Water transport during startup and shutdown of polymer electrolyte fuel cell stacks

被引:12
|
作者
Wang, X. [1 ]
Tajiri, K. [1 ]
Ahluwalia, R. K. [1 ]
机构
[1] Argonne Natl Lab, Nucl Engn Div, Argonne, IL 60439 USA
关键词
Polymer electrolyte fuel cells; Cold-start; Shutdown; CATALYST LAYER; ICE FORMATION; PEFC; -20-DEGREES-C; TEMPERATURE; OPERATION; REMOVAL; DESIGN;
D O I
10.1016/j.jpowsour.2010.04.012
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A dynamic three-phase transport model is developed to analyze water uptake and transport in the membrane and catalyst layers of polymer electrolyte fuel cells during startup from subfreezing temperatures and subsequent shutdown. The initial membrane water content (lambda, the number of water molecules per sulfonic acid site) is found to be an important parameter that determines whether a successful unassisted self-start is possible. For a given initial subfreezing temperature at startup, there is a critical lambda (lambda(h)), above which self-start is not possible because the product water completely engulfs the catalyst layers with ice before the stack can warm-up to 0 degrees C. There is a second value of lambda (lambda(1)), below which the stack can be self-started without forming ice. Between lambda(1) and lambda(h), the stack can be self-started, but with intermediate formation of ice that melts as the stack warms up to 0 degrees C. Both lambda(1) and lambda(h), are functions of the initial stack temperature, cell voltage at startup, membrane thickness, catalyst loading, and stack heat capacity. If the stack is purged during the previous shutdown by flowing air in the cathode passages, then depending on the initial amount of water in the membrane and gas diffusion layers and the initial stack temperature, it may not be possible to dry the membrane to the critical lambda for a subsequent successful startup. There is an optimum lambda for robust and rapid startup and shutdown. Startup and shutdown time and energy may be unacceptable if the lambda is much less than the optimum. Conversely, a robust startup from subfreezing temperatures cannot be assured if the lambda is much higher than this optimum. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:6680 / 6687
页数:8
相关论文
共 50 条
  • [1] Numerical Model of Polymer Electrolyte Membrane Fuel Cell Startup and Shutdown
    Maranzana, G.
    Lamibrac, A.
    Dillet, J.
    Abbou, S.
    Didierjean, S.
    Lottin, O.
    [J]. POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 1619 - 1630
  • [2] Spatially resolved degradation during startup and shutdown in polymer electrolyte membrane fuel cell operation
    Babu, S. Komini
    Spernjak, D.
    Dillet, J.
    Lamibrac, A.
    Maranzana, G.
    Didierjean, S.
    Lottin, O.
    Borup, R. L.
    Mukundan, R.
    [J]. APPLIED ENERGY, 2019, 254
  • [3] Startup (and Shutdown) Model for Polymer Electrolyte Membrane Fuel Cells
    Maranzana, G.
    Lamibrac, A.
    Dillet, J.
    Abbou, S.
    Didierjean, S.
    Lottin, O.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (07) : F694 - F706
  • [4] EFFECT OF TEMPERATURE GRADIENT ON END CELL WATER TRANSPORT IN A POLYMER ELECTROLYTE FUEL CELL AFTER SHUTDOWN
    Khandelwal, Manish
    Mench, Matthew M.
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY, 2009, : 339 - 346
  • [5] Visualization Measurement of Water Freezing in the Cathode of a Polymer Electrolyte Fuel Cell during Cold Startup
    Nishida, Kosuke
    Ito, Hirokazu
    Tsushima, Shohji
    Hirai, Shuichiro
    [J]. KAGAKU KOGAKU RONBUNSHU, 2011, 37 (01) : 57 - 63
  • [6] An integrated modeling approach for temperature driven water transport in a polymer electrolyte fuel cell stack after shutdown
    Khandelwal, Manish
    Mench, M. M.
    [J]. JOURNAL OF POWER SOURCES, 2010, 195 (19) : 6549 - 6558
  • [7] Lifetime prediction of a polymer electrolyte membrane fuel cell via an accelerated startup-shutdown cycle test
    Bae, Suk Joo
    Kim, Seong-Joon
    Park, Jong In
    Park, Chan Woong
    Lee, Jin-Hwa
    Song, Inseob
    Lee, Naesung
    Kim, Ki-Bum
    Park, Jun-Young
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (12) : 9775 - 9781
  • [8] Development of small polymer electrolyte fuel cell stacks
    Paganin, VA
    Ticianelli, EA
    Gonzalez, ER
    [J]. JOURNAL OF POWER SOURCES, 1998, 70 (01) : 55 - 58
  • [9] Cell interaction phenomena in polymer electrolyte fuel cell stacks
    Freunberger, Stefan A.
    Schneider, Ingo A.
    Sui, Pang-Chieh
    Wokaun, Alexander
    Djilali, Nedjib
    Buchi, Felix N.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2008, 155 (07) : B704 - B714
  • [10] Water transport characteristics of polymer electrolyte membrane fuel cell
    Rajalakshmi, N
    Jayanth, TT
    Thangamuthu, R
    Sasikumar, G
    Sridhar, P
    Dhathathreyan, KS
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2004, 29 (10) : 1009 - 1014