Device profile of the Nerivio™ for acute migraine treatment: overview of its efficacy and safety

被引:16
|
作者
Rapoport, Alan M. [1 ]
Lin, Tamar [2 ]
机构
[1] UCLA, David Geffen Sch Med, Los Angeles, CA 90095 USA
[2] Theran Bioelect Ltd, Netanya, Israel
关键词
Acute treatment; conditioned pain modulation; headache; migraine; migraine treatment; Nerivio; remote electrical neuromodulation; EPISODIC MIGRAINE; TRIPTANS; STIMULATION; PREVENTION; HEADACHE; AGONISTS; OVERUSE; DRUGS;
D O I
10.1080/17434440.2019.1695599
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Noninvasive neuromodulation devices represent an emerging field in the acute treatment of migraine. High efficacy, favorable safety profile, good tolerability and low cost are important factors for the desired shift to non-pharmacological treatments. This will have the potential to improve the quality of life of people with migraine and reduce the risk for adverse events and medication overuse headache (MOH). Areas covered: Nerivio (TM) (Theranica Bio-Electronics, Israel) is a novel FDA-cleared remote electrical neuromodulation (REN) device for acute treatment of migraine. This review highlights the mechanism of action of REN and summarizes the clinical data. Nerivio (TM) has been studied in two randomized trials which provide support for the efficacy and safety of the device. Post-hoc analyses suggest that the efficacy of REN is non-inferior to usual care in general and to acute pharmacological treatments specifically. Expert commentary: Nerivo (TM) integrates clinically meaningful efficacy with a high safety profile, satisfying a great unmet need in migraine acute care. The unique mechanism of action, in which the electrical stimulation is applied to peripheral nerves in the upper arm, permits the introduction of an innovative device with high efficacy and superior and improved usability aspects compared with acute pharmacological treatments and other approved devices.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 50 条
  • [1] Device profile of Nerivio for the acute and preventive treatment of episodic or chronic migraine in patients 12 years and older
    Babaei, Mahsa
    Rapoport, Alan M.
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (06) : 433 - 447
  • [2] Device profile of the Wingspan Stent System for the treatment of intracranial atherosclerotic disease: overview of its safety and efficacy
    Barnard, Zachary R.
    Alexander, Michael J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (03) : 167 - 171
  • [3] Device profile of the Proclaim XR neurostimulation system for the treatment of chronic pain: an overview of its safety and efficacy
    Hagedorn, Jonathan M.
    Engle, Alyson M.
    Ghosh, Priyanka
    Deer, Timothy R.
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (06) : 499 - 505
  • [4] Nerivio® remote electrical neuromodulation for acute treatment of chronic migraine
    Nierenburg, Hida
    Stark-Inbar, Alit
    PAIN MANAGEMENT, 2021,
  • [5] Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy
    Bates, Mark C.
    Stone, Gregg W.
    Chen, Chao-Yin
    Spiering, Wilko
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (07) : 649 - 657
  • [6] Device profile of the FLEX Vessel Prep System for the treatment of peripheral arterial disease: overview of its safety and efficacy
    Zeller, Thomas
    Boehme, Tanja
    Beschorner, Ulrich
    Noory, Elias
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (01) : 25 - 29
  • [7] Device profile of the Zephyr endobronchial valve in heterogenous emphysema: overview of its safety and efficacy
    Verga, Steven R.
    Criner, Gerard J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (09) : 823 - 832
  • [8] Nerivio(R) remote electrical neuromodulation for acute treatment of chronic migraine
    Nierenburg, Hida
    Stark-Inbar, Alit
    PAIN MANAGEMENT, 2021, 12 (03) : 267 - 281
  • [9] Safety and efficacy of eletriptan in the treatment of acute migraine
    Takiya, L
    Piccininni, LC
    Kamath, V
    PHARMACOTHERAPY, 2006, 26 (01): : 115 - 128
  • [10] Device profile of the AltaValve system for transcatheter mitral valve replacement: overview of its safety and efficacy
    Alperi, Alberto
    del Val, David
    Ferreira-Neto, Alfredo Nunes
    Bernier, Mathieu
    Freitas-Ferraz, Afonso B.
    Dagenais, Francois
    Rodes-Cabau, Josep
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (07) : 627 - 636