Machine learning for the early prediction of head-up tilt testing outcome

被引:4
|
作者
He, Zhengling [1 ,3 ]
Du, Lidong [1 ,2 ]
Du, Song [5 ]
Wu, Bin [5 ]
Fan, Zhiqi [6 ]
Xin, Binmu [6 ]
Chen, Xianxiang [1 ,2 ,3 ]
Fang, Zhen [1 ,2 ,3 ]
Liu, Jiexin [4 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, Beijing, Peoples R China
[2] Chinese Acad Med Sci, Res Units Personalized Management Chron Resp Dis, Beijing, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Capital Med Univ, Beijing Tiantan Hosp, Beijing, Peoples R China
[5] Astronaut Ctr China, Beijing, Peoples R China
[6] Space Sci & Technol Inst Shenzhen, Shenzhen, Peoples R China
关键词
Head-up Tilt Testing (HUTT); Syncope; Machine learning; Genetic algorithm; Hemodynamic monitoring; FEATURE-SELECTION; GENETIC ALGORITHM; ARTERIAL-PRESSURE; SYNCOPE; CLASSIFICATION; NITROGLYCERIN; VARIABILITY;
D O I
10.1016/j.bspc.2021.102904
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Head-up Tilt Testing (HUTT) is a widely used medical tool for the diagnosis of unexplained syncope. Current HUTT protocols, however, are time-consuming. This study aims to investigate the feasibility of using hemodynamic monitoring and machine learning techniques to achieve early prediction of HUTT outcome for syncope patients. Methods: A total of 209 subjects participated in this study from June 2016 to November 2019, and hemodynamic signals were collected via a Finometer device (Finapres Medical Systems BV, The Netherlands). We extracted features with a total dimension of 4,313 from the early 18 min (5 min of supine position and 13 min of tilting position). A genetic algorithm (GA) was introduced for feature selection, and an index called the selection ratio (SR) was proposed to further analyze the GA selection result. Four machine learning models were established for this classification task, and their performance results were compared. Results: The maximum tilting duration was shortened from 35 min to 13 min, and a best area under receiver operating characteristic curve of 0.94 via 5-fold cross-validation was obtained by the SVR model, with a sensitivity of 0.86 and a specificity of 0.82. The performance of all algorithms improved after feature selection by GA. Conclusion: The proposed approach is a promising method to shorten the diagnosis time compared to the existing diagnosis process. The GA introduced in this study is an effective feature selection tool to improve model performance. The proposed SR index effectively contributes to the usability and interpretability of the model.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Quantitative Complexity Theory Used in the Prediction of Head-Up Tilt Testing Outcome
    Krzesinski, Pawel
    Marczyk, Jacek
    Wolszczak, Bartosz
    Gielerak, Grzegorz
    CARDIOLOGY RESEARCH AND PRACTICE, 2021, 2021
  • [2] Head-up tilt testing in children
    Seifer, CM
    Kenny, RA
    EUROPEAN HEART JOURNAL, 2001, 22 (21) : 1968 - 1971
  • [3] Age and outcome of head-up tilt table testing in syncope patients
    Shafiee, A.
    Sadeghian, S.
    Noormand, R.
    Davoodi, G.
    Yaminisharif, A.
    EUROPEAN HEART JOURNAL, 2015, 36 : 982 - 982
  • [4] Effect of passive tilting duration on the outcome of head-up tilt testing
    Lelonek, Malgorzata
    Stanczyk, Adam
    Goch, Jan Henryk
    ACTA CARDIOLOGICA, 2007, 62 (06) : 547 - 552
  • [5] Characteristics of head-up tilt testing with additional adenosine compared with head-up tilt testing with isoproterenol and isosorbide dinitrate
    Watanabe, Norikazu
    Kawasaki, Shirou
    Oonishi, Yoshimi
    Onuma, Yoshimasa
    Munetsugu, Yumi
    Itou, Takayuki
    Onuki, Tatsuya
    Miyoshi, Fumito
    Minoura, Yoshino
    Adachi, Tarou
    Kawamura, Mitsuharu
    Asano, Taku
    Tanno, Kaoru
    Kobayashi, Youichi
    JOURNAL OF ARRHYTHMIA, 2014, 30 (06) : 473 - 477
  • [6] Results of Head-Up Tilt Table testing
    Rakhmanova, D
    Dzidowski, J
    Webb, CR
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (07) : A349 - A349
  • [7] HEAD-UP TILT TESTING - THE BALANCE OF EVIDENCE
    MORILLO, CA
    ELLENBOGEN, KA
    KLEIN, GJ
    BRITISH HEART JOURNAL, 1995, 73 (06): : 583 - 583
  • [8] HEAD-UP TILT TESTING - THE BALANCE OF EVIDENCE
    HARGREAVES, AD
    ELHAG, O
    BOON, NA
    BRITISH HEART JOURNAL, 1994, 72 (03): : 216 - 217
  • [9] Early heart rate variations during head-up tilt table testing as a predictor of outcome of the test
    Alvarez, JB
    Asensio, E
    Lozano, JE
    Alvarez, M
    Portos, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (01): : 26 - 31
  • [10] Application of Head-up Tilt Table Testing in Children
    Lai, Wei-Ting
    Chen, Ming-Ren
    Lin, Shan-Miao
    Hwang, Haw-Kwei
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2010, 109 (09) : 641 - 646