Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay

被引:119
|
作者
van den Ouweland, Johannes M. W. [1 ]
Beijers, Antonius M. [1 ]
Demacker, Pierre N. M. [1 ]
van Daal, Henny [1 ]
机构
[1] Canisius Wilhelmina Hosp, Dept Clin Chem, NL-6532 SZ Nijmegen, Netherlands
关键词
25-Hydroxyvitamin D; LC-MS/MS; Radioimmunoassay; Method comparison; VITAMIN-D DEFICIENCY; 25-HYDROXYVITAMIN D-3; QUANTIFICATION; ACCURACY;
D O I
10.1016/j.jchromb.2010.03.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The plasma 25-OH vitamin D concentration is a reliable biomarker for vitamin D status but assay's variability makes adequate monitoring of vitamin D status difficult. We employed isotope-dilution liquid chromatography (LC) tandem-mass spectrometry (MS/MS) for the measurement of both 25-OH vitamin D(3) and 25-OH vitamin D(2) in human serum. Hexadeuterium labelled 25-OH vitamin D(3) internal standard (IS) was added to calibrators (prepared in phosphate-buffered saline with 60 g/L albumin), controls or patient sera and 25-OH vitamin D metabolites were released from vitamin D binding protein by adding sodium hydroxide prior to protein precipitation by acetonitrile/methanol (9:1, v/v). Subsequent off-line solid-phase extraction was followed by chromatographic separation on a C-18 column using a water/methanol/ammonium acetate gradient. Detection was by Atmospheric Pressure Electrospray Ionisation (AP-EI) followed by selected reaction monitoring. We compared the LC-MS/MS assay to the DiaSorin radioimmunoassay (RIA) and a recently re-standardised version of an automated electrochemi-luminescent immunoassay (ECLIA) from Roche Diagnostics. We also analysed external quality control samples from the International Vitamin D External Quality Assessment Scheme (DEQAS) for comparison with other participating laboratories using LC-MS. The method was linear from 5 to at least 550 nmol/L with intra- and interday CV's <= 6% for both 25-OH vitamin D(3) and 25-OH vitamin D(2). Recoveries ranged between 94.9 and 106.9% for 25-OH vitamin D(3) and 82.7 and 100.3% for 25-OH vitamin D(2). Our results for the DEQAS serum pools averaged 7.2% from the overall LC-MS method mean. The DiaSorin RIA agreed well with the LC-MS/MS method (r(2) = 0.90; average bias 1.61 nmol/L), the Roche ECLIA considerably disagreed (r2 = 0.58: bias 10.13 nmol/L). This LC-MS/MS method is reliable and robust for the measurement of both 25-OH vitamin D(3) and 25-OH vitamin D(2) in human serum. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1163 / 1168
页数:6
相关论文
共 50 条
  • [1] Measurement of Serum Total Vitamin D (25-OH) Using Automated Immunoassay in Comparision With Liquid Chromatography Tandem-Mass Spectrometry
    Shin, Sang-Yong
    Kwon, Min-Jung
    Song, Junghan
    Park, Hyosoon
    Woo, Hee-Yeon
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2013, 27 (04) : 284 - 289
  • [2] Measurement of 25-hydroxyvitamin vitamin D by liquid chromatography tandem-mass spectrometry with comparison to automated immunoassays
    Carrozza, Cinzia
    Persichilli, Silvia
    Canu, Giulia
    Gervasoni, Jacopo
    Torti, Eleonora
    Tazza, Luigi
    Zuppi, Cecilia
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (11) : 2033 - 2035
  • [3] Measurement of Serum Total Vitamin D (25-OH) Using Automated Immunoassay in Comparision with Liquid Chromatography Tandem-Mass Spectrometry (vol 27, pg 284, 2013)
    Shin, Sang-Yong
    Kwon, Min-Jung
    Song, Junghan
    Park, Hyosoon
    Woo, Hee-Yeon
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2013, 27 (05) : 340 - 340
  • [4] Comparison between liquid chromatography-tandem mass spectrometry and immunoassay methods for measurement of plasma 25 (OH) vitamin D
    Kader, Saadet
    Akdag, Turan
    Ecer, Busra
    Abusoglu, Sedat
    Unlu, Ali
    [J]. TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2022, 47 (06): : 710 - 718
  • [5] Four Automated 25-OH Total Vitamin D Immunoassays and Commercial Liquid Chromatography Tandem-Mass Spectrometry in Finnish Population
    Koivula, Marja-Kaisa
    Matinlassi, Nina
    Laitinen, Paivi
    Risteli, Juha
    [J]. CLINICAL LABORATORY, 2013, 59 (3-4) : 397 - 405
  • [6] Comparison of Automated Immunoassay and Liquid Chromatography Tandem Mass Spectrometry for 25-Hydroxyvitamin D
    Parajuli, S.
    Bhattacharyya, S.
    Hotchandani, N.
    Khan, A.
    Goldsmith, B. M.
    [J]. LABORATORY INVESTIGATION, 2014, 94 : 527A - 527A
  • [7] Comparison of Automated Immunoassay and Liquid Chromatography Tandem Mass Spectrometry for 25-Hydroxyvitamin D
    Parajuli, S.
    Bhattacharyya, S.
    Hotchandani, N.
    Khan, A.
    Goldsmith, B. M.
    [J]. MODERN PATHOLOGY, 2014, 27 : 527A - 527A
  • [8] Comparison of Automated 25-OH Vitamin D Immunoassays with Liquid Chromatography Isotope Dilution Tandem Mass Spectrometry
    Koivula, Marja-Kaisa
    Turpeinen, Ursula
    Laitinen, Paivi
    Risteli, Juha
    [J]. CLINICAL LABORATORY, 2012, 58 (11-12) : 1253 - 1261
  • [9] Comparison of the Analytical and Diagnostic Performance of an Automated Immunoassay and Liquid Chromatography Tandem Mass Spectrometry for 25-hydroxy Vitamin D
    Malik, Aatika
    Chakraborty, Baidarbhi
    Patel, Viren
    Khan, Adil
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2016, 146
  • [10] Detection of Vitamin D Metabolites in Breast Milk: Perspectives and challenges for measurement by Liquid Chromatography Tandem-Mass Spectrometry
    Tuddenham, Carlie
    Greaves, Ronda F.
    Rajapaksa, Anushi E.
    Wark, John D.
    Zakaria, Rosita
    [J]. CLINICAL BIOCHEMISTRY, 2021, 97 : 1 - 10