Initial value of step response for lossy nonuniform transmission lines

被引:0
|
作者
Sekine, T [1 ]
Kobayashi, K [1 ]
机构
[1] Gifu Univ, Dept Elect & Elect Engn, Gifu 5011193, Japan
来源
2002 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS | 2002年
关键词
D O I
10.1109/ICMMT.2002.1187863
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An exact solution of the initial value of step responce for lossy nonuniform transmission line is derived. Initial value of the near end responce is no influenced by the transmission line loss and if the change in the characteristic impedance is continuous, initial value of the far end response is decided without any relation to the distribution of the characteristic impedance are described.
引用
收藏
页码:962 / 965
页数:4
相关论文
共 50 条
  • [1] Analysis of Coupled Nonuniform Transmission Lines as an Initial Value Problem
    Khalaj-Amirhosseini, Mohammad
    PIERS 2010 CAMBRIDGE: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2010, : 150 - 153
  • [2] Sensitivity analysis of parabolic lossy nonuniform transmission lines
    Liang, GS
    Xu, ZH
    Dong, HY
    Ji, CH
    IEEE 2005 International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications Proceedings, Vols 1 and 2, 2005, : 823 - 826
  • [3] EQUIVALENT REPRESENTATIONS OF LOSSY NONUNIFORM TRANSMISSION-LINES
    ENDO, I
    NEMOTO, Y
    SATO, R
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1983, 31 (06) : 457 - 462
  • [4] Spectral Models of Lossy Nonuniform Multiconductor Transmission Lines
    Antonini, Giulio
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2012, 54 (02) : 474 - 481
  • [5] A precise time-step integration method for transient analysis of lossy nonuniform transmission lines
    Tang, Min
    Mao, Junfa
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2008, 50 (01) : 166 - 174
  • [6] Transient analysis of lossy nonuniform transmission lines using a time-step integration method
    Tang, M.
    Mao, J. F.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2007, 69 : 257 - 266
  • [7] TRANSIENT ANALYSIS AND SIMULATION OF NONUNIFORM LOSSY TRANSMISSION-LINES
    BANDURSKI, W
    INTERNATIONAL JOURNAL OF MICROWAVE AND MILLIMETER-WAVE COMPUTER-AIDED ENGINEERING, 1992, 2 (03): : 189 - 202
  • [8] FDTD Analysis of Nonuniform Lossy Cascade Multiconductor Transmission Lines
    付继伟
    侯朝桢
    窦丽华
    Journal of Beijing Institute of Technology(English Edition), 2004, (04) : 373 - 377
  • [9] Transient analysis of nonuniform lossy transmission lines with frequency dependent parameters
    Mamis, MS
    Koksal, M
    ELECTRIC POWER SYSTEMS RESEARCH, 1999, 52 (03) : 223 - 228
  • [10] Sensitivity Analysis of Lossy Nonuniform Multiconductor Transmission Lines With Nonlinear Terminations
    Dou, Lei
    Dou, Jiao
    IEEE TRANSACTIONS ON ADVANCED PACKAGING, 2010, 33 (02): : 492 - 497