Assessment of Virtual Monoenergetic Images in Run-off Computed Tomography Angiography: A Comparison Study to Conventional Images From Spectral Detector Computed Tomography

被引:6
|
作者
Ren, Haiyan [1 ]
Zhen, Yanhua [1 ]
Gong, Zheng [1 ]
Wang, Chuanzhuo [1 ]
Chang, Zhihui [1 ]
Zheng, Jiahe [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang, Peoples R China
关键词
spectral detector CT; virtual monoenergetic images; angiography;
D O I
10.1097/RCT.0000000000001126
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aims of this study were to evaluate image quality of virtual monoenergetic images (VMIs) compared with conventional images (CIs) from spectral detector CT (SDCT) and to explore the optimal energy level in run-off computed tomography angiography (CTA). Methods The data sets of 35 patients who received run-off CTA on the SDCT were collected in this retrospective study. Conventional images were generated via iterative reconstruction algorithm and VMI series from 40 to 120 keV were generated via spectral reconstruction algorithm. The objective indices including vascular attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio were compared. Two readers performed subjective evaluation using a 5-point scale. Results The attenuation showed higher values compared with CIs at 40 to 60 keV (P < 0.001). The noise was similar in 60- to 80-keV VMIs and significantly decreased in 90- to 120-keV VMIs (P < 0.001) in comparison with CIs. The signal-to-noise ratio and contrast-to-noise ratio were improved in 40- to 60-keV VMIs compared with CIs (P < 0.05). The score of subjective assessment was higher than that of CIs in 50- to 70-keV VMIs (P < 0.001). Conclusions Virtual monoenergetic images can provide improved image quality compared with CIs from SDCT in run-off CTA, and VMIs at 60 keV may be the best choice in evaluating lower extremity arteries.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 50 条
  • [1] Effect of Virtual Monoenergetic Images From Spectral Detector Computed Tomography on Coronary Calcium Blooming
    Van Hedent, Steven
    Hokamp, Nils Grosse
    Kessner, Rivka
    Gilkeson, Robert
    Ros, Pablo R.
    Gupta, Amit
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 912 - 918
  • [2] Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions
    Reimer, R. P.
    Grosse Hokamp, N.
    Fehrmann Efferoth, A.
    Krauskopf, A.
    Zopfs, D.
    Kroeger, J. R.
    Persigehl, T.
    Maintz, D.
    Bunck, A. C.
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 3468 - 3477
  • [3] Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions
    R. P. Reimer
    N. Große Hokamp
    A. Fehrmann Efferoth
    A. Krauskopf
    D. Zopfs
    J. R. Kröger
    T. Persigehl
    D. Maintz
    A. C. Bunck
    European Radiology, 2021, 31 : 3468 - 3477
  • [4] Quantification of airway wall contrast enhancement on virtual monoenergetic images from spectral computed tomography
    Bodenberger, Arndt Lukas
    Konietzke, Philip
    Weinheimer, Oliver
    Wagner, Willi Linus
    Stiller, Wolfram
    Weber, Tim Frederik
    Heussel, Claus Peter
    Kauczor, Hans-Ulrich
    Wielpuetz, Mark Oliver
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5557 - 5567
  • [5] Quantification of airway wall contrast enhancement on virtual monoenergetic images from spectral computed tomography
    Arndt Lukas Bodenberger
    Philip Konietzke
    Oliver Weinheimer
    Willi Linus Wagner
    Wolfram Stiller
    Tim Frederik Weber
    Claus Peter Heussel
    Hans-Ulrich Kauczor
    Mark Oliver Wielpütz
    European Radiology, 2023, 33 : 5557 - 5567
  • [6] Phantom Validation of Spectral Detector Computed Tomography-Derived Virtual Monoenergetic, Virtual Noncontrast, and Iodine Quantification Images
    Ananthakrishnan, Lakshmi
    Duan, Xinhui
    Rajiah, Prabhakar
    Soesbe, Todd C.
    Lewis, Matthew A.
    Xi, Yin
    Fielding, Julia R.
    Lenkinski, Robert E.
    Leyendecker, John R.
    Abbara, Suhny
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 959 - 964
  • [7] Metal Artifact Reduction in Routine Chest and Abdominal Examinations Using Virtual Monoenergetic Images From Spectral Detector Computed Tomography
    Van Hedent, Steven
    Kessner, Rivka
    Grosse Hokamp, Nils
    Baran, Tomer Ziv
    Kosmas, Christos
    Gupta, Amit
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (05) : 713 - 717
  • [8] Virtual monoenergetic images from photon-counting spectral computed tomography to assess knee osteoarthritis
    Chappard, Christine
    Abascal, Juan
    Olivier, Cecile
    Si-Mohamed, Salim
    Boussel, Loic
    Piala, Jean Baptiste
    Douek, Philippe
    Peyrin, Francoise
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [9] Virtual monoenergetic images from photon-counting spectral computed tomography to assess knee osteoarthritis
    Christine Chappard
    Juan Abascal
    Cécile Olivier
    Salim Si-Mohamed
    Loic Boussel
    Jean Baptiste Piala
    Philippe Douek
    Francoise Peyrin
    European Radiology Experimental, 6
  • [10] Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography
    Ghandour, Abed
    Sher, Andrew
    Rassouli, Negin
    Dhanantwari, Amar
    Rajiah, Prabhakar
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 858 - 865