A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction

被引:17
|
作者
Dang, Jun [1 ]
Gu, Xuejun [1 ]
Pan, Tinsu [2 ]
Wang, Jing [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
C-ARM CT; RESPIRATORY MOTION; DYNAMIC CT; CARDIAC CT; PHASE; MODEL; REGISTRATION; RADIOTHERAPY; ALGORITHMS;
D O I
10.1016/j.ijrobp.2014.10.029
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the performance of a 4-dimensional (4-D) cone-beam computed tomographic (CBCT) reconstruction scheme based on simultaneous motion estimation and image reconstruction (SMEIR) through patient studies. Methods and Materials: The SMEIR algorithm contains 2 alternating steps: (1) motion-compensated CBCT reconstruction using projections from all phases to reconstruct a reference phase 4D-CBCT by explicitly considering the motion models between each different phase and (2) estimation of motion models directly from projections by matching the measured projections to the forward projection of the deformed reference phase 4D-CBCT. Four lung cancer patients were scanned for 4 to 6 minutes to obtain approximately 2000 projections for each patient. To evaluate the performance of the SMEIR algorithm on a conventional 1-minute CBCT scan, the number of projections at each phase was reduced by a factor of 5, 8, or 10 for each patient. Then, 4D-CBCTs were reconstructed from the down-sampled projections using Feldkamp-Davis-Kress, total variation (TV) minimization, prior image constrained compressive sensing (PICCS), and SMEIR. Using the 4D-CBCT reconstructed from the fully sampled projections as a reference, the relative error (RE) of reconstructed images, root mean square error (RMSE), and maximum error (MaxE) of estimated tumor positions were analyzed to quantify the performance of the SMEIR algorithm. Results: The SMEIR algorithm can achieve results consistent with the reference 4D-CBCT reconstructed with many more projections per phase. With an average of 30 to 40 projections per phase, the MaxE in tumor position detection is less than 1 mm in SMEIR for all 4 patients. Conclusion: The results from a limited number of patients show that SMEIR is a promising tool for high-quality 4D-CBCT reconstruction and tumor motion modeling. (C) 2015 Elsevier Inc.
引用
收藏
页码:410 / 418
页数:9
相关论文
共 50 条
  • [1] Advanced 4-dimensional cone-beam computed tomography reconstruction by combining motion estimation, motion-compensated reconstruction, biomechanical modeling and deep learning
    Zhang, You
    Huang, Xiaokun
    Wang, Jing
    [J]. VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2019, 2 (01)
  • [2] Advanced 4-dimensional cone-beam computed tomography reconstruction by combining motion estimation, motion-compensated reconstruction, biomechanical modeling and deep learning
    You Zhang
    Xiaokun Huang
    Jing Wang
    [J]. Visual Computing for Industry, Biomedicine, and Art, 2
  • [3] Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. MEDICAL PHYSICS, 2013, 40 (10)
  • [4] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [5] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-Beam CT
    Wang, J.
    Gu, X.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] Joint Motion Estimation and Compensation for Four-Dimensional Cone-Beam Computed Tomography Image Reconstruction
    Mo, Ying
    Liu, Jia
    Li, Qian
    Yu, Jiahong
    Zhang, Kunpeng
    Gao, Yang
    Zhang, Hua
    [J]. IEEE ACCESS, 2021, 9 : 147559 - 147569
  • [8] Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, Salim
    Weiss, Elisabeth
    Jan, Nuzhat
    Roman, Nicholas
    Sleeman, William C.
    Fatyga, Mirek
    Christensen, Gary E.
    Zhang, Cheng
    Murphy, Martin J.
    Lu, Jun
    Keall, Paul
    Williamson, Jeffrey F.
    Hugo, Geoffrey D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 372 - 379
  • [9] A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction
    Ali, I.
    Alsbou, N.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 215 - 216
  • [10] A comparison of phase, amplitude, and velocity binning for cone-beam computed tomographic projection-based motion reconstruction
    Becker, Nathan
    Quirk, Sarah
    Kay, Ian
    Braverman, Boris
    Smith, Wendy L.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2013, 3 (04) : E209 - E217