RISE AND SHOCK: OPTIMAL DEFIBRILLATOR PLACEMENT IN A HIGH-RISE BUILDING

被引:11
|
作者
Chan, Timothy C. Y. [1 ,2 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, 5 Kings Coll Rd, Toronto, ON M5S 3G8, Canada
[2] St Michaels Hosp, Li Ka Shing Knowledge Inst, Toronto, ON, Canada
关键词
resuscitation; cardiac arrest; public access defibrillator; automated external defibrillator; high-rise building; HOSPITAL CARDIAC-ARREST; AUTOMATED EXTERNAL DEFIBRILLATORS; PUBLIC-ACCESS DEFIBRILLATORS; LOCATIONS; SURVIVAL; RESUSCITATION; OPTIMIZATION; GUIDELINES; BARRIERS; MODEL;
D O I
10.1080/10903127.2016.1247202
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Out-of-hospital cardiac arrests (OHCA) in high-rise buildings experience lower survival and longer delays until paramedic arrival. Use of publicly accessible automated external defibrillators (AED) can improve survival, but "vertical" placement has not been studied. We aim to determine whether elevator-based or lobby-based AED placement results in shorter vertical distance travelled ("response distance") to OHCAs in a high-rise building. Methods: We developed a model of a single-elevator, n-floor high-rise building. We calculated and compared the average distance from AED to floor of arrest for the two AED locations. We modeled OHCA occurrences using floor-specific Poisson processes, the risk of OHCA on the ground floor (lambda(1)) and the risk on any above-ground floor (lambda). The elevator was modeled with an override function enabling direct travel to the target floor. The elevator location upon override was modeled as a discrete uniform random variable. Calculations used the laws of probability. Results: Elevator-based AED placement had shorter average response distance if the number of floors (n) in the building exceeded three quarters of the ratio of ground-floor OHCA risk to above-ground floor risk (lambda(1)/lambda.) plus one half (n >= 3 lambda(1)/4 lambda + 0.5). Otherwise, a lobby-based AED had shorter average response distance. If OHCA risk on each floor was equal, an elevator-based AED had shorter average response distance. Conclusions: Elevator-based AEDs travel less vertical distance to OHCAs in tall buildings or those with uniform vertical risk, while lobby-based AEDs travel less vertical distance in buildings with substantial lobby, underground, and nearby street-level traffic and OHCA risk.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 50 条
  • [1] High-Rise Building Fires
    Kohno, Mamoru
    [J]. JOURNAL OF DISASTER RESEARCH, 2007, 2 (04) : 236 - 249
  • [2] A high-rise building fire
    Craighead, G
    [J]. FOURTH CONFERENCE ON TALL BUILDINGS IN SEISMIC REGIONS, PROCEEDINGS: TALL BUILDINGS FOR THE 21ST CENTURY, 1997, : 427 - 428
  • [3] OPTIMAL DESIGN OF HIGH-RISE BUILDING BUNDLED TUBE SYSTEMS
    Ghasemi, Hojat Allah
    [J]. ADVANCES IN SCIENCE AND TECHNOLOGY-RESEARCH JOURNAL, 2016, 10 (30): : 96 - 102
  • [4] Optimal option selection for finishing works of high-rise building
    Hyun-Soo Lee
    San Roh
    Moon-Seo Park
    Han-Guk Ryu
    [J]. KSCE Journal of Civil Engineering, 2010, 14 : 639 - 651
  • [5] Optimal Design of SRC Transfer Beam of High-rise Building
    Liang, Bin
    Zhang, Zhaoliang
    Li, Rong
    [J]. CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 1884 - 1887
  • [6] Optimal option selection for finishing works of high-rise building
    Lee, Hyun-Soo
    Roh, San
    Park, Moon-Seo
    Ryu, Han-Guk
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2010, 14 (05) : 639 - 651
  • [7] Towards optimal design of high-rise building tube systems
    Shin, Myoungsu
    Kang, Thomas H. -K.
    Pimentel, Benjamin
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2012, 21 (06): : 447 - 464
  • [8] Optimal sensor placement for high-rise building via genetic algorithms and improved information matrix criterion
    Zhan, Shulin
    Huang, Fang
    Lai, Junying
    [J]. ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 1653 - 1659
  • [9] HIGH-RISE BUILDING AND METROPOLITAN LANDSCAPE
    Montenegro-Miranda, German
    [J]. BITACORA URBANO TERRITORIAL, 2018, 28 (02): : 73 - 82
  • [10] Building high-rise modular homes
    Capita Symonds, United Kingdom
    [J]. Struct Eng, 2007, 1 (20-21):