Optical considerations for scleral contact lenses: A review

被引:54
|
作者
Vincent, Stephen J. [1 ]
Fadel, Daddi [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room D513,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
来源
CONTACT LENS & ANTERIOR EYE | 2019年 / 42卷 / 06期
关键词
Scleral contact lens; Corneal rigid contact lens; Optics; Prism; Higher order aberrations; Post-lens tear layer; LONGITUDINAL SPHERICAL-ABERRATION; TEAR FILM; CORNEAL CURVATURE; OCULAR SURFACE; KERATOCONUS; WEAR; EYES; REHABILITATION; PERFORMANCE; ASTIGMATISM;
D O I
10.1016/j.clae.2019.04.012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Scleral contact lenses have a range of therapeutic and optical applications. In recent years, scleral lens prescribing has increased due to significant advances in ocular imaging technology, lens manufacturing processes, and the widespread availability of scleral lenses globally. While the optical principles of scleral lenses are identical to those of corneal rigid lenses (i.e. the post-lens tear layer neutralises the majority of anterior corneal astigmatism and higher order aberrations), the nature of scleral lenses and their typical fitting characteristics means that many of the assumptions of 'thin lens' paraxial optics traditionally used for corneal rigid lens calculations may be inappropriate in certain clinical scenarios. This review provides a comprehensive overview of a variety of lens and fitting characteristics that are unique to scleral lenses, or not typically encountered with corneal rigid lenses, and how these factors may potentially influence optical performance based on theoretical modelling, in particular; scleral lens parameters, the post-lens tear layer, and dynamic changes during lens wear. Current front and back surface lens designs and future scleral lens applications are also discussed, along with lens modifications to improve visual outcomes and transient changes in corneal optics induced by appropriately fitted modern scleral lenses.
引用
收藏
页码:598 / 613
页数:16
相关论文
共 50 条
  • [1] Modern scleral contact lenses: A review
    van der Worp, Eef
    Bornman, Dina
    Ferreira, Daniela Lopes
    Faria-Ribeiro, Miguel
    Garcia-Porta, Nery
    Gonzalez-Meijome, Jose M.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (04): : 240 - 250
  • [2] SCLERAL CONTACT LENSES
    TAUB, RG
    EYE EAR NOSE AND THROAT MONTHLY, 1967, 46 (01): : 84 - &
  • [3] SCLERAL CONTACT LENSES
    STONE, W
    GOULD, HL
    ARCHIVES OF OPHTHALMOLOGY, 1964, 71 (04) : 606 - &
  • [4] Scleral Contact Lenses in an Academic Oculoplastics Clinic: Epidemiology and Emerging Considerations
    Chahal, Harinder S.
    Estrada, Marcela
    Sindt, Christine W.
    Boehme, Jacob A.
    Greiner, Mark A.
    Nerad, Jeffrey A.
    Carter, Keith D.
    Allen, Richard C.
    Shriver, Erin M.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2018, 34 (03): : 231 - 236
  • [5] Developments in scleral contact lenses
    不详
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (02) : 109 - 109
  • [6] AN EVALUATION OF SCLERAL CONTACT LENSES
    MACDONALD, D
    INVESTIGATIVE OPHTHALMOLOGY, 1964, 3 (04): : 464 - 464
  • [7] Complications and fitting challenges associated with scleral contact lenses: A review
    Walker, Maria K.
    Bergmanson, Jan P.
    Miller, William L.
    Marsack, Jason D.
    Johnson, Leah A.
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (02): : 88 - 96
  • [8] PHYSIOLOGICAL CONSIDERATIONS IN DESIGN OF INTERNAL AND EXTERNAL SURFACES OF FLUIDLESS SCLERAL CONTACT LENSES
    JESSEN, GN
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1969, 46 (04): : 308 - &
  • [9] Optical coherence tomography and scleral contact lenses: clinical and research applications
    Vincent, Stephen J.
    Alonso-caneiro, David
    Collins, Michael J.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (03) : 224 - 241
  • [10] Scleral contact lenses are not optically inferior to corneal lenses
    Singh, AJ
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1662 - 1663