Biomechanical comparison of hallux valgus correction using the proximal chevron osteotomy fixed with a medial locking plate and the Ludloff osteotomy fixed with two screws

被引:18
|
作者
Scott, Aaron T. [1 ]
DeOrio, James K. [2 ]
Montijo, Harvey E. [3 ]
Glisson, Richard R. [2 ]
机构
[1] Wake Forest Univ, Sch Med, Dept Orthopaed Surg, Winston Salem, NC 27103 USA
[2] Duke Univ, Med Ctr, Div Orthopaed Surg, Durham, NC 27710 USA
[3] Carolinas Med Ctr, Dept Orthopaed Surg, Charlotte, NC 28203 USA
关键词
Hallux valgus; Bunionectomy; Chevron; Ludloff; Locking plate; Screw; CRESCENTIC OSTEOTOMY; FIXATION; SURGERY;
D O I
10.1016/j.clinbiomech.2009.12.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: For moderate-to-severe hallux valgus deformities with a 1-2 intermetatarsal angle in excess of 15 degrees, a proximal first metatarsal osteotomy is indicated. The ideal osteotomy has yet to be defined, but should inherently limit the incidence of dorsal malunion and allow for early ambulation. The present study evaluates the mechanical integrity of two popular first metatarsal osteotomies. Methods: Ten matched pairs of fresh-frozen cadaveric first metatarsals were harvested. In one metatarsal from each pair, a Ludloff osteotomy was created and fixed with two cannulated 3.5 mm screws. In the contralateral first metatarsal, a proximal chevron osteotomy was performed and subsequently fixed with a medially applied locking plate. All specimens were mounted within an Instron 1321 servohydraulic materials testing machine and subjected to a plantar-to-dorsal cantilever bending protocol for 1000 cycles. Findings: Two of ten Ludloff osteotomies failed prior to completion of 1000 loading cycles by fracture at the distal screw site, whereas six of ten proximal chevrons failed prior to the 1000th cycle. The mode of failure in this group was by cut-out of the plantar-proximal screw. The bending stiffness of the Ludloff osteotomy exceeded that of the proximal chevron at all measurement points between the 1st and 200th load cycles (P < 0.05). After 200 cycles, an inadequate number of plate constructs survived to allow statistical comparison. Interpretation: The results of the present study indicate that the proximal chevron osteotomy fixed with a medially based locking plate exhibits mechanical properties inferior to those of the Ludloff osteotomy under the tested conditions. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 50 条
  • [1] Biomechanical evaluation of the proximal chevron osteotomy in comparison to the Lapidus arthrodesis for the correction of hallux valgus deformities
    Maximilian F. Kasparek
    Emir Benca
    Lena Hirtler
    Madeleine Willegger
    Friedrich Boettner
    Shahin Zandieh
    Johannes Holinka
    Reinhard Windhager
    Reinhard Schuh
    [J]. International Orthopaedics, 2022, 46 : 2257 - 2264
  • [2] Biomechanical evaluation of the proximal chevron osteotomy in comparison to the Lapidus arthrodesis for the correction of hallux valgus deformities
    Kasparek, Maximilian F.
    Benca, Emir
    Hirtler, Lena
    Willegger, Madeleine
    Boettner, Friedrich
    Zandieh, Shahin
    Holinka, Johannes
    Windhager, Reinhard
    Schuh, Reinhard
    [J]. INTERNATIONAL ORTHOPAEDICS, 2022, 46 (10) : 2257 - 2264
  • [3] Comparison of the Proximal Chevron and Ludloff Osteotomies for the Correction of Hallux Valgus
    Choi, Woo Jin
    Yoon, Han Kook
    Yoon, Hang Seob
    Kim, Bom Soo
    Lee, Jin Woo
    [J]. FOOT & ANKLE INTERNATIONAL, 2009, 30 (12) : 1154 - 1160
  • [4] Modified chevron osteotomy fixed with stofella pin for hallux valgus
    Kuerklue, Mustafa
    Demiralp, Bahtiyar
    Yurttas, Yueksel
    Cicek, Engin Ilker
    Atesalp, Ali Sabri
    [J]. FOOT & ANKLE INTERNATIONAL, 2008, 29 (05) : 478 - 482
  • [5] Proximal metatarsal osteotomy in hallux valgus correction: A comparison of crescentic and chevron procedures
    Markbreiter, LA
    Thompson, FM
    [J]. FOOT & ANKLE INTERNATIONAL, 1997, 18 (02) : 71 - 76
  • [6] A comparison of proximal and distal chevron osteotomy for the correction of moderate hallux valgus deformity
    Park, C-H
    Jang, J-H
    Lee, S-H
    Lee, W-C
    [J]. BONE & JOINT JOURNAL, 2013, 95B (05): : 649 - 656
  • [7] Proximal oblique metatarsal osteotomy for hallux valgus using a plantar locking plate
    Ohzawa, Seiya
    Kubota, Makoto
    [J]. FOOT AND ANKLE SURGERY, 2018, 24 (06) : 501 - 505
  • [8] Mini Locking Plate as "Medial Buttress" for Oblique Osteotomy for Hallux Valgus
    Stamatis, Emmanouil D.
    Chatzikomninos, Ioannis E.
    Karaoglanis, Georgios C.
    [J]. FOOT & ANKLE INTERNATIONAL, 2010, 31 (10) : 920 - 922
  • [9] Correction of hallux valgus using lateral soft-tissue release and proximal chevron osteotomy through a medial incision
    Lee, Woo-Chun
    Kim, Yu-Mi
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A : 82 - 89
  • [10] Proximal opening wedge metatarsal osteotomy for correction of moderate to severe hallux valgus deformity using a locking plate
    Badekas, Athanasios
    Georgiannos, Dimitrios
    Lampridis, Vasilios
    Bisbinas, Ilias
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (09) : 1765 - 1770