Peeling the Otolith of Fish: Optimal Parameterization for Micro-CT Scanning

被引:9
|
作者
Vasconcelos-Filho, Jonas E. [1 ,2 ]
Thomsen, Felix S. L. [3 ]
Stosic, Borko [1 ,4 ]
Antonino, Antonio C. D. [5 ]
Duarte, Daniel A. [5 ]
Heck, Richard J. [6 ]
Lessa, Rosangela P. T. [7 ]
Santana, Francisco M. [8 ]
Ferreira, Beatrice P. [2 ]
Duarte-Neto, Paulo J. [1 ,4 ]
机构
[1] Univ Fed Rural Pernambuco, Grad Program Biometry & Appl Stat, Recife, PE, Brazil
[2] Univ Fed Rural Pernambuco, Dept Oceanog, Recife, PE, Brazil
[3] Natl Univ South, Dept Elect & Comp Engn, Buenos Aires, DF, Argentina
[4] Univ Fed Rural Pernambuco, Dept Stat & Informat, Recife, PE, Brazil
[5] Univ Fed Pernambuco, Dept Nucl Energy, Recife, PE, Brazil
[6] Univ Guelph, Sch Environm Sci, Guelph, ON, Canada
[7] Univ Fed Rural Pernambuco, Dept Fisheries & Aquaculture, Recife, PE, Brazil
[8] Univ Fed Rural Pernambuco, Acad Unit Serra Talhada, Recife, PE, Brazil
关键词
eco-densitometry; fishery biology; Hounsfield units; Meshlab; radiodensity; 3D otoliths; GROWTH; AGE; MICROSTRUCTURE; TOMOGRAPHY; VALIDATION; BRAZIL;
D O I
10.3389/fmars.2019.00728
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, we aim to provide optimal parameters for micro-computed tomography scans of fish otoliths. We tested fifteen different combinations to sagittae. The images were scaled to Hounsfield units, and segmented in two distinct volumes-of-interest (external and internal). The strategy we applied, for identifying optimum scan settings for otoliths, included analyses of the sinogram, the distribution of the Hounsfield units and the signal-to-noise ratio. Based on these tests, the optimum sets of parameters for the acquisition of tomographic images of sagittal otoilths were 80 kV, 220 mu A, and 0.5 mm aluminum filter. The method allowed 3D shape analysis, internal and external density distribution, layer-by-layer density segmentation, and a potential objective method to count growth rings in otoliths. It was possible to compare mean densities between species, and we observed a significant difference among them. In addition, there are ontogenic changes, which could be increasing or decreasing the density. In this study, we applied tomography for several otolith analysis, that could be of great interest for future studies in diverse areas that use otoliths as the basic structure of analysis, or represents a new research line called eco-densitometry of otoliths, where tomography could be applied to explore the density within an ecological perspective.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] An osteological assessment of cyclopia by micro-CT scanning
    Kramer, Beverley
    Molema, Kgalaletso
    Hutchinson, Erin F.
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (09) : 1053 - 1063
  • [2] An osteological assessment of cyclopia by micro-CT scanning
    Beverley Kramer
    Kgalaletso Molema
    Erin F. Hutchinson
    Surgical and Radiologic Anatomy, 2019, 41 : 1053 - 1063
  • [3] Finding fossils in Malapa breccia - medical CT scanning or micro-CT scanning?
    Smilg, Jacqueline S.
    SOUTH AFRICAN JOURNAL OF SCIENCE, 2017, 113 (11-12) : 87 - 92
  • [4] redescribed and illustrated from micro-CT scanning the type female
    NG, Peter K. L.
    Clark, Paul F.
    Clark, Brett
    Kamanli, Seyit A.
    ZOOTAXA, 2021, 4969 (02) : 377 - 391
  • [5] Micro-CT Scanning Analysis for Inner Structure of Porous Media
    Zhang Yang
    Peng Xiaofeng
    HEAT TRANSFER-ASIAN RESEARCH, 2007, 36 (04): : 208 - 214
  • [6] In vivo micro-CT scanning of a rabbit distal femur:: Repeatability and reproducibility
    Voor, Michael J.
    Yang, Shuo
    Burden, Robert L.
    Waddell, Seld W.
    JOURNAL OF BIOMECHANICS, 2008, 41 (01) : 186 - 193
  • [7] Exploring miniature insect brains using micro-CT scanning techniques
    Smith, Dylan B.
    Bernhardt, Galina
    Raine, Nigel E.
    Abel, Richard L.
    Sykes, Dan
    Ahmed, Farah
    Pedroso, Inti
    Gill, Richard J.
    SCIENTIFIC REPORTS, 2016, 6
  • [8] Performance Evaluation of the GE eXplore CT 120 Micro-CT for Various Scanning Protocols
    Bahri, Mohamed A.
    Bretin, Florian
    Warnock, Geoffrey I.
    Luxen, Andre
    Salmon, Eric
    Plenevaux, Alain
    Seret, Alain
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3783 - 3785
  • [9] Accuracy of cancellous bone volume fraction measured by micro-CT scanning
    Ding, M
    Odgaard, A
    Hvid, I
    JOURNAL OF BIOMECHANICS, 1999, 32 (03) : 323 - 326
  • [10] Characterising neovascularisation in fracture healing with laser Doppler and micro-CT scanning
    W. Macdonald
    S. J. Shefelbine
    Medical & Biological Engineering & Computing, 2013, 51 : 1157 - 1165