Optical coherence tomography for differentiation of parathyroid gland tissue

被引:0
|
作者
Ladurner, R. [1 ]
Hallfeldt, K. [1 ]
Al Arabi, N. [1 ]
Gallwas, J. [2 ]
Mortensen, U. [3 ]
Sommerey, S. [1 ]
机构
[1] Klinikum Univ Munchen, Klin Allgemeine Viszeral Transplantat Gefass & Th, Campus Innenstadt,Nussbaumstr 20, D-80336 Munich, Germany
[2] Klinikum Univ Munchen, Klin & Poliklin Frauenheilkunde & Geburtshilfe, Campus Grosshadern, D-81377 Munich, Germany
[3] Univ Munster, Inst Psychol, D-48149 Munster, Germany
来源
CHIRURG | 2016年 / 87卷 / 05期
关键词
Optical coherence tomography; Tissue differentiation; In vivo; Parathyroid surgery; Backscattering intensity; PRIMARY HYPERPARATHYROIDISM; DIAGNOSIS; SURGERY;
D O I
10.1007/s00104-015-0120-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
Optical coherence tomography (OCT) is a high-resolution imaging technique that allows the identification of microarchitectural features in real-time. Can OCT be used to differentiate parathyroid tissue from other cervical tissue entities? All investigations were carried out during cervical operations. Initially, ex vivo images were analyzed to define morphological imaging criteria for each tissue entity. These criteria were used to evaluate a first series of ex vivo images. In a second phase the practicability of the technique was investigated in vivo and in the third phase backscattering intensity measurements were analyzed employing linear discriminant analysis (LDA). In the ex vivo series parathyroid tissue could be differentiated from other tissue entities with a sensitivity and specificity of 84 % and 94 %, respectively. Parathyroid tissue was correctly identified in the in vivo series in only 69.2 %. The analysis of backscattering intensity profiles employing LDA reliably distinguished between the different tissue types. The OCT images displayed typical characteristics for each tissue entity. Due to technical problems in handling the probe the in vivo OCT images were of much poorer quality. Backscattering intensity measurements illustrated that OCT images provide an individual profile for each tissue entity independent of the defined morphological assessment criteria. The results show that OCT is fundamentally suitable for intraoperative differentiation of tissues.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [1] Automated algorithm for breast tissue differentiation in optical coherence tomography
    Mujat, Mircea
    Ferguson, R. Daniel
    Hammer, Daniel X.
    Gittins, Christopher
    Iftimia, Nicusor
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (03)
  • [2] Improved Arterial Tissue Differentiation by Spectroscopic Optical Coherence Tomography
    Flueraru, C.
    Popescu, D. P.
    Mao, Y.
    Chang, S.
    Sowa, M. G.
    Vitkin, A.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2015, 7 (01) : 13 - 19
  • [3] Optische Kohärenztomographie als Verfahren zur Differenzierung von NebenschilddrüsengewebeOptical coherence tomography for differentiation of parathyroid gland tissue
    R. Ladurner
    K. Hallfeldt
    N. Al Arabi
    J. Gallwas
    U. Mortensen
    S. Sommerey
    Der Chirurg, 2016, 87 (5): : 416 - 422
  • [4] Optical coherence tomography imaging during thyroid and parathyroid surgery: A novel system of tissue identification and differentiation to obviate tissue resection and frozen section
    Conti de Freitas, Luiz C.
    Phelan, Eimear
    Liu, Linbo
    Gardecki, Joseph
    Namati, Eman
    Warger, Willian C.
    Tearney, Guillermo J.
    Randolph, Gregory W.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2014, 36 (09): : 1329 - 1334
  • [5] Segmentation of optical coherence tomography images for differentiation of the cavernous nerves from the prostate gland
    Chitchian, Shahab
    Weldon, Thomas P.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (04)
  • [6] Intraoperative Optical Coherence Tomography for Soft Tissue Sarcoma Differentiation and Margin Identification
    Mesa, Kelly J.
    Selmic, Laura E.
    Pande, Paritosh
    Monroy, Guillermo L.
    Reagan, Jennifer
    Samuelson, Jonathan
    Driskell, Elizabeth
    Li, Joanne
    Marjanovic, Marina
    Chaney, Eric J.
    Boppart, Stephen A.
    LASERS IN SURGERY AND MEDICINE, 2017, 49 (03) : 240 - 248
  • [7] Automatic Identification of Parathyroid in Optical Coherence Tomography Images
    Hou, Fang
    Yu, Yang
    Liang, Yanmei
    LASERS IN SURGERY AND MEDICINE, 2017, 49 (03) : 305 - 311
  • [8] Optical Coherence Tomography as a Method to Identify Parathyroid Glands
    Ladurner, Roland
    Hallfeldt, Klaus K. J.
    Al Arabi, Norah
    Stepp, Herbert
    Mueller, Susanna
    Gallwas, Julia K. S.
    LASERS IN SURGERY AND MEDICINE, 2013, 45 (10) : 654 - 659
  • [9] Rapid head and neck tissue identification in thyroid and parathyroid surgery using optical coherence tomography
    Yang, Nathan
    Boudoux, Caroline
    De Montigny, Etienne
    Maniakas, Anastasios
    Gologan, Olga
    Madore, Wendy-Julie
    Khullar, Sharmila
    Guertin, Louis
    Christopoulos, Apostolos
    Bissada, Eric
    Ayad, Tareck
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (12): : 4171 - 4180
  • [10] Method of Tissue Differentiation Based on Changes in Tissue Optical Properties Under Mechanical Stress Estimated with Optical Coherence Tomography
    Sherstnev, Evgeny P.
    Moiseev, Alexander A.
    Sovetsky, Aleksander A.
    Shilyagin, Pavel A.
    Ksenofontov, Sergey Y.
    Gelikonov, Grigory V.
    PHOTONICS, 2025, 12 (02)