Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems)

被引:49
|
作者
Tadano, Shigeru [1 ]
Takeda, Ryo [1 ]
Sasaki, Keita [2 ]
Fujisawa, Tadashi [2 ]
Tohyama, Harukazu [3 ]
机构
[1] Hokkaido Univ, Fac Engn, Div Human Mech Syst & Design, North 13,West 8, Sapporo, Hokkaido 060, Japan
[2] Hokkaido Univ, Grad Sch Engn, Div Human Mech Syst & Design, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Fac Hlth Sci, Sapporo, Hokkaido, Japan
关键词
Osteoarthritis; Three dimensional gait analysis; Acceleration sensor; Gyro sensor; Kinematic gait parameters; Spatio-temporal gait parameters; ORIENTATION; ANGLE; ACCELERATION; GYROSCOPES; ACCURACY; TRACKING; WALKING;
D O I
10.1016/j.jbiomech.2016.01.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objective of this work was to investigate the possibilities of using the wearable sensors-based H-Gait system in an actual clinical trial and proposes new gait parameters for characterizing OA gait. Seven H-Gait sensors, consisting of tri-axial inertial sensors, were attached to seven lower limb body segments (pelvis, both thighs, both shanks and both feet). The acceleration and angular velocity data measured were used to estimate three-dimensional kinematic parameters of patients during level walking. Three new parameters were proposed to assess the severity of OA based on the characteristics of these joint center trajectories in addition to conventional gait spatio-temporal parameters. The experiment was conducted on ten subjects with knee OA. The kinematic results obtained (hip, knee and ankle joint angles, joint trajectory in the horizontal and sagittal planes) were compared with those from a reference healthy (control) group. As a result, the angle between the right and left knee trajectories along with that of the ankle joint trajectories were almost twice as large (21.3 degrees vs. 11.6 degrees and 14.9 degrees vs. 7.8 degrees) compared to those of the healthy subjects. In conclusion, it was found that the ankle joints during stance abduct less to avoid adduction at the knee as the severity of OA increases and lead to more acute angles (less parallel) between the right and left knee/ankle joints in the horizontal plane. This method was capable to provide quantitative information about the gait of OA patients and has the advantage to allow for out-of laboratory monitoring. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:684 / 690
页数:7
相关论文
共 50 条
  • [1] Reliability of gait analysis using wearable sensors in patients with knee osteoarthritis
    Kobsar, Dylan
    Osis, Sean T.
    Phinyomark, Angkoon
    Boyd, Jeffrey E.
    Ferber, Reed
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3977 - 3982
  • [2] Measuring gait kinematics in patients with severe hip osteoarthritis using wearable sensors
    Ismailidis, Petros
    Nuesch, Corina
    Kaufmann, Mara
    Clauss, Martin
    Pagenstert, Geert
    Eckardt, Anke
    Ilchmann, Thomas
    Mundermann, Annegret
    [J]. GAIT & POSTURE, 2020, 81 : 49 - 55
  • [3] Gait Analysis Using Wearable Sensors
    Tao, Weijun
    Liu, Tao
    Zheng, Rencheng
    Feng, Hutian
    [J]. SENSORS, 2012, 12 (02) : 2255 - 2283
  • [4] Gait Analysis Using Wearable Sensors
    Bhosale, Tanmav
    Kudale, Hemant
    Kumthekar, Varun
    Garude, Shreyash
    Dhumal, Prasad
    [J]. 2015 INTERNATIONAL CONFERENCE ON ENERGY SYSTEMS AND APPLICATIONS, 2015, : 267 - 269
  • [5] Gait, freezing of gait and falls detection using wearable sensors: A systematic review
    Lima, A. L. Silvade
    Evers, L. J. W.
    Hahn, T.
    Bataille, L.
    Hamilton, J. L.
    Little, M. A.
    Bloem, B. R.
    Faber, M. J.
    [J]. MOVEMENT DISORDERS, 2017, 32
  • [6] Gait Variability to Phenotype Common Orthopedic Gait Impairments Using Wearable Sensors
    Kushioka, Junichi
    Sun, Ruopeng
    Zhang, Wei
    Muaremi, Amir
    Leutheuser, Heike
    Odonkor, Charles A.
    Smuck, Matthew
    [J]. SENSORS, 2022, 22 (23)
  • [7] Evaluation of gait characteristics in subjects with locomotive syndrome using wearable gait sensors
    Yuki Saito
    Tomoya Ishida
    Yoshiaki Kataoka
    Ryo Takeda
    Shigeru Tadano
    Teppei Suzuki
    Kentaro Nakamura
    Akimi Nakata
    Satoshi Osuka
    Satoshi Yamada
    Mina Samukawa
    Harukazu Tohyama
    [J]. BMC Musculoskeletal Disorders, 23
  • [8] Evaluation of gait characteristics in subjects with locomotive syndrome using wearable gait sensors
    Saito, Yuki
    Ishida, Tomoya
    Kataoka, Yoshiaki
    Takeda, Ryo
    Tadano, Shigeru
    Suzuki, Teppei
    Nakamura, Kentaro
    Nakata, Akimi
    Osuka, Satoshi
    Yamada, Satoshi
    Samukawa, Mina
    Tohyama, Harukazu
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [9] Irregular Gait Detection using Wearable Sensors
    Lydakis, Andreas
    Kao, Pei-Chun
    Begum, Momotaz
    [J]. 10TH ACM INTERNATIONAL CONFERENCE ON PERVASIVE TECHNOLOGIES RELATED TO ASSISTIVE ENVIRONMENTS (PETRA 2017), 2017, : 150 - 155
  • [10] Gait Analysis using Wearable Sensors with Multiple Sclerosis Patients
    Jurisic Skevin, Aleksandra
    Filipovic, Nenad
    Mijailovic, Nikola
    Divjak, Ana
    Nurkovic, Jasmin
    Radakovic, Radivoje
    Gacic, Marija
    Grbovic, Vesna
    [J]. TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2018, 25 : 339 - 342