuroretinal rim area, volume above, volume below, and 112 depth volume were statistically significant (p<0.05). However, contour variation, mean contour depth, average depth, maximum depth, average slope, and maximum slope were not affected (p>0.1). Age did not have any significant influence on optic disc variables (p>0.1). Conclusion-Optic disc size, but not age, should be considered in the interpretation of optic disc variables.
引用
收藏
页码:1046 / 1049
页数:4
相关论文
共 50 条
  • [1] The effect of optic disc size or age on evaluation of the optic disc parameters
    Ji, Y
    Koo, H
    Kim, S
    Kee, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3887 - 3887
  • [2] Frequency of optic disc drusen and size of the optic disc
    Jonas, JB
    OPHTHALMOLOGY, 1997, 104 (10) : 1531 - 1532
  • [3] Frequency of optic disc drusen and size of the optic disc - Reply
    Fishman, GA
    Grover, S
    OPHTHALMOLOGY, 1997, 104 (10) : 1532 - 1532
  • [4] Optic Disc Evaluation in Optic Neuropathies The Optic Disc Assessment Project
    O'Neill, Evelyn C.
    Danesh-Meyer, Helen V.
    Kong, George X. Y.
    Hewitt, Alex W.
    Coote, Michael A.
    Mackey, David A.
    Crowston, Jonathan G.
    OPHTHALMOLOGY, 2011, 118 (05) : 964 - 970
  • [5] Optic disc size
    Lempert, P
    OPHTHALMOLOGY, 1996, 103 (03) : 348 - 349
  • [6] The influence of age, gender, refractive error, and optic disc size on the optic disc configuration in Japanese normal eyes
    Kashiwagi, K
    Tamura, M
    Abe, K
    Kogure, S
    Tsukahara, S
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (02): : 200 - 203
  • [7] Optic disc size and glaucoma
    Mehdizadeh, Morteza
    Nowroozzadeh, Mohammad H.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 36 (04): : 395 - 396
  • [8] Optic disc size - Reply
    Ho, AC
    Yannuzzi, LA
    OPHTHALMOLOGY, 1996, 103 (03) : 349 - 349
  • [9] Reproducibility of evaluation of optic disc change for glaucoma with stereo optic disc photographs
    Miglior, S
    Zeyen, T
    Pfeiffer, N
    Cunha-Vaz, J
    Linsen, MC
    Pellicci, L
    Janssens, A
    van der Veken, A
    Nerinckx, F
    Boeyden, V
    Czupper, M
    Wendrix, G
    Detry-Morel, M
    Kestelyn, P
    Van den Abeele, K
    Jacobs, K
    Decock, C
    Goethals, M
    Pourjavan, S
    Maris, K
    Deghislage, C
    Kersten, I
    Vogel, A
    Herkel, U
    Schwenn, O
    Maser-Wahle, M
    Funk, J
    Schmidt, B
    Akbariyeh, N
    Burk, R
    Thomsen, A
    Grehn, F
    Marquardt, D
    Orzalesi, N
    Rossetti, L
    Ferrante, M
    Mandelli, L
    Marini, S
    Bertoni, G
    Blini, M
    De Molfetta, M
    Bonomi, L
    Morbio, R
    Marraffa, M
    Maraini, G
    Gandolfi, S
    Williams, S
    Cimino, L
    Dondi, P
    Lumbroso, B
    OPHTHALMOLOGY, 2003, 110 (02) : 340 - 344
  • [10] Age effect on retina and optic disc normal values
    Neubauer, AS
    Chryssafis, C
    Thiel, M
    Tsinopoulos, I
    Hirneiss, C
    Kampik, A
    OPHTHALMIC RESEARCH, 2005, 37 (05) : 243 - 249