Evaluation of two rapid screening assays for detecting hepatitis C antibodies in resource-constrained settings

被引:17
|
作者
Kosack, Cara S. [1 ]
Nick, Sigrid [2 ]
机构
[1] Med Sans Frontieres, Plantage Middenlaan 14, NL-1018 DD Amsterdam, Netherlands
[2] Paul Ehrlich Inst, Langen, Germany
关键词
hepatitis C virus; rapid diagnostic test (RDT); point-of-care; OraQuick; Multisure; rapid diagnostic; VIRUS EPIDEMIOLOGY; GLOBAL EPIDEMIOLOGY; TRANSFUSION; INFECTIONS;
D O I
10.1111/tmi.12688
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
ObjectiveTo evaluate the diagnostic accuracy of the OraQuick HCV rapid antibody test from OraSure and the Multisure HCV antibody assay from MP Biomedicals. MethodsFive seropanels from patients, intravenous drug users and blood donors with and without HCV infection were used on the two rapid immunochromatographic tests. Sensitivity, specificity and predictive values were calculated. In addition, seropanels from 10 seroconverters were used to assess early identification of HCV infection. The study was undertaken in a laboratory at Paul Ehrlich Institute in Germany. ResultsPanel 1 contained of 55 positive and 25 negative samples. The OraQuick HCV test had a sensitivity of 100% (95% CI: 93.5-100) and a specificity of 100% (95% CI: 86.3-100). The Multisure HCV test had a sensitivity of 100% (95% CI: 93.5-100) and a specificity of 96% (95% CI: 79.6-99.9). Panel 2 consisted of 193 pre-characterised anti-HCV-positive patient samples. The OraQuick HCV test identified 191 samples correctly and the Multisure HCV 192. The sensitivity was 99.0% (95% CI: 96.3-99.9) for the OraQuick HCV test and 99.5% (95% CI: 97.1-100) for the Multisure HCV test. Panel 3 was composed of seroconversion samples of 10 patients. The OraQuick HCV test detected all of these 10 infections while the Multisure HCV test detected six and was indeterminate on 2. Panel 4 included 53 anti-HCV negative blood samples from blood donors. Both tests correctly identified all 53. Panel 5 consisted of 26 samples of HCV/HIV co-infected patients. The sensitivity of the OraQuick HCV test was 65.2% (95% CI: 42.8-82.8) after 20 min and 73.9% (95% CI: 51.3-88.9) after 40 min of incubation. The Multisure HCV test had a sensitivity of 96.2% (95% CI: 80.4-99.9). ConclusionThis evaluation revealed good sensitivity for both rapid screening assays. The detection of seroconverters, however, was lower in the MutiSure HCV test. Therefore the MultiSure test should be used with hesitation in high incidence settings. The OraQuick gave HCV false-negative results in almost 25% of the HIV-positive sera. Therefore may the OraQuick be less suited in HIV prevalent areas.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 50 条
  • [1] Simplifying hepatitis C service delivery in resource-constrained settings
    Tucker, Joseph D.
    Wu, Dan
    Easterbrook, Philippa
    LANCET GASTROENTEROLOGY & HEPATOLOGY, 2021, 6 (05): : 339 - 340
  • [2] Evaluation of Three Rapid Screening Assays for Detection of Antibodies to Hepatitis C Virus
    Smith, Bryce D.
    Drobeniuc, Jan
    Jewett, Amy
    Branson, Bernard M.
    Garfein, Richard S.
    Teshale, Eyasu
    Kamili, Saleem
    Weinbaum, Cindy M.
    JOURNAL OF INFECTIOUS DISEASES, 2011, 204 (06): : 825 - 831
  • [3] Performance evaluation of three rapid screening assays for detection of antibodies to hepatitis C virus in Cameroon
    Fondjo C.L.K.
    Ngoupo P.A.T.
    Ngono L.
    Plantier J.-C.
    Njouom R.
    BMC Research Notes, 11 (1)
  • [4] Screening for childhood hearing impairment in resource-constrained settings: Opportunities and possibilities
    Petersen, Lucretia
    Ramma, Lebogang
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2015, 105 (11): : 901 - 902
  • [5] AVIVA: a telehealth tool to improve cervical cancer screening in resource-constrained settings
    Ogunsola, Olabanjo Okunlola
    Olawepo, John Olajide
    Ajayi, Oluseye
    Osayi, Emmanuel
    Akinro, Yewande Toluwabori
    Ifechelobi, Chukwuemeka
    Chigbu, Chibuike
    Okonkwo, Prosper
    Ezeanolue, Echezona Edozie
    BMJ GLOBAL HEALTH, 2023, 8 (07):
  • [6] Referral Criteria for Preschool Hearing Screening in Resource-Constrained Settings: A Comparison of Protocols
    Eksteen, Susan
    Eikelboom, Robert H.
    Launer, Stefan
    Kuper, Hannah
    Swanepoel, De Wet
    LANGUAGE SPEECH AND HEARING SERVICES IN SCHOOLS, 2021, 52 (03) : 868 - 876
  • [7] Use of capillary blood glucose for screening for gestational diabetes mellitus in resource-constrained settings
    Bhavadharini, Balaji
    Mahalakshmi, Manni Mohanraj
    Maheswari, Kumar
    Kalaiyarasi, Gunasekaran
    Anjana, Ranjit Mohan
    Deepa, Mohan
    Ranjani, Harish
    Priya, Miranda
    Uma, Ram
    Usha, Sriram
    Pastakia, Sonak D.
    Malanda, Belma
    Belton, Anne
    Unnikrishnan, Ranjit
    Kayal, Arivudainambi
    Mohan, Viswanathan
    ACTA DIABETOLOGICA, 2016, 53 (01) : 91 - 97
  • [8] IMPLEMENTATION AND EVALUATION OF AN MHEALTH SYSTEM FOR ACUTE BURN INJURIES IN RESOURCE-CONSTRAINED SETTINGS
    Hasselberg, Marie
    Wallis, Lee
    Sawe, Hendry
    Laflamme, Lucie
    INJURY PREVENTION, 2016, 22 : A113 - A113
  • [9] Cytomegalovirus retinitis associated with HIV in resource-constrained settings: systematic screening and case detection
    Pathai, Sophia
    Lawn, Stephen D.
    Gilbert, Clare
    INTERNATIONAL HEALTH, 2012, 4 (02): : 86 - 94
  • [10] Screening for HIP and Postpartum follow-up; a major challenge in resource-constrained settings
    Masood, S. N.
    Balaji, B.
    Masood, Y.
    Nasir, S. Ahmad
    Jabeen, S.
    Kabir, S. K.
    Memon, J. M. A.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 197