Accuracy of an unattended home CPAP titration in the treatment of obstructive sleep apnea

被引:57
|
作者
Sériès, F
机构
[1] Hop Laval, Ctr Pneumol, Unite Rech, Ste Foy, PQ G1V 4G5, Canada
[2] Univ Laval, Quebec City, PQ, Canada
关键词
D O I
10.1164/ajrccm.162.1.9908023
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Treatment of sleep apnea-hypopnea syndrome (SAHS) by fixed continuous positive airway pressure (CPAP) requires an in-laboratory titration procedure to determine the effective pressure level (Peff), We recently reported that one auto-CPAP machine can be used without titration study allowing Peff determination. The aim of this study was to evaluate the accuracy of an auto CPAP trial at home. A 1- or 2-wk automatic CPAP trial was done at home in 40 patients by estimating the reference pressure (Pref) to be set and a Pref + 3 cm H2O/-4 cm H2O pressure interval. Peff was then determined according to the percentage of CPAP time that was spent less than or equal to Pref. This Peff value was set on a fixed CPAP machine for two additional weeks and a control sleep study was done. The pressure setting on fixed CPAP had to be increased by 1 +/- 1 cm H2O (mean +/- SD) above estimated Pref. Sleep improved with fixed CPAP, with a normalization of the apnea + hypopnea index (AHI) in 38 of 40 and resumption of diurnal hypersomnolence. CPAP compliance remained excellent (CPAP use: 6.1 +/- 1.7 h/night) after 6.5 +/- 2.8 mo of CPAP treatment. These results indicate that auto-CPAP therapy represents a new useful and accurate way to identify conventional CPAP setting outside hospital and sleep laboratories.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 50 条
  • [1] Home Unattended Portable Monitoring and Automatic CPAP Titration in Patients with High Risk for Moderate to Severe Obstructive Sleep Apnea
    Tedeschi, Ersilia
    Carratu, Pierluigi
    Damiani, Mario Francesco
    Ventura, Valentina Anna
    Drigo, Riccardo
    Enzo, Edda
    Ferraresso, Alberto
    Sasso, Geo
    Zambotto, Franco Maria
    Resta, Onofrio
    RESPIRATORY CARE, 2013, 58 (07) : 1178 - 1183
  • [2] Unattended home diagnosis and treatment of obstructive sleep apnea without polysomnography
    Fletcher, EC
    Stich, J
    Yang, KL
    ARCHIVES OF FAMILY MEDICINE, 2000, 9 (02) : 168 - 174
  • [3] RESTFUL SLEEP AFTER CPAP TITRATION FOR OBSTRUCTIVE SLEEP APNEA (OSA)
    Nassif, G. M.
    Dabbagh, O.
    Sivaraman, M.
    Sahota, P.
    SLEEP, 2009, 32 : A238 - A238
  • [4] Cpap Acceptance And Adherence In Patients With Obstructive Sleep Apnea - Effect Of Cpap Titration
    Yoshimura, C.
    Yanai, A.
    Murakami, E.
    Yoshimoto, M.
    Moriyama, N.
    Nishizaka, M.
    Ando, S. -I.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [5] Optimizing CPAP Treatment for Obstructive Sleep Apnea
    Hiensch R.
    Nandedkar D.S.
    Feinsilver S.H.
    Current Sleep Medicine Reports, 2016, 2 (2) : 120 - 125
  • [6] Comparison of CPAP titration at home or the sleep laboratory in the sleep apnea hypopnea syndrome
    Cross, Melanie D.
    Vennelle, Marjorie
    Engleman, Heather M.
    White, Sandra
    Mackay, Thomas W.
    Twaddle, Sarah
    Douglas, Neil J.
    SLEEP, 2006, 29 (11) : 1451 - 1455
  • [7] Accuracy of autotitrating CPAP to estimate the residual Apnea–Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP
    Himanshu Desai
    Anil Patel
    Pinal Patel
    Brydon J. B. Grant
    M. Jeffery Mador
    Sleep and Breathing, 2009, 13 : 383 - 390
  • [8] Efficacy of daytime CPAP titration in severe obstructive sleep apnea (OSA).
    Rudkowski, J
    Verschelden, P
    Bernad, D
    Kimoff, RJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A426 - A426
  • [9] Comparison of sleep arousals before and after CPAP titration in patients with obstructive sleep apnea
    Adlakha, A.
    Gross, P. T.
    SLEEP, 2006, 29 : A157 - A157
  • [10] CPAP in Obstructive Sleep Apnea
    Chervin, Ronald D.
    Rosen, Ilene M.
    Watson, Nathaniel F.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (23): : 2301 - 2302