Ocular brachytherapy dosimetry for 103Pd and 125I in the presence of gold nanoparticles: a Monte Carlo study

被引:15
|
作者
Asadi, Somayeh [1 ]
Vaez-zadeh, Mehdi [1 ]
Vahidian, Mohammad [1 ]
Marghchouei, Mahdieh [1 ]
Masoudi, S. Farhad [1 ]
机构
[1] KN Toosi Univ Technol, Dept Phys, POB 15875-4416, Tehran, Iran
来源
关键词
brachytherapy; choroidal melanoma; MCNP5; gold nanoparticles; Pd-103 and I-125; DNA; RADIOSENSITIZATION; RADIOTHERAPY; ENHANCEMENT;
D O I
10.1120/jacmp.v17i3.5945
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle (GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between Pd-103 and I-125 as two ophthalmic brachytherapy sources. Dose distribution in the tumor and healthy tissues has been taken into account for both brachytherapy sources. Also, in certain points of the eye, the ratio of the absorbed dose by the normal tissue in the presence of GNPs to the absorbed dose by the same point in the absence of GNPs has been calculated. In addition, differences of the absorbed dose in the tumor observed in the comparison of simple water phantom and actual simulated human eye in presence of GNPs are also a matter of interest that have been considered in the present work. The difference between the eye globe and the water phantom is more obvious for I-125 than that of the 103Pd when the ophthalmic dosimetry is done in the presence of GNPs. Whenever these nanoparticles are utilized in enhancing the absorbed dose by the tumor, the use of I-125 brachytherapy source will greatly amplify the amount of dose enhancement factor (DEF) in the tumor site without inflicting much damage to healthy organs, when compared to the Pd-103 source. For instance, in the concentration of 30 mg GNPs, the difference amongst the calculated DEF for I-125 between these phantoms is 5.3%, while it is 2.45% for Pd-103. Furthermore, in Monte Carlo studies of eye brachytherapy, more precise definition of the eye phantom instead of a water phantom will become increasingly important when we use I-125 as opposed to Pd-103.
引用
收藏
页码:90 / 99
页数:10
相关论文
共 50 条
  • [1] Ocular Brachytherapy Dosimetry for 103Pd and 125I in The Presence of Gold Nanoparticles: Monte Carlo Study
    Asadi, S.
    Vaez-zadeh, M.
    Vahidian, M.
    Marghchouei, M.
    Masoudi, S. Farhad
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S105 - S105
  • [2] Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy
    Thomson, R. M.
    Taylor, R. E. P.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5530 - 5543
  • [3] Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy with various seed models
    Thomson, R. M.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2010, 37 (01) : 368 - 376
  • [4] GEANT4 versus MCNP5: Monte-Carlo ophthalmic brachytherapy dosimetry in the presence of gold nanoparticles for 125I and 103Pd
    Qazvini, Sh. Vahidian
    Vahidian, M.
    Asadi, S.
    Vaez-zadeh, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S105 - S105
  • [5] Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom
    Lesperance, Marielle
    Martinov, M.
    Thomson, R. M.
    [J]. MEDICAL PHYSICS, 2014, 41 (03)
  • [6] Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code
    Bohm, TD
    DeLuca, PM
    DeWerd, LA
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 701 - 711
  • [7] Evaluated phantom material for 125I and 103Pd dosimetry
    Wallace, R
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1201 - 1201
  • [8] COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs
    Melhus, Christopher S.
    Rivard, Mark J.
    [J]. MEDICAL PHYSICS, 2008, 35 (07) : 3364 - 3371
  • [9] Monte Carlo and experimental dosimetry of an 125I brachytherapy seed
    Dolan, James
    Li, Zuofeng
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2006, 33 (12) : 4675 - 4684
  • [10] A Monte Carlo study on the radio-sensitization effect of gold nanoparticles in brachytherapy of prostate by 103Pd seeds
    Jangjoo, Amir Ghasemi
    Ghiasi, Hosein
    Mesbahi, Asghar
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (02): : 87 - 92