Dynamic Contrast-Enhanced Breast MRI at 7 Tesla Utilizing a Single-loop Coil: A Feasibility Trial

被引:27
|
作者
Umutlu, Lale [1 ,2 ,4 ]
Maderwald, Stefan [1 ,2 ,4 ]
Kraff, Oliver [1 ,2 ,4 ]
Theysohn, Jens M. [1 ,2 ,4 ]
Kuemmel, Sherko [3 ]
Hauth, Elke A. [1 ,2 ,4 ]
Forsting, Michael [1 ,2 ,4 ]
Antoch, Gerald [1 ,2 ,4 ]
Ladd, Mark E. [1 ,2 ,4 ]
Quick, Harald H. [1 ,2 ,4 ]
Lauenstein, Thomas C. [1 ,2 ,4 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Neuroradiol, D-45122 Essen, Germany
[3] Univ Hosp Essen, Dept Gynaecol & Obstet, D-45122 Essen, Germany
[4] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Duisburg, Germany
关键词
Breast MRI; ultra high-field imaging; high-field breast MRI; breast imaging; DIAGNOSTIC-ACCURACY; SPECTROSCOPY; INHOMOGENEITY; 1.5T;
D O I
10.1016/j.acra.2010.03.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. Material and Methods: A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Results: Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. Conclusions: This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength.
引用
收藏
页码:1050 / 1056
页数:7
相关论文
共 50 条
  • [1] Dynamic Contrast-Enhanced Renal MRI at 7 Tesla Preliminary Results
    Umutlu, Lale
    Kraff, Oliver
    Orzada, Stephan
    Fischer, Anja
    Kinner, Sonja
    Maderwald, Stefan
    Antoch, Gerald
    Quick, Harald H.
    Forsting, Michael
    Ladd, Mark E.
    Lauenstein, Thomas C.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 425 - 433
  • [2] Feasibility of Contrast-enhanced and High-resolution 7 Tesla MRI in Patients with Suspicious Breast Lesions
    Stehouwer, B. L.
    Klomp, D. W. J.
    Luijten, P. R.
    Houwert, K. A. F.
    van Diest, P. J.
    Mali, W. P. T. M.
    van den Bosch, M. A. A. J.
    Veldhuis, W. B.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S70 - S70
  • [3] High Temporal Resolution Dynamic Contrast-Enhanced MRI at 7 Tesla: A Feasibility Study with Mouse Liver Model
    Hartono, S.
    Thng, C. H.
    Ng, Q. S.
    Yong, C. X.
    Yang, C. -T.
    Shi, W.
    Chuang, K. H.
    Koh, T. S.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2788 - 2791
  • [4] Dynamic contrast-enhanced and ultra-high-resolution breast MRI at 7.0 Tesla
    Stehouwer, Bertine L.
    Klomp, Dennis W. J.
    van den Bosch, Maurice A. A. J.
    Korteweg, Mies A.
    Gilhuijs, Kenneth G. A.
    Witkamp, Arjen J.
    van Diest, Paul J.
    Houwert, Karel A. F.
    van der Kemp, Wybe J. M.
    Luijten, Peter R.
    Mali, W. P. Th. M.
    Veldhuis, Wouter B.
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 2961 - 2968
  • [5] Dynamic contrast-enhanced and ultra-high-resolution breast MRI at 7.0 Tesla
    Bertine L. Stehouwer
    Dennis W. J. Klomp
    Maurice A. A. J. van den Bosch
    Mies A. Korteweg
    Kenneth G. A. Gilhuijs
    Arjen J. Witkamp
    Paul J. van Diest
    Karel A. F. Houwert
    Wybe J. M. van der Kemp
    Peter R. Luijten
    W. P. Th. M. Mali
    Wouter B. Veldhuis
    European Radiology, 2013, 23 : 2961 - 2968
  • [6] Dynamic Contrast-Enhanced MRI: Feasibility and Utility in Abdominal Disease
    Sandrasegaran, K.
    Akisik, F.
    Lin, C.
    Hutchins, G.
    Tann, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [7] Feasibility of multiple-mouse dynamic contrast-enhanced MRI
    Ramirez, Marc S.
    Ragan, Dustin K.
    Kundra, Vikas
    Banksonl, James A.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 610 - 615
  • [8] Low-Dose, Contrast-Enhanced Mammography Compared to Contrast-Enhanced Breast MRI: A Feasibility Study
    Clauser, Paola
    Baltzer, Pascal A. T.
    Kapetas, Panagiotis
    Hoernig, Mathias
    Weber, Michael
    Leone, Federica
    Bernathova, Maria
    Helbich, Thomas H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (02) : 589 - 595
  • [9] Ultrafast Dynamic Contrast-enhanced MRI of the Breast: How Is It Used?
    Kataoka, Masako
    Honda, Maya
    Ohashi, Akane
    Yamaguchi, Ken
    Mori, Naoko
    Goto, Mariko
    Fujioka, Tomoyuki
    Mori, Mio
    Kato, Yutaka
    Satake, Hiroko
    Iima, Mami
    Kubota, Kazunori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (01) : 83 - 94
  • [10] Dynamic contrast-enhanced MRI in the diagnosis and management of breast cancer
    Turnbull, Lindsay W.
    NMR IN BIOMEDICINE, 2009, 22 (01) : 28 - 39