Once reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues. Retrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique. For the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDIvol was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDIvol was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001). Both cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 50 条
  • [1] Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation
    James C. McEachen
    Shuai Leng
    Thomas D. Atwell
    Matthew K. Tollefson
    Jeremy L. Friese
    Zhen Wang
    M. Hassan Murad
    Grant D. Schmit
    [J]. CardioVascular and Interventional Radiology, 2016, 39 : 233 - 238
  • [2] Percutaneous ablation of renal tumors: Radiofrequency ablation or cryoablation?
    Buy, X.
    Lang, H.
    Garnon, J.
    Gangi, A.
    [J]. JOURNAL DE RADIOLOGIE, 2011, 92 (09): : 774 - 788
  • [3] Cost analysis for four techniques of renal tumor ablation: Laparoscopic and percutaneous radiofrequency ablation and cryoablation
    Park, S
    Dusseault, BN
    Lotan, Y
    Pattaras, J
    Ogan, K
    [J]. JOURNAL OF UROLOGY, 2006, 175 (04): : 340 - 341
  • [4] Cost analysis for four techniques of renal tumor ablation: Laparoscopic and percutaneous radiofrequency ablation and cryoablation.
    Park, Sangtae
    Zeltser, Ilia
    Dusseault, Beau
    Lotan, Yair
    Pattaras, John G.
    Ogan, Kenneth
    [J]. JOURNAL OF ENDOUROLOGY, 2006, 20 : A7 - A7
  • [5] Cryoablation versus Radiofrequency Ablation for Renal Tumor Ablation: Time to Reassess?
    Gervais, Debra A.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (08) : 1135 - 1138
  • [6] Hepatic hemorrhage caused by percutaneous tumor ablation: Radiofrequency ablation versus cryoablation in a porcine model
    Shock, SA
    Laeseke, PF
    Sampson, LA
    Lewis, WD
    Winter, TC
    Fine, JP
    Lee, FT
    [J]. RADIOLOGY, 2005, 236 (01) : 125 - 131
  • [7] RADIATION DOSES RECEIVED DURING RADIOFREQUENCY ABLATION AND CRYOABLATION TREATMENT OF SMALL RENAL TUMORS
    Schroeder, Gabriel T.
    Richards, Gideon D.
    Agarwal, Gautum
    Smith, Damien L.
    Heldt, Jonathan P.
    Penkar, Miriam
    Arnold, Don C., II
    Smith, Jason C.
    Baldwin, D. Duane
    [J]. JOURNAL OF ENDOUROLOGY, 2011, 25 : A134 - A134
  • [8] Probe ablation for renal tumors: Comparison of cryoablation and radiofrequency ablation
    Hegarty, NJ
    Kaouk, JH
    Remer, E
    O'Malley, CM
    Desai, MM
    Gill, LS
    Novick, AC
    [J]. JOURNAL OF UROLOGY, 2006, 175 (04): : 26 - 26
  • [9] Pain control requirements for percutaneous ablation of renal tumors: Cryoablation versus radiofrequency ablation - Initial observations
    Allaf, ME
    Varkarakis, IM
    Bhayani, SB
    Inagaki, T
    Kavoussi, LR
    Solomon, SB
    [J]. RADIOLOGY, 2005, 237 (01) : 366 - 370
  • [10] Percutaneous tumor ablation with radiofrequency
    Wood, BJ
    Ramkaransingh, JR
    Fojo, T
    Walther, MM
    Libutti, SK
    [J]. CANCER, 2002, 94 (02) : 443 - 451