Numerical electromagnetic field analysis on lightning surge response of tower with shield wire

被引:73
|
作者
Baba, Y [1 ]
Ishii, M
机构
[1] Doshisha Univ, Dept Elect Engn, Kyoto 6100321, Japan
[2] Univ Tokyo, Inst Ind Sci, Minato Ku, Tokyo 106, Japan
关键词
coupling coefficient; EMTP; lightning surge; numerical electromagnetic field analysis; tower footing impedance; tower surge impedance;
D O I
10.1109/61.871367
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lightning surge characteristics of a transmission line comprising a tower, a shield wire and phase conductors are studied with the help of NEC-2, A tower struck by a lightning stroke behaves as an antenna until a traveling wave makes several roundtrips in the tower During this interval, the tower footing impedance appears to be higher than the footing resistance, and the coupling coefficient between a shield wire and a phase conductor is much lower than that in the TEM mode. These affect the estimation of insulator voltages of transmission towers subject to lightning currents having short rise times. On the basis of these findings, the parameters in the multistory tower model, which has been used widely in EMTP multi-conductor analyzes, are newly proposed.
引用
收藏
页码:1010 / 1015
页数:6
相关论文
共 50 条
  • [1] Numerical electromagnetic field analysis of tower surge response
    Ishii, M
    Baba, YU
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) : 483 - 488
  • [2] Numerical electromagnetic field analysis is on measuring methods of tower surge impedance
    Baba, Y
    Ishii, M
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (02) : 630 - 635
  • [3] TOWER MODELING FOR LIGHTNING SURGE ANALYSIS USING ELECTROMAGNETIC TRANSIENTS PROGRAM
    ALMEIDA, ME
    DEBARROS, MTC
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1994, 141 (06) : 637 - 639
  • [4] Lightning Surge Analysis by EMTP and Numerical Electromagnetic Analysis Method
    Ametani, Akihiro
    [J]. 2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [5] Lightning surge response analysis of concrete pole using the electromagnetic field method
    Hintamai, S
    Hokierti, J
    [J]. 2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 568 - 573
  • [6] Surge Voltage and Environmental Electromagnetic Field Analysis for HV Composite Transmission Tower under Lightning Strokes
    Huangfu, Youpeng
    Wang, Shuhong
    Tao, Xi
    Wang, Song
    Yang, Bin
    Wang, Guolin
    Zhang, Yuxi
    [J]. 2014 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2014, : 445 - 450
  • [7] Computation of power line tower lightning surge impedance using the electromagnetic field method
    Gao, Changzheng
    Li, Lin
    Li, Bing
    Zhao, Zhibin
    [J]. 2006 17TH INTERNATIONAL ZURICH SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, 2006, : 124 - +
  • [8] Lightning surge analysis on vertical tower using electromagnetic transient program (EMTP)
    Rahman, Mostafizur
    Hossain, Foisal
    Hossain, A. B. M. Aowlad
    Goni, Osman
    [J]. ICECE 2006: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, 2006, : 17 - +
  • [9] Analysis of Lightning Surge Characteristics on Transmission Tower
    Yusuf, M. S.
    Ahmad, M.
    Rashid, M. A.
    Goni, M. O.
    [J]. ENGINEERING LETTERS, 2015, 23 (01) : 29 - 39
  • [10] Numerical Analysis of Electromagnetic Field, Heat and Thermal Stress of a Transmission Line Surge Arrester for Lightning Currents
    Nishimura, Yoshiki
    Baba, Yoshihiro
    Shinjo, Kazuo
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 18 (07) : 1208 - 1210