Evaluation on Models of Energy Efficient Retrofitting for Existing Residential Buildings in North China Based on AHP-FUZZY Method

被引:0
|
作者
Zeng Di [1 ]
Lai Ming [1 ]
Yin Shuai [1 ]
机构
[1] Beijing Jiaotong Univ, Sch Econ & Management, Beijing, Peoples R China
关键词
existing residential buildings; energy efficient retrofitting; AHP-fuzzy method;
D O I
暂无
中图分类号
F8 [财政、金融];
学科分类号
0202 ;
摘要
The energy efficient retrofitting for existing residential buildings was started in Northern areas of China Since 2008, and it has got great achievements in some provinces. Many retrofitting models were created. According to the analysis on these completed retrofitting cases, we wanted to know the main influence factors of the energy efficient retrofit, and how to choice retrofitting model. In order to evaluate each prototype, first, an index system for the choice of energy efficient retrofitting model was created, and the weights of each index were worked out by using analytic hierarchy process (AHP). Second, an evaluation model was developed with the fuzzy comprehensive evaluation method. The result indicated the feasibility of the each retrofitting model.
引用
收藏
页码:844 / 848
页数:5
相关论文
共 50 条
  • [1] Research on energy efficient retrofitting of China existing residential buildings
    Xu, G
    Wang, YW
    PROCEEDINGS OF THE 2004 INTERNATIONAL CONFERENCE ON CONSTRUCTION & REAL ESTATE MANAGEMENT, 2004, : 403 - 406
  • [2] Research on Impact Factor of Existing Residential Buildings Energy-efficient Retrofitting of North China
    Zeng, D.
    Lai, M.
    Yin, S.
    CRIOCM2009: INTERNATIONAL SYMPOSIUM ON ADVANCEMENT OF CONSTRUCTION MANAGEMENT AND REAL ESTATE, VOLS 1-6, 2009, : 285 - 293
  • [3] Enterprise Electric Energy Efficiency Evaluation based on AHP-Fuzzy Method
    Zhang, Y.
    Bai, C. F.
    Han, X. Y.
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 2856 - 2860
  • [4] AHP-Fuzzy Evaluation on Financing Bottleneck in Energy Performance Contracting in China
    Li, Yan
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 121 - 126
  • [5] Strategy of Transformation on Existing Residential Buildings for Energy Saving in the North of China
    Wang, Xueying
    Xu, Dong
    Wu, Yajun
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3354 - 3357
  • [6] Synthetic evaluation of integrated energy system based on AHP-fuzzy comprehensive assessment method
    Lu, Xiao
    Wu, Jiajia
    Hu, Wei
    Chi, Changyun
    Jiang, Xuedong
    Li, Xiaobo
    2020 INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND BIOENGINEERING (ICEEB 2020), 2020, 185
  • [7] Evaluation of autogenous shrinkage of HPC based on AHP-fuzzy method
    Li, Yue
    Guo, Yi-Lin
    Huo, Da
    Beijing Gongye Daxue Xuebao / Journal of Beijing University of Technology, 2007, 33 (09): : 931 - 936
  • [8] Competitiveness Evaluation of China Chain Retail Enterprises Based on AHP-FUZZY
    Wang, Chongcai
    Zhang, Mingli
    Tu, Jianbo
    2013 IEEE INTERNATIONAL CONFERENCE ON SERVICE OPERATIONS AND LOGISTICS, AND INFORMATICS (SOLI), 2013, : 160 - 165
  • [9] Operation performance evaluation of green public buildings with AHP-fuzzy synthetic assessment method based on cloud model
    Zhou, Yan
    Cai, Jianmin
    Xu, Yiwen
    Wang, Yihui
    Jiang, Chao
    Zhang, Qiuqi
    JOURNAL OF BUILDING ENGINEERING, 2021, 42
  • [10] Research on Issues of Existing Residential Buildings Energy-Efficient Retrofitting during China's "Twelfth Five-Year" Period
    Zeng Di
    Yin Shuai
    Liu Yisheng
    ECONOMICS AND FINANCE RESEARCH, 2011, 4 : 86 - 89