Nitrite electro-oxidation mediated by Co(II)-[tetra(4-aminophenyl)porphyrin]-modified electrodes: behavior as an amperometric sensor

被引:19
|
作者
Rios, Roxana [1 ,3 ]
Marin, America [2 ,4 ]
Ramirez, Galo [1 ,3 ]
机构
[1] Pontificia Univ Catolica Chile, Fac Quim, Dept Quim Inorgan, Correo 22, Santiago, Chile
[2] Univ Santiago Chile, Fac Quim & Biol, Dept Quim Ios Materi, Casilla 40, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Fac Quim, Dept Quim Inorgan, Santiago, Chile
[4] Univ Santiago Chile, Fac Quim & Biol, Dept Quim Mat, Santiago, Chile
关键词
Nitrite electro-oxidation; Modified electrodes; Amperometric sensor; Porphyrins; Electrocatalysis; CHEMICALLY-MODIFIED ELECTRODES; FLOW-INJECTION DETERMINATION; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL REDUCTION; PORPHYRIN; NITRATE; OXIDE; CU;
D O I
10.1080/00958971003802091
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Electro-oxidation of nitrite mediated by Co(II)-[tetra(4-aminophenyl)porphyrin]-modified electrodes (4-CoTAPP) is presented in this article. Catalytic activity of electrodes modified with porphyrin polymeric films (poly-4-CoTAPP) and with multilayer of monomers (m-4-CoTAPP) for the oxidation of nitrite was compared. The number of cycles for the electrosynthesis of poly-4-CoTAPP determines the activity of the electrode toward nitrite oxidation because the system loses its catalytic activity as the number of polymerization cycles increases above 15. The effect of pH on activity is also reported. The response for the nitrite oxidation of electrodes modified with 4-CoTAPP and with metal-free ligand, that is, tetra(4-aminophenyl)porphyrin, either as multilayer of monomers or as polymer (m-4-H2TAPP and poly-4-H2TAPP, respectively), was compared. An increase of activity in the presence of the metal was found. Furthermore, when the device was tested as an amperometric sensor for different nitrite concentrations under the optimum working conditions, only poly-4-CoTAPP exhibited a linear response throughout the concentration range studied with a reasonably low limit of detection, while m-4-CoTAPP and poly-H2TAPP systems have no linear response throughout the range of concentration. Finally, the number of electrons involved and the Tafel slope for the reaction were estimated.
引用
收藏
页码:1283 / 1294
页数:12
相关论文
共 30 条
  • [1] Electrocatalytic oxidation of sulfite at polymeric iron tetra (4-aminophenyl) porphyrin -: modified electrode
    Lucero, M
    Ramírez, G
    Riquelme, A
    Azocar, I
    Isaacs, M
    Armijo, F
    Förster, JE
    Trollund, E
    Aguirre, MJ
    Lexa, D
    JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 2004, 221 (1-2) : 71 - 76
  • [2] CHEMICALLY-MODIFIED ELECTRODE BASED ON POLY[TETRA(4-AMINOPHENYL)PORPHYRIN] AS A PH SENSOR
    YUAN, R
    CHAI, YQ
    SHEN, GL
    YU, RQ
    TALANTA, 1993, 40 (08) : 1255 - 1259
  • [3] Electro-Oxidation of Nitrite Using an Oxidized Glassy Carbon Electrode as Amperometric Sensor
    Camila Canales
    Monica Antilén
    Manuel Chapa
    Rodrigo Del Río
    Galo Ramírez
    Electrocatalysis, 2015, 6 : 300 - 307
  • [4] Electro-Oxidation of Nitrite Using an Oxidized Glassy Carbon Electrode as Amperometric Sensor
    Canales, Camila
    Antilen, Monica
    Chapa, Manuel
    Del Rio, Rodrigo
    Ramiez, Galo
    ELECTROCATALYSIS, 2015, 6 (03) : 300 - 307
  • [5] Electro-oxidation of chlorophenols at glassy carbon electrodes modified with polyNi(II)complexes
    Berrios, Cristhian
    Marco, Jose F.
    Gutierrez, Claudio
    Soledad Ureta-Zanartu, Maria
    ELECTROCHIMICA ACTA, 2009, 54 (26) : 6417 - 6425
  • [6] Electro-oxidation of coal on NiO and/or Co3O4 modified TiO2/Pt electrodes
    Wang, Chao
    Zhao, Yonggang
    Zhou, Wei
    Liu, Huaiyou
    Yin, Renhe
    ELECTROCHIMICA ACTA, 2011, 56 (18) : 6299 - 6304
  • [7] Covalent functionalization and characterization of Single-walled carbon nanotubes with Cu (II) complexes of meso-tetra(4-aminophenyl)porphyrin
    Veetil, Vyshnavi T.
    Prabhavathi, G.
    Yamuna, R.
    INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2018), 2019, 577
  • [8] Clinical available circulating tumor cell assay based on tetra(4-aminophenyl) porphyrin mediated reduced graphene oxide field effect transistor
    Hu, Shihui
    Wang, Zhongrong
    Gu, Yajun
    Li, Yueguo
    Jia, Yunfang
    ELECTROCHIMICA ACTA, 2019, 313 : 415 - 422
  • [9] Amperometric sensor for nitrite using a glassy carbon electrode modified with alternating layers of iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin and cobalt(II) tetrasulfonated phthalocyanine
    Santos, Wilney J. R.
    Sousa, Aline L.
    Luz, Rita C. S.
    Damos, Flavio S.
    Kubota, Lauro T.
    Tanaka, Auro A.
    Tanaka, Sonia M. C. N.
    TALANTA, 2006, 70 (03) : 588 - 594
  • [10] Electrochemical reduction of nitrite at polymeric Co(II)-tetra-3-amino-phenyl-porphyrin modified electrode
    Martin, Cristian San
    Dreyse, Paulina
    Garcia, Camilo
    Calfuman, Karla
    Villagra, Diego
    Isaacs, Mauricio
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2007, 52 (04): : 1305 - 1308