Retinoscopy/autorefraction:: Which is the best starting point for a noncycloplegic refraction?

被引:0
|
作者
Jorge, J
Queirós, A
Almeida, JB
Parafita, MA
机构
[1] Univ Minho, Sch Sci, Dept Phys Optometry, P-4710057 Braga, Portugal
[2] Univ Santiago de Compostela, Sch Opt & Optometry, Dept Surg Ophthalmol, Santiago, Spain
关键词
refraction; refractive error; accuracy; automated refractor; retinoscopy; subjective refraction; orthogonal functions; astigmatism;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A, Gamagori, Japan) and retinoscopy with subjective refraction. Methods. Measurements of autorefraction obtained with the ARK700A and retinoscopy were performed on 192 right eyes from 192 healthy young adults and compared with subjective refraction. These measurements were performed without cycloplegia. The age range was 18 to 34 years, with a mean value of 21.6 years and an SD of 2.66 years. Results. A comparison of the autorefractor and subjective refraction results shows that (1) for the mean spherical equivalent (M), the autorefractor yields more negative values (-0.44 +/- 0.54 D; p = 0.000); (2) for the Jackson cross-cylinder at axis 0degrees (J(0)), the autorefractor yields more positive values than the subjective ones (0.05 +/- 0.13 D; p = 0.000); and (3) for the Jackson cross-cylinder at axis 45degrees (J(45)), the autorefractor results are more negative (-0.02 +/- 0.09 D; p = 0.019). The differences found for each component M, J(0), and J(45) are statistically significant. By comparing retinoscopy with the subjective examination, there are no statistically significant differences found for the M component (-0.02 +/- 0.33 D; p = 0.304). For the J(0) and J(45) components, the differences are statistically significant (0.07 +/- 0.10 D, p = 0.000; -0.01 +/- 0.08 D, p = 0.008). Conclusions. The present results confirm that when performed by an experienced clinician, retinoscopy is more accurate than automatic refraction, giving a better starting point to noncycloplegic refraction.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 27 条
  • [1] Comparison of Cycloplegic refraction between Retinoscopy, Closed field and Open field autorefraction in Pseudomyopia
    Huaindeen, Jameel Rizwana
    Ramani, Krishna Kumar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Manifest refraction versus autorefraction for measuring best-corrected visual acuity
    Orr, PR
    Cramer, L
    Hawkins, BS
    Bressler, NM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4533 - 4533
  • [3] Comparisons of objective and subjective refraction with and without cycloplegia using binocular wavefront optometer with autorefraction and retinoscopy in school-age children
    Yadi Lei
    Xun Chen
    Mingrui Cheng
    Boliang Li
    Yinjie Jiang
    Yilin Xu
    Xiaoying Wang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1465 - 1472
  • [4] Comparisons of objective and subjective refraction with and without cycloplegia using binocular wavefront optometer with autorefraction and retinoscopy in school-age children
    Lei, Yadi
    Chen, Xun
    Cheng, Mingrui
    Li, Boliang
    Jiang, Yinjie
    Xu, Yilin
    Wang, Xiaoying
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (05) : 1465 - 1472
  • [5] Autorefraction, Retinoscopy, Java']Javal's Rule, and Grosvenor's Modified Java']Javal's Rule: The Best Predictor of Refractive Astigmatism
    Asiedu, Kofi
    Kyei, Samuel
    Ampiah, Emmanuel Ekow
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [6] WHICH SKIN MARKING SYSTEM GIVES THE BEST STARTING POINT WHEN TREATING BREAST CANCER PATIENTS?
    Schouboe, A.
    Andersen, M. H.
    Thomsen, M. S.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S562 - S562
  • [7] Starting a Business: Which Entity Structure Is Best for You?
    Gaff, Brian M.
    Fryzel, Karl P.
    COMPUTER, 2012, 45 (10) : 10 - 12
  • [8] Best starting point to comprehensive process safety education
    Ferjencik, Milos
    PROCESS SAFETY PROGRESS, 2007, 26 (03) : 195 - 202
  • [9] Which Is the Best Laser for Lithotripsy? The Referee Point of View
    Giusti, Guido
    Pupulin, Matheus
    Proietti, Silvia
    EUROPEAN UROLOGY OPEN SCIENCE, 2022, 44 : 20 - 22
  • [10] The best approximation of functions which possess a single essential point.
    Bernstein, S
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1923, 177 : 99 - 101