Optimization of ozone dosage in an ozone contact tank using a numerical model

被引:3
|
作者
Mao, Yuqin [1 ]
Qi, Shengqi [2 ]
Guo, Xianfen [3 ]
Yang, Hongwei [4 ]
Xie, Yuefeng F. [3 ,5 ]
机构
[1] Zhejiang Shuren Univ, Coll Biol & Environm Engn, Hangzhou 310015, Peoples R China
[2] Zhejiang Gongshang Univ, Sch Environm Sci & Engn, Zhejiang Prov Key Lab Solid Waste Treatment & Rec, Hangzhou 310012, Peoples R China
[3] Tsinghua Univ, Sch Environm, Beijing 100084, Peoples R China
[4] Res Inst Environm Innovat Suzhou, Suzhou 215163, Peoples R China
[5] Penn State Univ, Environm Engn Programs, Middletown, PA 17057 USA
关键词
Ozone contact tank; Numerical model; Ratio of ozone dosage; Ozone decomposition rate; Ozone consumption amount; Ozone absorption rate; Ozone utilization rate; WASTE-WATER; OXIDATION-KINETICS; DISSOLVED OZONE; DRINKING-WATER; OZONATION; DISINFECTION; DECOMPOSITION; PRETREATMENT; PERFORMANCE; FILTRATION;
D O I
10.1007/s11356-021-13917-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozone has been widely applied in drinking water and wastewater treatment plants, and it is essential to determine the ozone dosage and its ratio in ozone contact tank to increase the ozone absorption and utilization rates. Batch experiments were performed to determine the first-order reaction rate coefficient of ozone (k(1)) in different raw water qualities. Results showed that k(1) had an exponential decaying relationship with the ozone consumption amount (Delta O-3). Based on the ozone mass transfer and decomposition kinetics, a numerical model was developed to optimize the total ozone dosage and its ratio in three aeration parts by calculating the ozone absorption and utilization rates in an ozone contact tank. The ozone absorption rate was little affected by the water quality, and an even distribution of ozone could greatly increase the ozone absorption rate. However, the ozone utilization rate was tightly related with the water quality. For waters that consumed ozone quickly, ozone should be dosed equally in three aeration parts to increase the ozone utilization rate up to 94.3%. Otherwise, more ozone should be dosed in the first aeration part. An increase in ozone utilization rate would induce an increase in the degree of water purification. This model could give theoretical support for the determination of ozone dosage and its ratio in water treatment plants rather than experience.
引用
收藏
页码:44987 / 44997
页数:11
相关论文
共 50 条
  • [1] Optimization of ozone dosage in an ozone contact tank using a numerical model
    Yuqin Mao
    Shengqi Qi
    Xianfen Guo
    Hongwei Yang
    Yuefeng F. Xie
    Environmental Science and Pollution Research, 2021, 28 : 44987 - 44997
  • [2] The development of an ozone contact tank simulation model
    Murrer, J
    Gunstead, J
    Lo, S
    OZONE-SCIENCE & ENGINEERING, 1995, 17 (06) : 607 - 617
  • [3] Effect of-ozone dosage for removal of model compounds by ozone/GAC treatment
    Chang, EE
    Liang, CH
    Ko, YW
    Chiang, PC
    OZONE-SCIENCE & ENGINEERING, 2002, 24 (05) : 357 - 367
  • [4] Reduction of ozone dosage by using ozone in ultrafine bubbles to reduce sludge volume
    Hashimoto, Kurumi
    Kubota, Narumi
    Okuda, Tetsuji
    Nakai, Satoshi
    Nishijima, Wataru
    Motoshige, Hiroshi
    CHEMOSPHERE, 2021, 274
  • [5] The influence of ozone dosage, exposure time and contact temperature of ozone in controlling food quality (case study: tofu)
    Karamah, Eva Fathul
    Najeges, Rana Rezeki
    Zahirsyah, Muhammad Zaki
    13TH JOINT CONFERENCE ON CHEMISTRY (13TH JCC), 2019, 509
  • [6] Optimization of the ozone dosage at the drinking water treatment plant of Kluizen
    Cromphout, Jan
    Goethals, Stefanie
    Verdickt, Liesbeth
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2013, 13 (06): : 1569 - 1575
  • [7] A numerical model of the ozone chemistry in the stratosphere.
    Fonseca, AD
    Campinho, MA
    Arbilla, G
    Correa, SM
    QUIMICA NOVA, 1996, 19 (04): : 361 - 371
  • [8] OZONE DISINFECTION OF PRIMARY EFFLUENT USING A STIRRED TANK REACTOR
    CAVERSON, DL
    FINCH, GR
    SMITH, DW
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1986, 13 (05) : 510 - 516
  • [9] Adsorption and ozone dosage of the air using the gel of chilled silicon
    Briner, E
    HELVETICA CHIMICA ACTA, 1938, 21 : 1218 - 1221
  • [10] Effect of ozone on SS water tank
    不详
    MATERIALS PERFORMANCE, 2000, 39 (12) : 76 - 76