摘要
Introduction: The early diagnosis of infective endocarditis (IE) is a medical challenge and a multidisciplinary approach is essential to improve its frequently fatal prognosis. Our goal was to evaluate the usefulness of [[F-18]2-fluoro-2-deoxy-D-glucose positron emission tomography (F-18-FDG PET) in the diagnosis of this disease. Materials and Methods: We prospectively assessed 43 patients (five female and 38 male) with clinical suspicion of IE between 2014 and 2017. All patients underwent transesophageal echocardiography (TEE) and an F-18-FDG PET scan, and the results were compared. A positive PET finding was defined as increased FDG uptake on cardiac valves or intracardiac devices. Results: Out of 43 patients with suspected IE, the diagnosis was confirmed in 30 cases (79.7%). F-18-FDG PET was positive in 24 patients, with 19 showing FDG uptake on cardiac valves (two native and 17 prosthetic) and five on cardiac devices, being concordant with echocardiographic findings in 11 cases. F-18-FDG PET sensitivity was 80%, specificity 92%, positive predictive value (PPV) 96% and negative predictive value (NPV) 66%. Echocardiography presented sensitivity, specificity, PPV and NPV of 36%, 84%, 84% and 36%, respectively. Conclusions: F-18-FDG PET proved to be a sensitive technique with a high diagnostic value in patients with prosthetic valves and intracardiac devices and suspected IE. Its utility decreased dramatically in patients with suspected IE on native valves, in which TEE presented higher sensitivity and thus better diagnostic value. (C) 2019 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U.
引用
收藏
页码:573 / 580
页数:8
相关论文
共 50 条
  • [1] Incidentalomas of the prostate detected by 18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography
    Mannas, Miles P.
    Lee, Taeweon
    Pourghiasian, Maral
    Wilson, Don C.
    Black, Peter C.
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2020, 14 (05): : E180 - E184
  • [2] Infective endocarditis detected by 18F-fluoro-2-deoxy-D-glucose positron emission tomography/computed infection
    Yeh, Chia-Lu
    Liou, Jer-Young
    Chen, Shih-Wei
    Chen, Yen-Kung
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2011, 27 (11): : 528 - 531
  • [3] Evaluation of radiosensitivity by positron emission tomography with 18-fluoro-2-deoxy-D-glucose in patients affected by uterine neoplasms
    Frezza, P
    Silvestro, G
    Elmo, M
    Panico, M
    Mainolfi, C
    CYCLOTRONS AND THEIR APPLICATIONS 1998, 1999, : 80 - 82
  • [4] 18F-fluoro-2-deoxy-D-glucose positron emission tomography and positron emission tomography/computed tomography imaging of malignant pleural mesothelioma
    Subramaniam, R. M.
    Wilcox, B.
    Aubry, M. C.
    Jett, J.
    Peller, P. J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (02) : 160 - 169
  • [5] 18-Fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography scan for monitoring the therapeutic response in experimental Staphylococcus aureus foreign-body osteomyelitis
    Sofia Chatziioannou
    Odysseas Papamichos
    Maria N. Gamaletsou
    Alexandros Georgakopoulos
    Nikolaos G. Kostomitsopoulos
    Sofia Tseleni-Balafouta
    Joseph Papaparaskevas
    Thomas J. Walsh
    Spiros G. Pneumaticos
    Nikolaos V. Sipsas
    Journal of Orthopaedic Surgery and Research, 10
  • [6] Evaluation of radiosensitivity by positron emission tomography with 18-fluoro-2-deoxy-D-glucose in the patients affected by uterine neoplasms.
    Frezza, P
    Silvestro, G
    Elmo, M
    Panico, M
    Mainolfi, C
    SYNTHESIS AND APPLICATIONS OF ISOTOPICALLY LABELLED COMPOUNDS 1997, 1998, : 641 - 643
  • [7] 18-Fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography scan for monitoring the therapeutic response in experimental Staphylococcus aureus foreign-body osteomyelitis
    Chatziioannou, Sofia
    Papamichos, Odysseas
    Gamaletsou, Maria N.
    Georgakopoulos, Alexandros
    Kostomitsopoulos, Nikolaos G.
    Tseleni-Balafouta, Sofia
    Papaparaskevas, Joseph
    Walsh, Thomas J.
    Pneumaticos, Spiros G.
    Sipsas, Nikolaos V.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [8] 2-Deoxy-2-[18F]fluoro-D-glucose-positron emission tomography and positron emission tomography/computed tomography diagnosis of patients with recurrent papillary thyroid cancer
    Iagaru, Andrei
    Masamed, Rinat
    Singer, Peter A.
    Conti, Peter S.
    MOLECULAR IMAGING AND BIOLOGY, 2006, 8 (05) : 309 - 314
  • [9] 2-Deoxy-2-[18F]fluoro-d-glucose-Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Diagnosis of Patients with Recurrent Papillary Thyroid Cancer
    Andrei Iagaru
    Rinat Masamed
    Peter A. Singer
    Peter S. Conti
    Molecular Imaging and Biology, 2006, 8 : 309 - 314
  • [10] Clinical application of 18F-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in breast cancer
    Bernsdorf, M.
    Graff, J.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2014, 34 (06) : 426 - 433