CORROSION BEHAVIOUR OF ELECTROPOLISHED IMPLANT ALLOYS

被引:0
|
作者
Munroe, Norman [1 ]
Haider, Waseem [1 ]
Datye, Amit [2 ]
Wu, Kuang-His [2 ]
机构
[1] Florida Int Univ, Appl Res Ctr, Miami, FL 33199 USA
[2] Florida Int Univ, Dept Mech & Mat Engn, Miami, FL 33199 USA
关键词
corrosion; cyclic polarization; cardiovascular stents; nitinol; pitting; biocompatibility;
D O I
10.1361/cp2007smst307
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Most medical device alloys are electropolished prior to implantation and are immediately protected by the formation of passivating metal oxides. Nevertheless, tissue and fluid present in the human body presents a very corrosive environment to metals once implanted. This is exacerbated by the effects of strain, fatigue, abrasion or wear, which may rupture the passive film exposing the underlying metal. Cyclic potentiodynamic polarization studies were conducted to compare the corrosion resistance of Nitinol and stainless steel cardiovascular stents. In an attempt to simulate their corrosion behavior under body conditions, a Phosphate Buffered Saline (PBS) solution at 37 degrees C was employed utilizing the ASTM F2129-01, Item 2, WK1749, Standard [1]. The results of this study indicate that both materials exhibit high corrosion resistance in the PBS solution with stainless steel exhibiting slightly better corrosion resistance. However, electropolished nitinol stents appeared to have better corrosion resistance as compared to the unpolished ones.
引用
收藏
页码:307 / +
页数:2
相关论文
共 50 条
  • [1] Corrosion behaviour of electropolished magnesium materials
    Kloiber, Jessica
    Schultheiss, Ulrich
    Sotelo, Lamborghini
    Sarau, George
    Christiansen, Silke
    Gavras, Sarkis
    Hort, Norbert
    Hornberger, Helga
    MATERIALS TODAY COMMUNICATIONS, 2024, 38
  • [2] Behaviour of zinc in electropolished and etched Al-Zn alloys and effect on corrosion potential
    Arenas, MA
    Iglesias-Rubianes, L
    Liu, Y
    Skeldon, P
    Thompson, GE
    Habazaki, H
    Shimizu, K
    Bailey, P
    Noakes, TCQ
    CORROSION SCIENCE, 2005, 47 (09) : 2321 - 2331
  • [3] Electrochemical corrosion behaviour of dental/implant alloys in saline medium
    Sharma, Mohit
    Kumar, A. V. Ramesh
    Singh, Nirbhay
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (07) : 2647 - 2653
  • [4] Electrochemical corrosion behaviour of dental/implant alloys in saline medium
    Mohit Sharma
    A. V. Ramesh Kumar
    Nirbhay Singh
    Journal of Materials Science: Materials in Medicine, 2008, 19 : 2647 - 2653
  • [5] Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys
    Fleck, Claudia
    Eifler, Dietmar
    INTERNATIONAL JOURNAL OF FATIGUE, 2010, 32 (06) : 929 - 935
  • [6] On the Corrosion Behaviour of Low Modulus Titanium Alloys for Medical Implant Applications: A Review
    Afzali, Pooria
    Ghomashchi, Reza
    Oskouei, Reza H.
    METALS, 2019, 9 (08)
  • [7] In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application
    Xu, Liping
    Zhang, Erlin
    Yin, Dongsong
    Zeng, Songyan
    Yang, Ke
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (03) : 1017 - 1025
  • [8] In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application
    Liping Xu
    Erlin Zhang
    Dongsong Yin
    Songyan Zeng
    Ke Yang
    Journal of Materials Science: Materials in Medicine, 2008, 19 : 1017 - 1025
  • [9] INVITRO CREVICE CORROSION OF IMPLANT ALLOYS
    SUTOW, EJ
    JONES, DW
    MILNE, T
    JOURNAL OF DENTAL RESEARCH, 1977, 56 : B79 - B79
  • [10] Corrosion behaviour of electropolished AISI 316L austenitic biomaterial in physiological solution
    Zatkalikova, V.
    Markovicova, L.
    Skorvanova, M.
    27TH JOINT SEMINAR DEVELOPMENT OF MATERIALS SCIENCE IN RESEARCH AND EDUCATION, 2017, 266