Wide-Area Voltage Monitoring and Optimization

被引:31
|
作者
Li, Haoen [1 ]
Bose, Anjan [2 ]
Venkatasubramanian, Vaithianathan [2 ]
机构
[1] Grid Shanghai Municipal Elect Power Co, Shanghai 200122, Peoples R China
[2] Washington State Univ, Pullman, WA 99163 USA
基金
美国国家科学基金会;
关键词
Parallel optimization; phasor measurement units (PMU); voltage stability index (VSI); wide-area measurement system (WAMS); POWER; SYSTEM;
D O I
10.1109/TSG.2015.2467215
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the power demand becomes higher all over the world, transmission lines are often carrying electric power near their limits, which can cause power systems to be operated under serious stress. Voltage collapse is one of the more critical problems that impacts power system operational security and many of the recent major blackouts were caused, at least partially, by voltage collapse. Therefore, a fast and accurate voltage stability monitor is necessary for the modern system, together with a fast calculation of possible remedial actions. The development and application of wide-area measurement systems established the foundation of online assessment of voltage stability in large-scale power systems. In this paper, a voltage stability (QV) index based on phasor measurements is used to identify the weak buses and a new parallel optimization method that increases this voltage stability margin is introduced. Results on the IEEE standard systems show the accuracy and efficiency of the methods.
引用
收藏
页码:785 / 793
页数:9
相关论文
共 50 条
  • [1] Linearized voltage stability index for wide-area voltage monitoring and control
    Gu, Wei
    Wan, Qiulan
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (04) : 333 - 336
  • [2] Voltage-stability monitoring using wide-area measurement systems
    Genet, Benjamin
    Maun, Jean-Claude
    [J]. 2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1712 - 1717
  • [3] Online Monitoring of Wide-area Voltage Stability Based on Short Circuit Capacity
    Huang Lei
    Xu Jian
    Sun Yuanzhang
    Cui Ting
    Dai Fei
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [4] Wide-area protection against voltage collapse
    Ingelsson, B
    Lindstrom, PO
    Karlsson, D
    Runvik, G
    Sjodin, JO
    [J]. IEEE COMPUTER APPLICATIONS IN POWER, 1997, 10 (04): : 30 - 35
  • [5] Optimal PMU Placement for Wide-Area Monitoring Using Chemical Reaction Optimization
    Xu, Jin
    Wen, Miles H. F.
    Li, Victor O. K.
    Leung, Ka-Cheong
    [J]. 2013 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES (ISGT), 2013,
  • [6] Implementation and Applications of Wide-area monitoring systems
    Larsson, Mats
    Korba, Petr
    Zima, Marek
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 669 - +
  • [7] Fault Location Method Based on Wide-Area Voltage
    Xu, Yan
    Ying, Lu-man
    Zhi, Jing
    Feng, Ren-qing
    [J]. ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 2077 - +
  • [8] Optimization scheme for under-voltage load shedding wide-area configuration and substation-area setting
    School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing
    100044, China
    [J]. Dianwang Jishu, 8 (2333-2339):
  • [9] Optimal Multistage PMU Placement for Wide-Area Monitoring
    Wen, Miles H. F.
    Xu, Jin
    Li, Victor O. K.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) : 4134 - 4143
  • [10] New Applications for Wide-Area Monitoring, Protection and Control
    Mueller, Sven C.
    Kubis, Andreas
    Brato, Sebastian
    Haeger, Ulf
    Rehtanz, Christian
    Goetze, Juergen
    [J]. 2012 3RD IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2012,