Distributions of air temperature and pressure across a cross section of a full-scale passively aerated compost pile were measured as a function of time over an 11 day long period covering two pile turnings. The compost pile was 1.8 m high, 4.4 m wide, 80 m long and consisted of sewage sludge, yard/park waste and screening residue from previously composted materials. The measurements were conducted in one cross section of the pile. The temperature and pressure data were used in combination with additional measurements of air permeability in the compost pile to calculate air fluxes in and out of the pile as well as internally in the pile. Temperature distributions were generally constant with time while pressure and air flux had greater variability. The results suggested that steady state conditions in the compost between turnings with respect to air flow are not necessarily achieved. Air flow rates in or out of the compost pile were up to 50 Nm(3)m(-2)h(-1) and the average passive air supply to the compost pile over the experimental period was on the order of 4 m(3)m(-3) compost h(-1).
引用
收藏
页码:127 / 134
页数:8
相关论文
共 50 条
  • [1] Temperature, pressure and air flow distribution in passively aerated compost piles
    Poulsen T.G.
    Compost Science and Utilization, 2010, 18 (02): : 127 - 134
  • [2] TEMPERATURE DISTRIBUTION AND VARIATION IN PASSIVELY AERATED STATIC COMPOST PILES
    FERNANDES, L
    ZHAN, W
    PATNI, NK
    JUI, PY
    BIORESOURCE TECHNOLOGY, 1994, 48 (03) : 257 - 263
  • [4] Design of passively aerated compost piles: Vertical air velocities between the pipes
    Lynch, NJ
    Cherry, RS
    BIOTECHNOLOGY PROGRESS, 1996, 12 (05) : 624 - 629
  • [5] Estimation of vertical air flow in passively aerated compost in a cylindrical bioreactor
    Yu, S.
    Clark, O.G.
    Leonard, J.J.
    Canadian Biosystems Engineering / Le Genie des biosystems au Canada, 2008, 50 : 29 - 6
  • [6] Influence of free air space on microbial kinetics in passively aerated compost
    Yu, Shouhai
    Clark, O. Grant
    Leonard, Jerry J.
    BIORESOURCE TECHNOLOGY, 2009, 100 (02) : 782 - 790
  • [7] AN AIR-FLOW DIRECTIONAL VALVE FOR AERATED COMPOST SYSTEMS
    HIGGINS, AJ
    TRANSACTIONS OF THE ASAE, 1984, 27 (02): : 541 - 544
  • [8] Modelling air flow and ambient temperature effects on the biological self-heating of compost piles
    Luangwilai, T.
    Sidhu, H. S.
    Nelson, M. I.
    Chen, X. D.
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2010, 5 (04) : 609 - 618
  • [9] Characterization and spatial distribution of bacterial communities within passively aerated cattle manure composting piles
    Maeda, Koki
    Hanajima, Dai
    Morioka, Riki
    Osada, Takashi
    BIORESOURCE TECHNOLOGY, 2010, 101 (24) : 9631 - 9637
  • [10] AIR CONCENTRATION DISTRIBUTION IN SELF-AERATED FLOW
    CHANSON, H
    JOURNAL OF HYDRAULIC RESEARCH, 1995, 33 (04) : 586 - 588