Development of a calibration chamber to evaluate the performance of low-cost particulate matter sensors

被引:56
|
作者
Sayahi, T. [1 ]
Kaufman, D. [2 ]
Becnel, T. [3 ]
Kaur, K. [1 ]
Butterfield, A. E. [1 ]
Collingwood, S. [4 ]
Zhang, Y. [5 ]
Gaillardon, P. -E. [3 ]
Kelly, K. E. [1 ]
机构
[1] Univ Utah, Dept Chem Engn, 3290 MEB,50 S Cent Campus Dr, Salt Lake City, UT USA
[2] Kaufco Consulting LLC, 409 East Corner Bridge Lane, Draper, UT USA
[3] Univ Utah, Dept Elect & Comp Engn, Lab Nanolntegrated Syst, 50 S Cent Campus Dr, Salt Lake City, UT USA
[4] Univ Utah, Dept Pediat, 295 Chipeta Way, Salt Lake City, UT USA
[5] Univ Utah, Dept Internal Med, Div Epidemiol, 295 Chipeta Way, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Air quality; Calibration chamber; Low-cost sensors; Particulate matter; Evaluation of calibration chamber; AIR-POLLUTION; LABORATORY EVALUATION; MODEL; MONITORS; EXPOSURE; NETWORK; IMPROVE; AMBIENT;
D O I
10.1016/j.envpol.2019.113131
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-cost particulate matter (PM) air quality sensors are becoming widely available and are being increasingly deployed in ambient and home/workplace environments due to their low cost, compactness, and ability to provide more highly resolved spatiotemporal PM concentrations. However, the PM data from these sensors are often of questionable quality, and the sensors need to be characterized individually for the environmental conditions under which they will be making measurements. In this study, we designed and assessed a cost-effective (4700) calibration chamber capable of continuously providing a uniform PM concentration simultaneously to multiple low-cost PM sensors and robust calibration relationships that are independent of sensor position. The chamber was designed and evaluated with a Computational Fluid Dynamics (CFD) model and a rigorous experimental protocol. We then used this new chamber to calibrate 242 Plantower PMS 3003 sensors from two production lots (Batches I and II) with two aerosol types: ammonium nitrate (for Batches I and II) and alumina oxide (for Batch I). Our CFD models and experiments demonstrated that the chamber is capable of providing uniform PM concentration to 8 PM sensors at once within 6% error and with excellent reliability (intraclass correlation coefficient > 0.771). The study identified two malfunctioning sensors and showed that the remaining sensors had high linear correlations with a DustTrak monitor that was calibrated for each aerosol type (R-2 > 0.978). Finally, the results revealed statistically significant differences between the responses of Batches I and II sensors to the same aerosol (P-value<0.001) and the Batch I sensors to the two different aerosol types (P-value<0.001). This chamber design and evaluation protocol can provide a useful tool for those interested in systematic laboratory characterization of low-cost PM sensors. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] CFD Simulations Of An Aerosol Chamber For Calibration Of Low-Cost Particulate Matter Sensors
    Drzymalla, Jan
    Lay, Yannic
    Sauermann, Marc
    Henne, Andreas
    [J]. INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,
  • [2] Performance Evaluation of Low-cost Particulate Matter Sensors
    Marinov, Marin B.
    Hensel, Stefan
    Ganev, Borislav
    Nikolov, Georgi
    [J]. 2017 XXVI INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS (ET), 2017,
  • [3] Calibration of low-cost particulate matter sensors for coal dust monitoring
    Amoah, Nana A.
    Xu, Guang
    Kumar, Ashish Ranjan
    Wang, Yang
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 859
  • [4] In chamber calibration and performance evaluation of air quality low-cost sensors
    Agrawal, Deepali
    Saini, Anil Kumar
    Rai, Aakash Chand
    Kala, Prateek
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2024, 15 (12)
  • [5] Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
    Jorstad, Per-Martin
    Wojcikowski, Marek
    Tuan-Vu Cao
    Lepioufle, Jean-Marie
    Wojtkiewicz, Krystian
    Phuong Hoai Ha
    [J]. INTELLIGENT INFORMATION AND DATABASE SYSTEMS, ACIIDS 2023, PT I, 2023, 13995 : 248 - 260
  • [6] Regression methods in the calibration of low-cost sensors for ambient particulate matter measurements
    Marek Badura
    Piotr Batog
    Anetta Drzeniecka-Osiadacz
    Piotr Modzel
    [J]. SN Applied Sciences, 2019, 1
  • [7] Calibration Methods for Low-Cost Particulate Matter Sensors Considering Seasonal Variability
    Kang, Jiwoo
    Choi, Kanghyeok
    [J]. SENSORS, 2024, 24 (10)
  • [8] Regression methods in the calibration of low-cost sensors for ambient particulate matter measurements
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    [J]. SN APPLIED SCIENCES, 2019, 1 (06)
  • [9] Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study
    Zusman, Marina
    Schumacher, Cooper S.
    Gassett, Amanda J.
    Spalt, Elizabeth W.
    Austin, Elena
    Larson, Timothy V.
    Carvlin, Graeme
    Seto, Edmund
    Kaufman, Joel D.
    Sheppard, Lianne
    [J]. ENVIRONMENT INTERNATIONAL, 2020, 134
  • [10] Performance calibration of low-cost and portable particular matter (PM) sensors
    Liu, Di
    Zhang, Qiang
    Jiang, Jingkun
    Chen, Da-Ren
    [J]. JOURNAL OF AEROSOL SCIENCE, 2017, 112 : 1 - 10