Utility of Caudal Angulation for Venous Access under Fluoroscopic Guidance during Cardiovascular Implantable Electronic Device Implantation

被引:1
|
作者
Deepti, Siddharthan [1 ]
Singh, Dhara [1 ]
Ghati, Nirmal [1 ]
Shaw, Manish [2 ,3 ]
Naik, Nitish [1 ]
Singh, Sandeep [1 ]
机构
[1] All India Inst Med Sci, Dept Cardiol, New Delhi, India
[2] All India Inst Med Sci, Dept Cardiovasc Radiol, New Delhi, India
[3] All India Inst Med Sci, Dept Endovasc Intervent, New Delhi, India
关键词
Caudal fluoroscopy; Venous access; CIED;
D O I
10.1159/000515360
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Axillary venous access is preferred for CIED implantation. The procedure is usually performed under fluoroscopic guidance in anteroposterior (A-P) view. However, there is a lack of perception of depth in this view with a fear of creating complications. Caudal fluoroscopy (adding 30 degrees-35 degrees caudal angulation to A-P projection) has been proposed to circumvent this problem. Objective: The aim of this study was to elucidate the advantages of caudal fluoroscopy using fluoroscopic images, contrast venograms, and CT angiography images of axillary vein. Methods: The fluoroscopic images and contrast venograms obtained in the A-P view were compared with caudal fluoroscopy in patients undergoing CIED implantation at our centre. Also, the CT angiography images of axillary vein were reconstructed to understand the relative anatomy of the vein and the underlying lung parenchyma, simulating these 2 projections. Results: The CT angiography images, contrast venograms, and fluoroscopic images confirmed that caudal fluoroscopy allows better visualization of the vein in relation to the lung parenchyma and rib cage. Analysis of fluoroscopic images revealed that the bend of the first rib formed a conical prominence in caudal fluoroscopy. This served as an important bony landmark for successful venous access, which was usually obtained while the needle was being directed towards this prominence in caudal fluoroscopy. Conclusions: The proposed advantages of caudal fluoroscopy for CIED implantation have been elucidated by analysis of CT angiography images, contrast venograms, and fluoroscopic images.
引用
收藏
页码:464 / 468
页数:5
相关论文
共 50 条
  • [1] IMPLANTATION OF PAS PORT VENOUS ACCESS DEVICE IN THE FOREARM UNDER FLUOROSCOPIC GUIDANCE
    BRANTZAWADZKI, M
    ANTHONY, M
    MERCER, EC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1127 - 1128
  • [2] Prospective randomized study of axillary venous access with or without fluoroscopy-guided in cardiovascular implantable electronic device implantation
    Cheng, Xianlu
    Jiang, Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (05): : 6128 - 6133
  • [3] Elimination of pneumothorax and hemothorax during placement of implantable venous access ports using ultrasound and fluoroscopic guidance
    Fankhauser, Grant T.
    Fowl, Richard J.
    Stone, William M.
    Money, Samuel R.
    VASCULAR, 2013, 21 (06) : 345 - 348
  • [4] Pacemaker implantation through pericardial reflections under fluoroscopic guidance: a novel approach for patients with limited venous access
    R Costa
    M Scanavacca
    KR Silva
    M Martinelli Filho
    MS Lacerda
    RM Oliveira
    ES Crevelari
    FB Jatene
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [5] Institutional Variation in Quality of Cardiovascular Implantable Electronic Device Implantation RESPONSE
    Ranasinghe, Isuru
    Hossain, Sadia
    Ganesan, Anand
    Krumholz, Harlan M.
    McGavigan, Andrew
    ANNALS OF INTERNAL MEDICINE, 2020, 172 (02) : 166 - 167
  • [6] Cardiovascular Implantable Electronic Device Surgery Following Left Ventricular Assist Device Implantation
    Black-Maier, Eric
    Lewis, Robert K.
    Loungani, Rahul
    Rehorn, Michael
    Friedman, Daniel J.
    Bishawi, Muath
    Schroder, Jacob N.
    Milano, Carmelo A.
    Katz, Jason N.
    Patel, Chetan B.
    Rogers, Joseph G.
    Hegland, Donald D.
    Jackson, Kevin P.
    Frazier-Mills, Camille
    Pokorney, Sean D.
    Daubert, James P.
    Piccini, Jonathan P.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (09) : 1131 - 1139
  • [7] Peripheral insertion of a central venous access device under fluoroscopic guidance using a Peripherally Accessed System (PAS) port in the forearm
    Yasuhiro Hata
    Sojiro Morita
    Yoshitaka Morita
    Toshihide Awatani
    Motohiro Takasaki
    Tadashi Horimi
    Zen Ozawa
    CardioVascular and Interventional Radiology, 1998, 21 : 230 - 233
  • [8] Peripheral insertion of a central venous access device under fluoroscopic guidance using a peripherally accessed system (PAS) port in the forearm
    Hata, Y
    Morita, S
    Morita, Y
    Awatani, T
    Takasaki, M
    Horimi, T
    Ozawa, Z
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (03) : 230 - 233
  • [9] The different forms of the left brachiocephalic vein visualised during cardiovascular implantable electronic device implantation procedures
    Steckiewicz, R.
    Stolarz, P.
    Lange, B.
    FOLIA MORPHOLOGICA, 2023, 82 (01) : 127 - 136
  • [10] Institutional Variation in Quality of Cardiovascular Implantable Electronic Device Implantation A Cohort Study
    Ranasinghe, Isuru
    Labrosciano, Clementine
    Horton, Dennis
    Ganesan, Anand
    Curtis, Jeptha P.
    Krumholz, Harlan M.
    McGavigan, Andrew
    Hossain, Sadia
    Air, Tracy
    Hariharaputhiran, Saranya
    ANNALS OF INTERNAL MEDICINE, 2019, 171 (05) : 309 - +