A COMPARISON OF SOFT-TISSUE IMPLANTED MARKERS AND BONY ANATOMY ALIGNMENTS FOR IMAGE-GUIDED TREATMENTS OF HEAD-AND-NECK CANCERS

被引:9
|
作者
Zeidan, Omar A. [1 ]
Huddleston, Adam J. [1 ]
Lee, Choonik [1 ]
Langen, Katja M. [1 ]
Kupelian, Patrick A. [1 ]
Meeks, Sanford L. [1 ]
Manon, Rafael R. [1 ]
机构
[1] MD Anderson Canc Ctr Orlando, Dept Radiat Oncol, Orlando, FL 32806 USA
关键词
Daily IGRT; Head-and-neck cancer; Megavoltage CT; Bony anatomy Alignment; Implanted markers; MEGAVOLTAGE COMPUTED-TOMOGRAPHY; MODULATED RADIATION-THERAPY; DEFORMABLE REGISTRATION; GEOMETRIC CHANGES; RADIOTHERAPY; EXPERIENCE; FIDUCIALS; GUIDANCE; GLAND; MVCT;
D O I
10.1016/j.ijrobp.2009.02.060
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. Methods and Materials: A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. Results: Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within +/- 5%) compared with the kilovoltage CT plan. Conclusion: The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques. (C) 2010 Elsevier Inc.
引用
收藏
页码:767 / 774
页数:8
相关论文
共 50 条
  • [1] Image-guided radiotherapy in head-and-neck oncology
    Balermpas, Panagiotis
    ONKOLOGIE, 2023, 29 (01): : 45 - 50
  • [2] Image-guided radiosurgery of head and neck cancers
    Ryu, S
    Khan, M
    Yin, FF
    Concus, A
    Ajlouni, M
    Benninger, MS
    Kim, JH
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 130 (06) : 690 - 697
  • [3] Using Image-guided Intensity-modulated Radiotherapy on Patients With Head and Neck Soft-tissue Sarcoma
    Elsayad, Khaled
    Stockmann, Denise
    Channaoui, Mohammed
    Scobioala, Sergiu
    Grajda, Aneta
    Berssenbruegge, Hendrik
    Huss, Sebastian
    Moustakis, Christos
    Haverkamp, Uwe
    Kleinheinz, Johannes
    Lenz, Georg
    Wardelmann, Eva
    Eich, Hans Theodor
    IN VIVO, 2019, 33 (04): : 1293 - 1300
  • [4] Dose reconstruction for image-guided head and neck cancers
    Chase, D
    Ramsey, C
    Scaperoth, D
    Mahan, S
    Seibert, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S557 - S558
  • [5] A dosimetric evaluation of markers vs. bony anatomy alignments for a head and neck case
    Zeidan, O. A.
    Lee, C.
    Langen, K.
    Kupelian, P.
    Manon, R.
    Meeks, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S460 - S460
  • [6] Soft tissue navigation and image-guided removal of foreign bodies in head and neck surgery
    Bumm, K.
    Bohr, C.
    Bozzato, A.
    Wurm, J.
    HNO, 2009, 57 (10) : 1016 - 1022
  • [7] Soft-Tissue Modeling and Image-Guided Control of Steerable Needles
    Sadati, Nasser
    Torabi, Meysam
    Vaziri, Reza
    Dehestani-Ardekani, Reza
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5122 - +
  • [8] Evaluation of daily tumor localization shifts in the H&N region based on bony anatomy and soft-tissue implanted markers
    Zeidan, O.
    Kupelian, P.
    Langen, K.
    Marion, R.
    Meeks, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2381 - 2381
  • [9] Image-guided soft-tissue foreign body extraction - Success and pitfalls
    Bradley, Mike
    CLINICAL RADIOLOGY, 2012, 67 (06) : 531 - 534
  • [10] Implanted gold markers for position verification during irradiation of head-and-neck cancers: A feasibility study
    van Asselen, BA
    Dehnad, H
    Raaijmakers, CPJ
    Lagendijk, JJW
    Terhaard, CHJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1011 - 1017