Myocardial iron overload by cardiovascular magnetic resonance native segmental T1 mapping: a sensitive approach that correlates with cardiac complications

被引:32
|
作者
Meloni, Antonella [1 ]
Martini, Nicola [1 ]
Positano, Vincenzo [1 ]
De Luca, Antonio [2 ]
Pistoia, Laura [1 ]
Sbragi, Sara [3 ]
Spasiano, Anna [4 ]
Casini, Tommaso [5 ]
Bitti, Pier Paolo [6 ]
Allo, Massimo [7 ]
Grazia Sanna, Paola Maria [8 ]
De Caterina, Raffaele [3 ]
Sinagra, Gianfranco [2 ]
Pepe, Alessia [1 ]
机构
[1] Fdn G Monasterio CNR Reg Toscana, Magnet Resonance Imaging Unit, Pisa, Italy
[2] Univ Trieste, Cardiovasc Dept, Trieste, Italy
[3] Univ Pisa, Cardiovasc Div, Pisa, Italy
[4] Azienda Osped Rilievo Nazl A Cardarelli, Unita Operat Semplice Dipartimentale Malattie Rar, Naples, Italy
[5] Osped Meyer, Ctr Talassemie Emoglobinopatie, Florence, Italy
[6] Presidio Osped San Francesco ASL Nuoro, Serv Immunoemal & Med Trasfus, Dipartimento Servizi, Nuoro, Italy
[7] Osped San Giovanni Dio, Asp Crotone, Ematol Microcitemia, Crotone, Italy
[8] Azienda Osped Univ Sassari, Serv Trasfus Aziendale, Sassari, Italy
关键词
Iron overload; Thalassaemia major; Magnetic resonance imaging; Cardiovascular diseases; THALASSEMIA MAJOR; EXTRACELLULAR VOLUME; T2-ASTERISK-MAGNETIC RESONANCE; CONSENSUS STATEMENT; IN-VIVO; HEART; DISEASE; T2; PATTERNS; CMR;
D O I
10.1186/s12968-021-00765-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundWe compared cardiovascular magnetic resonance segmental native T1 against T2* values for the detection of myocardial iron overload (MIO) in thalassaemia major and we evaluated the clinical correlates of native T1 measurements. MethodsWe considered 146 patients (87 females, 38.711.1 years) consecutively enrolled in the Extension-Myocardial Iron Overload in Thalassaemia Network.T1 and T2* values were obtained in the 16 left ventricular (LV) segments. LV function parameters were quantified by cine images. Post-contrast late gadolinium enhancement (LGE) and T1 images were acquired. Results64.1% of segments had normal T2* and T1 values while 10.1% had pathologic T2* and T1 values. In 526 (23.0%) segments, there was a pathologic T1 and a normal T2* value while 65 (2.8%) segments had a pathologic T2* value but a normal T1 and an extracellular volume (ECV)>= 25% was detected in 16 of 19 segments where ECV was quantified.Global native T1 was independent from gender or LV function but decreased with increasing age. Patients with replacement myocardial fibrosis had significantly lower native global T1. Patients with cardiac complications had significantly lower native global T1.Conclusions The combined use of both segmental native T1 and T2* values could improve the sensitivity for detecting MIO. Native T1 is associated with cardiac complications in thalassaemia major.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Myocardial iron overload by cardiovascular magnetic resonance native segmental T1 mapping: a sensitive approach that correlates with cardiac complications
    Antonella Meloni
    Nicola Martini
    Vincenzo Positano
    Antonio De Luca
    Laura Pistoia
    Sara Sbragi
    Anna Spasiano
    Tommaso Casini
    Pier Paolo Bitti
    Massimo Allò
    Paola Maria Grazia Sanna
    Raffaele De Caterina
    Gianfranco Sinagra
    Alessia Pepe
    Journal of Cardiovascular Magnetic Resonance, 23
  • [2] Detection of myocardial iron overload with magnetic resonance by native T1 and T2*mapping using a segmental approach
    Pepe, A.
    Martini, N.
    De Marchi, D.
    Barison, A.
    Pistoia, L.
    Bisconte, M. G.
    Pulini, S.
    Massa, A.
    Carollo, A.
    Serra, M.
    Positano, V
    Meloni, A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 10 - 11
  • [3] Detection of Myocardial Iron Overload with Magnetic Resonance By Native T1 and T2*Mapping Using a Segmental Approach
    Pepe, Alessia
    Pistoia, Laura
    Martini, Nicola
    De Marchi, Daniele
    Barison, Andrea
    Maggio, Aurelio
    Giovangrossi, Piera
    Bulgarelli, Simona
    Pasin, F. Mehtap
    Sarli, Roberto
    Massa, Antonella
    Roccamo, Gaetano
    Caini, Mauro
    Positano, Vincenzo
    Meloni, Antonella
    BLOOD, 2018, 132
  • [4] Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload
    Sado, Daniel M.
    Maestrini, Viviana
    Piechnik, Stefan K.
    Banypersad, Sanjay M.
    White, Steven K.
    Flett, Andrew S.
    Robson, Matthew D.
    Neubauer, Stefan
    Ariti, Cono
    Arai, Andrew
    Kellman, Peter
    Yamamura, Jin
    Schoennagel, Bjoern P.
    Shah, Farrukh
    Davis, Bernard
    Trompeter, Sara
    Walker, Malcolm
    Porter, John
    Moon, James C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (06) : 1505 - 1511
  • [5] Detection of cardiac iron overload with native magnetic resonance T1 and T2 mapping in patients with thalassemia
    Krittayaphong, Rungroj
    Zhang, Shuo
    Saiviroonporn, Pairash
    Viprakasit, Vip
    Tanapibunpon, Prajak
    Komoltri, Chulaluk
    Wangworatrakul, Wipaporn
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 248 : 421 - 426
  • [6] Novel cardiac magnetic resonance biomarkers: native T1 and extracellular volume myocardial mapping
    Cannao, Paola Maria
    Altabella, Luisa
    Petrini, Marcello
    Ali, Marco
    Secchi, Francesco
    Sardanelli, Francesco
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2016, 18 (0E) : E64 - E71
  • [7] Global, segmental and layer specific analysis of myocardial involvement in Duchenne muscular dystrophy by cardiovascular magnetic resonance native T1 mapping
    Ke Xu
    Hua-yan Xu
    Rong Xu
    Lin-jun Xie
    Zhi-gang Yang
    Li Yu
    Bin Zhou
    Hang Fu
    Hui Liu
    Xiao-tang Cai
    Ying-kun Guo
    Journal of Cardiovascular Magnetic Resonance, 23
  • [8] Global, segmental and layer specific analysis of myocardial involvement in Duchenne muscular dystrophy by cardiovascular magnetic resonance native T1 mapping
    Xu, Ke
    Xu, Hua-yan
    Xu, Rong
    Xie, Lin-jun
    Yang, Zhi-gang
    Yu, Li
    Zhou, Bin
    Fu, Hang
    Liu, Hui
    Cai, Xiao-tang
    Guo, Ying-kun
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [9] Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
    Teixeira, Tiago
    Hafyane, Tarik
    Stikov, Nikola
    Akdeniz, Cansu
    Greiser, Andreas
    Friedrich, Matthias G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18 : 1 - 12
  • [10] Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
    Tiago Teixeira
    Tarik Hafyane
    Nikola Stikov
    Cansu Akdeniz
    Andreas Greiser
    Matthias G. Friedrich
    Journal of Cardiovascular Magnetic Resonance, 18