High performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine and its three metabolites in human plasma

被引:51
|
作者
Liu, Wen [1 ]
Cai, Hua-lin [1 ]
Li, Huan-de [1 ]
机构
[1] Cent S Univ, Xiang Ya Hosp 2, Clin Pharmaceut Res Lab, Changsha 410011, Hunan, Peoples R China
关键词
venlafaxine; metabolite; HPLC-MS/ESI;
D O I
10.1016/j.jchromb.2006.12.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its three metabolites O-desmethylvenlafaxine (ODV), N-desmethylvenlafaxine (NDV) and NO-didesmethylvenlafaxine (DDV) in human plasma has been developed and validated. Estazolam was used as the internal standard. The compounds and internal standard were extracted from plasma by a liquid-liquid extraction. The HPLC separation of the analytes was performed on a Thermo BDS HYPERSIL C-18 (250 mm x 4.6 mm, 5 mu m, USA) column, using a gradient elution program with solvents constituted of water (ammonium acetate: 30 mmol/l, formic acid 2.6 mmol/l and trifluoroacetic acid 0.13 mmol/l) and acetonitrile (60:40, V/V) at a flow-rate of 1.0 ml/min. All of the analytes were eluted within 6 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and were detected in the selected ion recording (SIR) mode. Calibration curves in spiked whole blood were linear from 4.0-700 ng/ml, 2.0-900 ng/ml, 3.0-800ng/ml and 2.0-700ng/ml for VEN, ODV, NDV and DDV, respectively, all of them with coefficients of determination above 0.9991. The average extraction recoveries for all the four analytes were above 77%. The methodology recoveries were higher than 91%. The limits of detection were 0.4, 0.2, 0.3, and 0.2 ng/ml for VEN, ODV, NDV and DDV, respectively. The intra- and inter-day variation coefficients were less than 11%. The method is accurate, sensitive and reliable for the pharmacokinetic study of venlafaxine, as well as therapeutic drug monitoring (TDM). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [1] Simultaneous determination of fluoxetine, citalopram, paroxetine, venlafaxine in plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI)
    He, J
    Zhou, ZL
    Li, HD
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01): : 33 - 39
  • [2] Determination of ambroxol in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI)
    Su Fenli
    Wang Feng
    Gao Wei
    Li Huande
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 364 - 368
  • [3] Simultaneous determination of quetiapine and three metabolites in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Li, KY
    Cheng, ZN
    Li, X
    Bai, XL
    Zhang, BK
    Wang, F
    Li, HD
    ACTA PHARMACOLOGICA SINICA, 2004, 25 (01) : 110 - 114
  • [5] Determination of isotretinoin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Wu, Lili
    Wu, Jingjing
    Zhou, Ke
    Cheng, Fang
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (02) : 324 - 329
  • [6] Determination of enalapril in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Yoon, KH
    Kim, W
    Park, J
    Kim, HJ
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (06): : 878 - 880
  • [7] Determination of mianserin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS): Application to a bioequivalence study in Chinese volunteers
    Xu, Ping
    Li, Huan-De
    Chen, Ben-Mei
    Ma, Ning
    Yan, Miao
    Zhu, Yun-Gui
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) : 994 - 999
  • [8] Determination of raltitrexed in human plasma by high performance liquid chromatography-electrospray ionization-mass spectrometry
    Hu, Jingjing
    Ding, Li
    Song, Qinxin
    Gao, Ying
    Qing, Shukui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 147 - 153
  • [9] Determination of oxatomide in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    She, Xiaodong
    Wu, Lili
    Wei, Huilin
    Liu, Weida
    Chen, Yun
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 746 - 752
  • [10] High-performance liquid chromatography-electrospray ionization mass spectrometry determination of mitiglinide in human plasma and its pharmacokinetics
    Liang, Jiabi
    Tian, Yuan
    Zhang, Zunjian
    Feng, Shudan
    Zhao, Yanan
    Mao, Guoguang
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (02): : 171 - 177