Laboratory XRF Measurements Using Alpha Particle X-ray Spectrometer of Chandrayaan-2 Rover: Comparison with Geant4 Simulation Results

被引:0
|
作者
Goyal, S. K. [1 ]
Shanmugam, M. [1 ]
Vadawale, S. [1 ]
Banerjee, D. [1 ]
Acharya, Y. B. [1 ]
Murty, S. V. S. [1 ]
机构
[1] Phys Res Lab, Ahmadabad 380009, Gujarat, India
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
India's second mission to the Moon - Chandrayaan - 2, will have a rover for in-situ exploration of lunar surface around the landing site. Alpha Particle X-ray Spectrometer (APXS) is one of the instruments on board Chandrayaan-2 rover, for measuring elemental composition of the lunar surface using state - of - the - art X-ray detector (Silicon Drift Detector - SDD) with higher energy resolution. The objective of the APXS instrument is to analyze several soil/rock samples along the rover traverse for the major elements with the characteristics Xrays in the 1 to 25 keV energy range. We have carried out XRF measurements in the laboratory using Alpha Particle X-ray Spectrometer which provides energy resolution of similar to 150 eV at 5.9 keV, when the detector is cooled to -35 degrees C. These measurements are carried out using six Fe-55 X-ray sources for various target materials at different detector to target heights. We have also carried out detailed Monte-Carlo simulation based on GEANT4 for the APXS for various compositions of the lunar surface. Here we are comparing the GEANT4 simulation results with the experimentally acquired XRF data.
引用
收藏
页数:6
相关论文
共 18 条
  • [1] Alpha Particle X-ray Spectrometer onboard Chandrayaan-2 Rover
    Shanmugam, M.
    Vadawale, S. V.
    Patel, Arpit R.
    Mithun, N. P. S.
    Adalaja, Hitesh Kumar
    Ladiya, Tinkal
    Goyal, Shiv Kumar
    Tiwari, Neeraj K.
    Singh, Nishant
    Kumar, Sushil
    Painkra, Deepak Kumar
    Hait, A. K.
    Patinge, A.
    Kumar, Abhishek
    Basha, Saleem
    Subramanian, Vivek R.
    Venkatesh, R. G.
    Prashant, D. B.
    Navle, Sonal
    Acharya, Y. B.
    Murty, S. V. S.
    Bhardwaj, Anil
    CURRENT SCIENCE, 2020, 118 (01): : 53 - 61
  • [2] Alpha Particle X-Ray Spectrometer (APXS) on-board Chandrayaan-2 rover
    Shanmugam, M.
    Murty, S. V. S.
    Acharya, Y. B.
    Goyal, S. K.
    Patel, Arpit R.
    Shah, Bhumi
    Hait, A. K.
    Patinge, Aditya
    Subrahrnanyam, D.
    ADVANCES IN SPACE RESEARCH, 2014, 54 (10) : 1974 - 1984
  • [3] Ground calibration of Alpha Particle X-ray Spectrometer (APXS) on-board Chandrayaan-2 Pragyaan rover: An empirical approach
    Mithun, N. P. S.
    Vadawale, Santosh V.
    Shanmugam, M.
    Patel, Arpit R.
    Singh, Nishant
    Kumar, Sushil
    Tiwari, Neeraj Kumar
    Goyal, Shiv Kumar
    Sarbadhikari, Amit Basu
    Arora, Garima
    Srivastava, Yash
    Adalja, Hitesh Kumar
    Ladiya, Tinkal
    Painkra, Deepak Kumar
    Banerjee, Swaroop B.
    Patel, Vishnubhai R.
    Bhardwaj, Anil
    PLANETARY AND SPACE SCIENCE, 2020, 187 (187)
  • [4] Geant4 simulations of soft proton scattering in X-ray opticsA tentative validation using laboratory measurements
    Valentina Fioretti
    Teresa Mineo
    Andrea Bulgarelli
    Paolo Dondero
    Vladimir Ivanchenko
    Fan Lei
    Simone Lotti
    Claudio Macculi
    Alfonso Mantero
    Experimental Astronomy, 2017, 44 : 413 - 435
  • [5] Chandrayaan-2 Large Area Soft X-ray Spectrometer (CLASS): Calibration, In-flight performance and first results
    Pillai, Netra S.
    Narendranath, S.
    Vadodariya, K.
    Tadepalli, Srikar P.
    Radhakrishna, V
    Tyagi, Anurag
    Yadav, Reena
    Singh, Brajpal
    Sharan, Vaishali
    Athiray, P. S.
    Sreekumar, P.
    Sankarasubramanian, K.
    Bhatt, Megha
    Sarbadhikari, Amit Basu
    Mithun, N. P. S.
    Vadawale, Santosh
    ICARUS, 2021, 363
  • [6] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Mehdi, Abbasian Motlagh
    Gohar, Rastegarzadeh
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2023, 66 (03) : 451 - 455
  • [7] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Abbasian Motlagh Mehdi
    Rastegarzadeh Gohar
    Instruments and Experimental Techniques, 2023, 66 : 451 - 455
  • [8] Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4
    Nasseri, Mohammad M.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (03) : 795 - 798
  • [9] SOLPEX X-ray polarimeter detector luminescence background calculated using Geant4 simulation software
    Gorgolewski, Aleksander
    Barylak, Jaromir
    Steslicki, Marek
    Szaforz, Zaneta
    Bakala, Jaroslaw
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2016, 2016, 10031
  • [10] GAMOS/GEANT4 simulation and comparison study of X-ray narrow-spectrum series at the national Secondary Standard Dosimetry Laboratory of Morocco
    Al-Tuweity, Jawaher
    Sadiq, Younes
    Mouktafi, Amine
    Arce, Pedro
    Fathi, Imane
    Mohammed, Maged
    Azougagh, Mohamed
    Alibrahmi, El Mehdi
    Boukhal, Hamid
    Chakir, El Mahjoub
    APPLIED RADIATION AND ISOTOPES, 2021, 175