Whole body and distal organ-specific dosimetry using parallel SN methods

被引:0
|
作者
Al-Basheer, A. [1 ]
Ghita, M. [1 ]
Sjoden, G. [1 ]
Bolch, W. [1 ]
Lee, C. [1 ]
机构
[1] Univ Florida, Gainesville, FL USA
关键词
D O I
10.1118/1.2760427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To create a new methodology for dose computations applicable to general medical physics applications, based upon a direct deterministic solution of the (3‐D) Boltzmann transport equation (BTE). Method and Materials: Using the multigroup discrete ordinates (SN) deterministic method in the PENTRAN‐MP (Parallel Environment Neutral‐particle TRANsport‐Medical Physics) code system, fluxes and corresponding doses were determined for a clinical test case using a UF Series B whole‐body voxelized pediatric patient phantom. With a 90 keV planar x‐ray source, we performed two sets of transport calculations based on the same phantom model, employing both the Monte Carlo (MC) and SN methods. SN calculations were performed using PENTRAN, and the MCNP5 code was used for MC calculations. Post processing in the PENTRAN‐MP code system includes seamless parallel data extraction using the PENDATA code, followed by application of the 3D‐DOSE code to compute dose in each phantom voxel, with dose‐volume histograms for critical organs of interest. Results: We demonstrate that the deterministic SN and MC solutions are, in the vicinity of the source region, completely in agreement; the largest statistical error of the MC simulation was <5%, typically averaging <2%. Moreover, the deterministic SN method also provided globally converged results in each voxel at sites distal to the source (in ∼3 hrs on 16 processors), where the MC results on the same computing platform had significant out of field error, and would require a significantly longer running time (estimated at >2000 hrs) to produce meaningful results with an acceptable stochastic error to enable comparison with the well‐converged SN results. Conclusions: A new methodology for 3D dose calculations has been developed based on a parallel discrete ordinates (SN) solution of the BTE. With the proper discretization applied, the SN method presents an accurate, fast solution yielding a complete 3‐D dose distribution without stochastic error. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2349 / 2349
页数:1
相关论文
共 50 条
  • [1] Should we be using organ-specific antigens to understand organ-specific autoimmune disease?
    Fox, Robert I.
    [J]. CLINICAL IMMUNOLOGY, 2013, 146 (02) : 153 - 154
  • [3] Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body
    Tward, Daniel J.
    Ceritoglu, Can
    Kolasny, Anthony
    Sturgeon, Gregory M.
    Segars, W. Paul
    Miller, Michael I.
    Ratnanather, J. Tilak
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2011, 2011
  • [4] Organ specific bremsstrahlung imging using whole body phantom
    Shukla, A. K.
    Kheruka, S. C.
    Kumar, U.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S341 - S341
  • [5] Unique Metabolic Adaptations Dictate Distal Organ-Specific Metastatic Colonization
    Schild, Tanya
    Low, Vivien
    Blenis, John
    Gomes, Ana P.
    [J]. CANCER CELL, 2018, 33 (03) : 347 - 354
  • [6] A review of methods available for the identification of both organ-specific and non-organ-specific autoantibodies
    Miles, J
    Charles, P
    Riches, P
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 19 - 47
  • [7] STANDARDIZATION OF ORGAN SPECIFIC BREMSSTRAHLUNG IMAGING USING WHOLE BODY PHANTOM
    Shukla, A. K.
    Kheruka, S. C.
    Lassmann, M.
    Werener, E.
    Whal, W.
    Kucheida, D.
    Das, B. K.
    Gambhir, S.
    Pradhan, P. K.
    Kumar, Utham
    [J]. JOURNAL OF MEDICAL PHYSICS, 2005, 30 (01) : 1 - 13
  • [8] ANTIBODIES ORGAN-SPECIFIC AGAINST THE ANTERIOR BODY OF THE PITUITARY GLAND
    Kestner, Otto
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1938, 92 (03): : 273 - 275
  • [9] Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry
    Andrew P. Robinson
    Jill Tipping
    David M. Cullen
    David Hamilton
    Richard Brown
    Alex Flynn
    Christopher Oldfield
    Emma Page
    Emlyn Price
    Andrew Smith
    Richard Snee
    [J]. EJNMMI Physics, 3
  • [10] Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry
    Robinson, Andrew P.
    Tipping, Jill
    Cullen, David M.
    Hamilton, David
    Brown, Richard
    Flynn, Alex
    Oldfield, Christopher
    Page, Emma
    Price, Emlyn
    Smith, Andrew
    Snee, Richard
    [J]. EJNMMI PHYSICS, 2016, 3 (01): : 1 - 11