Ultrasound-guided cannulation of the femoral vein in electrophysiological procedures: a systematic review and meta-analysis

被引:57
|
作者
Sobolev, Maria [1 ,2 ]
Shiloh, Ariel L. [2 ,3 ]
Di Biase, Luigi [1 ,2 ]
Slovut, David P. [1 ,2 ,4 ]
机构
[1] Montefiore Med Ctr, Dept Med, Div Cardiol, 111 East 210th St, Bronx, NY 10467 USA
[2] Albert Einstein Coll Med, 111 East 210th St, Bronx, NY 10467 USA
[3] Montefiore Med Ctr, Dept Med, Div Crit Care Med, Bronx, NY 10467 USA
[4] Montefiore Med Ctr, Dept Cardiothorac & Vasc Surg, 111 E 210th St, Bronx, NY 10467 USA
来源
EUROPACE | 2017年 / 19卷 / 05期
关键词
Vascular; Ultrasound; Electrophysiology; Complications; ATRIAL-FIBRILLATION; CATHETER ABLATION; MANAGEMENT; COMPLICATIONS; DEFINITIONS; SAFETY;
D O I
10.1093/europace/euw113
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In an effort to minimize periprocedural stroke risk, increasingly, electrophysiological (EP) procedures are being performed on anticoagulation. The decrease in stroke has been accompanied by an increase in potentially devastating vascular access complications. Ultrasound guidance for femoral vein cannulation reduces complications in other applications. The aim of this study is to determine the utility of real-time two-dimensional (2D) ultrasound guidance for femoral vein cannulation in EP. Methods and results A comprehensive literature search of Medline, Embase, Google Scholar, and the Cochrane Central Register of Controlled Trials was performed. Five years of conference abstracts from the Heart Rhythm Society, European Heart Rhythm Association, and European Cardiac Arrhythmia Society were reviewed. Two independent reviewers identified trials comparing ultrasound-guided with standard cannulation in EP procedures. Data were extracted on study design, study size, operator and patient characteristics, use of anticoagulation, vascular complication rates, first-pass success rate, and inadvertent arterial puncture. Four trials, with a total of 4065 subjects, were included in the review, with 1848 subjects in the ultrasound group and 2217 subjects in the palpation group. Ultrasound guidance for femoral vein cannulation was associated with a 60% reduction of major vascular bleeding (relative risk, 0.40; 95% confidence interval, 0.28-0.91). Additionally, there was a 66% reduction in minor vascular complications (relative risk, 0.34; 95% confidence interval, 0.15-0.78). Conclusion The use of real-time 2D ultrasound guidance for femoral vein cannulation decreases access-related bleeding rates and life-threatening vascular complications.
引用
收藏
页码:850 / 855
页数:6
相关论文
共 50 条
  • [1] ULTRASOUND-GUIDED CANNULATION OF THE FEMORAL VEIN IN ELECTROPHYSIOLOGICAL PROCEDURES: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Sobolev, Maria
    Shiloh, Ariel
    Di Biase, Luigi
    Slovut, David
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 730 - 730
  • [2] Ultrasound-Guided Subclavian Vein Catheterization: A Systematic Review and Meta-Analysis
    Lalu, Manoj M.
    Fayad, Ashraf
    Ahmed, Osman
    Bryson, Gregory L.
    Fergusson, Dean A.
    Barron, Carly C.
    Sullivan, Patrick
    Thompson, Calvin
    CRITICAL CARE MEDICINE, 2015, 43 (07) : 1498 - 1507
  • [3] Application of ultrasound-guided radial artery cannulation in paediatric patients: A systematic review and meta-analysis
    Huang, Hua-ping
    Zhao, Wen-jun
    Wen, Fang
    Li, Xiao-yu
    AUSTRALIAN CRITICAL CARE, 2021, 34 (04) : 388 - 394
  • [4] Ultrasound-guided radial artery cannulation in adult and paediatric populations: a systematic review and meta-analysis
    White, Leigh
    Halpin, Alice
    Turner, Marianne
    Wallace, Laurent
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (05) : 610 - 617
  • [5] Ultrasound-guided cannulation of the femoral vein for acute haemodialysis access
    Kwon, TH
    Kim, YL
    Cho, DK
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1997, 12 (05) : 1009 - 1012
  • [6] "Evidence" for Ultrasound-Guided Femoral Vein Cannulation in Infants and Children?
    Pivalizza, Evan G.
    Maposa, Douglas
    ANESTHESIA AND ANALGESIA, 2011, 112 (04): : 991 - 992
  • [7] EFFICACY OF ULTRASOUND-GUIDED PERIPHERAL INTRAVENOUS CANNULATION VERSUS STANDARD OF CARE: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Ktran, Quincy
    Fairchild, Matthew
    Yardi, Isha
    Mirda, Danielle
    Markin, Katherine
    Pourmand, A. L., I
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (11): : 3068 - 3078
  • [8] Ultrasound-Guided Catheterization of the Femoral Artery: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Sobolev, Maria
    Slovut, David P.
    Chang, Alfredo Lee
    Shiloh, Ariel L.
    Eisen, Lewis A.
    JOURNAL OF INVASIVE CARDIOLOGY, 2015, 27 (07): : 318 - 323
  • [9] Efficacy of ultrasound-guided pharmacopuncture: A systematic review and meta-analysis
    Lee, Jinho
    Lee, Sook-Hyun
    Lee, Yoon Jae
    Kim, Ju Yeon
    Heo, In
    Cho, Jae-Heung
    Seo, Byung-Kwan
    Ko, Dong Kun
    Ha, In-Hyuk
    MEDICINE, 2025, 104 (11)
  • [10] Point-of-Care Ultrasound-Guided Cannulation of Arteriovenous Fistula Comparison with Standard Cannulation Technique: A Systematic Review and Meta-Analysis
    Santos Pinto, Luis Claudio
    Da Luz, Jiandra
    Barbosa, Lucas
    Udoma-Udofa, Ofonime Chantal
    de Magalhaes Leal Moreira, Joao Lucas
    Luborrigueiro, Lucianna Borrigueiro
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):