An accurate and parallelizable geometric projector/backprojector for 3D PET image reconstruction

被引:0
|
作者
de la Prieta, R [1 ]
机构
[1] Univ Rey Juan Carlos, ESCET, Dept Informat Estadist & Telemat, Madrid 28933, Spain
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
C code for an accurate projector/backprojector for Positron Emission Tomography (PET) image reconstruction has been developed. Iterative PET image reconstruction methods are supported by a projection/backprojection step built inside of any of such algorithms. It is not surprising that a more precise modeling of the forward process of the measurement will yield better results when solving the inverse problem of image reconstruction. Among the factors that can be include in this forward model are gamma-ray scatter contributions, attenuation, positron range, photon non-collinearity, crystal characteristics. Currently, we only include the geometric tube of response (TOR) modeling for a generic multi-ring scanner device. The elements in the transition matrix are calculated by a high statistics Monte Carlo simulation, taking advantage of the inherent symmetries and then the nonzero elements stored in a run length encoding incremental fashion. The resulting projector/backprojector is a voxel driven implementation. We show some preliminary results for 3D ML-EM reconstructions on synthetic phantom simulated data.
引用
收藏
页码:27 / 38
页数:12
相关论文
共 50 条
  • [1] A hardware projector/backprojector pair for 3D PET reconstruction
    Gac, Nicolas
    Mancini, Stephane
    Desvignes, Michel
    Deboissieu, Florian
    Reilhac, Anthonin
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [2] Two approaches to implementing projector-backprojector pairs for 3D reconstruction from Compton scattered data
    Kim, Soo Mee
    Lee, Jae Sung
    Lee, Mi No
    Lee, Ju Hahn
    Lee, Chun Sik
    Kim, Chan-Hyeong
    Lee, Dong Soo
    Lee, Soo-Jin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 255 - 258
  • [3] A projector/backprojector with slice-to-slice blurring for efficient 3D scatter modeling
    Zeng, GSL
    Bai, CY
    Gullberg, GT
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1731 - 1737
  • [4] Direct 3D PET Image Reconstruction into MR Image Space
    Gravel, Paul
    Verhaeghe, Jeroen
    Reader, Andrew J.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3955 - 3962
  • [5] Fast reconstruction of 3D PET data with accurate statistical modeling
    Comtat, C
    Kinahan, PE
    Defrise, M
    Michel, C
    Townsend, DW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1083 - 1089
  • [6] Fast reconstruction of 3D PET data with accurate statistical modeling
    Comtat, C.
    Kinahan, P.E.
    Defrise, M.
    Michel, C.
    Townsend, D.W.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 2): : 1083 - 1089
  • [7] An efficient parallel architecture for 3D PET image reconstruction
    Chen, CM
    Wang, CY
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 910 - 913
  • [8] Fast iterative image reconstruction of 3D PET data
    Kinahan, PE
    Michel, C
    Defrise, M
    Townsend, DW
    Sibomana, M
    Lonneux, M
    Newport, DF
    Luketich, JD
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1918 - 1922
  • [9] AN EXACT ANALYTIC APPROACH TO 3D PET IMAGE RECONSTRUCTION
    Kao, Chien-Min
    Zou, Yu
    Cho, Seungryong
    Pan, Xiaochuan
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2007, 7 (01) : 35 - 54
  • [10] 3D reconstruction from a single image using geometric constraints
    van den Heuvel, FA
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 1998, 53 (06) : 354 - 368