Sensor for hydrogen peroxide based on Prussian Blue modified electrode: Improvement of the operational stability

被引:56
|
作者
de Mattos, IL
Gorton, L
Ruzgas, T
Karyakin, AA
机构
[1] UNESP, Fac Ciencias, Dept Quim, BR-17033360 Bauru, SP, Brazil
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 117234, Russia
关键词
D O I
10.2116/analsci.16.795
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Improvement of the operational stability of amperometric sensors based on Prussian Blue (PB) modified glassy carbon electrodes is presented. The long term performance of the sensors was evaluated by injection of hydrogen peroxide (5 mu M in potassium buffer) solutions in a flow-injection system during a period of 5 - 10 h. The following parameters were investigated and correlated with the performance of the sensor: the times for electrodeposition and electrochemical activation, temperature, storage time, pH, composition of the buffer solution and of volume sample injected. These analytical characteristics of the modified electrode can be emphasized: initial sensitivity of 0.3 A cm(-2) M-1, detection limit of cn. 0.5 mu M, precise results (r.s.d.< 1.5%) and possibility to carry out around 50 samples (50 mu L) per hour.
引用
收藏
页码:795 / 798
页数:4
相关论文
共 50 条
  • [1] Sensor for Hydrogen Peroxide Based on Prussian Blue Modified Electrode: Improvement of the Operational Stability
    Ivanildo Luiz de Mattos
    Lo Gorton
    Tautgirdas Ruzgas
    Arkady A. Karyakin
    Analytical Sciences, 2000, 16 : 795 - 798
  • [2] A HYDROGEN PEROXIDE SENSOR BASED ON PRUSSIAN BLUE AND DNA-MODIFIED ELECTRODE
    Ma, Xiuju
    Yin, Guang
    Yang, Xiao
    Wan, Jun
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (05) : 490 - 499
  • [3] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Yonghong Li
    Xiaoying Liu
    Xiandong Zeng
    Yong Liu
    Xinsheng Liu
    Wanzhi Wei
    Shenglian Luo
    Microchimica Acta, 2009, 165 : 393 - 398
  • [4] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Li, Yonghong
    Liu, Xiaoying
    Zeng, Xiandong
    Liu, Yong
    Liu, Xinsheng
    Wei, Wanzhi
    Luo, Shenglian
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 393 - 398
  • [5] A sensitivity-controlled hydrogen peroxide sensor based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Jin, Wanqin
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (02) : 484 - 487
  • [6] Exploring Electrochemistry: A Hydrogen Peroxide Sensor Based on a Screen-Printed Carbon Electrode Modified with Prussian Blue
    Todorov, Jovica
    McCarty, Gregory S.
    Sombers, Leslie A.
    JOURNAL OF CHEMICAL EDUCATION, 2023, 100 (12) : 4853 - 4859
  • [7] Non-enzyme Sensor for Hydrogen Peroxide Based on Prussian Blue/Manganese Dioxide Composite Modified Electrode
    Liu Yu-Ge
    Li Zhi-Guo
    Chen Wei-Zhen
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2020, 36 (03) : 421 - 425
  • [8] A New Hydrogen Peroxide Sensor Based on Prussian Blue Modified n-n+-Si Photo-Electrode
    Li, Huaixiang
    Ban, Yanping
    Gao, Qi
    Wei, Qingqing
    INTEGRATED FERROELECTRICS, 2012, 135 : 110 - 118
  • [9] Hydrogen peroxide sensor based on electrodeposited Prussian blue film
    Lu, Si-Yuan
    Chen, Yihao
    Fang, Xufei
    Feng, Xue
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2017, 47 (11) : 1261 - 1271
  • [10] Hydrogen peroxide sensor based on electrodeposited Prussian blue film
    Si-Yuan Lu
    Yihao Chen
    Xufei Fang
    Xue Feng
    Journal of Applied Electrochemistry, 2017, 47 : 1261 - 1271