Clinical impact of 11C-methionine PET on expected management of patients with brain neoplasm

被引:53
|
作者
Yamane, Tomohiko [1 ]
Sakamoto, Setsu [2 ]
Senda, Michio [1 ]
机构
[1] Inst Biomed Res & Innovat, Div Mol Imaging, Chuo Ku, Kobe, Hyogo 6500047, Japan
[2] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo 657, Japan
关键词
C-11-Methionine; Positron emission tomography (PET); Brain neoplasm; Clinical impact; POSITRON-EMISSION-TOMOGRAPHY; IMPROVES PROGNOSTIC STRATIFICATION; LOW-GRADE GLIOMAS; MAGNETIC-RESONANCE-SPECTROSCOPY; RADIATION NECROSIS; DIFFERENTIAL-DIAGNOSIS; STEREOTACTIC RADIOSURGERY; FDG-PET; METHIONINE; MULTICENTER;
D O I
10.1007/s00259-009-1302-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We retrospectively examined the clinical efficacy of C-11-methionine positron emission tomography (C-11-MET PET) in patients with brain neoplasm, especially whether the C-11-MET PET changed the clinical management and whether the change was beneficial or detrimental. This study reviewed 89 C-11-MET PET scans for 80 patients (20 scans for initial diagnosis of brain tumor and 69 scans for differentiating tumor recurrence from radiation necrosis). Final diagnosis and the effect on the intended management were obtained from the questionnaire to the referring physicians or directly from the medical records. The diagnostic sensitivity, specificity, and accuracy for the C-11-MET PET were evaluated. Regarding the management impact, the rate of scans that caused changes in intended management was also evaluated. Moreover, the occurrence of scans having detrimental diagnostic impact (DDI) and beneficial diagnostic impact (BDI) were evaluated. Sensitivity, specificity, and accuracy of C-11-MET PET was 87.8, 80.0, and 85.9%. The intended management was changed in 50.0% of the scans. DDI and BDI were observed in 4.3 and 36.2% of the total relevant scans, respectively. C-11-MET PET can provide useful information in initial diagnosis and differentiating tumor recurrence from radiation necrosis. The intended management was changed in half of the scans. Since a few cases did not receive the requisite treatment due to false-negative results of C-11-MET PET, management decision should be made carefully, especially in the case of a negative scan.
引用
收藏
页码:685 / 690
页数:6
相关论文
共 50 条
  • [1] Clinical impact of 11C-methionine PET on expected management of patients with brain neoplasm
    Tomohiko Yamane
    Setsu Sakamoto
    Michio Senda
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 685 - 690
  • [2] Erratum to: Clinical impact of 11C-methionine PET on expected management of patients with brain neoplasm
    Tomohiko Yamane
    Setsu Sakamoto
    Michio Senda
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 (4) : 831 - 831
  • [3] Clinical impact of C-11 methionine PET on expected management of patients with brain neoplasm
    Yamane, T.
    Sakamoto, S.
    Senda, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S325 - S326
  • [4] Clinical impact of 11C-Methionine PET/CT findings in the management of patients with brain lesions
    Gutierrez-Gonzalez, A.
    Martinez-Rodriguez, I.
    Andres-Pacheco, J.
    De Arcocha-Torres, M.
    Sanchez-Salmon, A.
    Jimenez-Bonilla, J.
    Mendi-Barcina, V.
    Martinez-Amador, N.
    F. Gomez-De la Fuente
    Bota-Bota, A.
    Pombo-Lopez, M.
    Garcia-Ruiz, A.
    Rodil-Gallego, M.
    Quirce, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S453 - S453
  • [5] Contribution of 11C-Methionine PET/CT in the management of patients with brain tumors
    Lopez-Defillo, J. L.
    Martinez-Rodriguez, I.
    De Arcocha-Torres, M.
    Jimenez-Bonilla, J.
    Quirce, R.
    Jimenez-Alonso, M.
    Gomez-De La Fuente, F.
    Lavado-Perez, C.
    Martinez-Amador, N.
    Banzo, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S261 - S261
  • [6] Accumulation of 11C-methionine in the normal pituitary gland on 11C-methionine PET
    Tomura, Noriaki
    Saginoya, Toshiyuiki
    Mizuno, Yasuaki
    Goto, Hiromi
    ACTA RADIOLOGICA, 2017, 58 (03) : 362 - 366
  • [7] Timing of a static 11C-methionine brain PET imaging
    Hascsi, Z.
    Szucs, B.
    Balkay, L.
    Garai, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S392 - S392
  • [8] 11C-methionine PET as prognostic indicator of survival in patients with primary brain tumors
    Luyx, D.
    Raftopoulos, C.
    Renard, L.
    Godfraind, C.
    Grandin, C.
    Lonneux, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S248 - S249
  • [9] Preoperative PET with 11C-methionine in patients with hyperparathyroidism.
    Otto, D
    Behrend, M
    Börner, AR
    Oetting, G
    Weckesser, E
    Hofmann, M
    Knapp, WH
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 160P - 160P
  • [10] 11C-methionine PET/CT findings in benign brain disease
    Nakajima, Reiko
    Kimura, Ken
    Abe, Koichiro
    Sakai, Shuji
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (06) : 279 - 288