Optimized selection of one- and two-stage ejectors under design and off-design conditions

被引:18
|
作者
Chen, Hongjie [1 ,2 ]
Zhu, Jiahua [1 ]
Lu, Wei [3 ]
机构
[1] Sichuan Univ, Sch Chem Engn, Chengdu 610065, Sichuan, Peoples R China
[2] Guilin Univ Aerosp Technol, Sch Energy & Bldg Environm, Guilin 541004, Guangxi, Peoples R China
[3] Guangxi Univ, Coll Mech Engn, Nanning 530004, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Ejector; Efficiency; One- and two-stage; Optimized selection; REFRIGERATION SYSTEM; PERFORMANCE; MODEL;
D O I
10.1016/j.enconman.2018.06.113
中图分类号
O414.1 [热力学];
学科分类号
摘要
To provide guidance for the optimized selection of one- and two-stage ejectors, the efficiencies of these two ejectors are compared under design and off-design conditions based on a verified mathematic model. Under design condition, the one-stage ejector presents a higher efficiency at low compression ratios but the two-stage ejector is superior at high compression ratios. The superiority of the two-stage ejector is more obvious at low expansion ratios and at higher compression ratio value, due to lesser mixing loss and more boosting loss in the mixing chamber, respectively. The compression ratio of the equivalent entrainment ratio should be defined as the diacritical point between the high and low expansion ratio, whose value is approximately 1.73 for the R141b ejector. The inevitable loss of mechanical energy in the diffuser causes the crossed efficiencies of the one- and two-stage ejectors. Compared with the one-stage ejector, the two-stage ejector possesses more slow change of efficiency under off-design conditions due to a lesser primary vapor passing through the first stage ejector, obtaining the ability to resist the sharp deterioration in efficiency at single chocking mode. For the typical application of ejector refrigeration system with R141b as the working fluid, it would be best to adopt the two-stage ejector.
引用
收藏
页码:743 / 752
页数:10
相关论文
共 50 条
  • [1] Modeling of two-phase transcritical CO2 ejectors for on-design and off-design conditions
    Taleghani, S. Taslimi
    Sorin, M.
    Poncet, S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 87 : 91 - 105
  • [2] AERODYNAMIC INVESTIGATION OF THE PERFORMANCE OF A TWO STAGE AXIAL TURBINE AT DESIGN AND OFF-DESIGN CONDITIONS
    Abdelfattah, Sherif A.
    Chibli, Hicham A.
    Schobeiri, M. T.
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 7, PTS A-C, 2012, : 775 - 785
  • [4] DYNAMICS OF AN OPTIMIZED ROTOR BLADE AT OFF-DESIGN FLIGHT CONDITIONS
    CHATTOPADHYAY, A
    JONES, H
    JOURNAL OF AIRCRAFT, 1992, 29 (02): : 294 - 296
  • [5] Flow Mechanism of a New Concept Transonic Tandem Fan Stage under the Design and Off-Design Conditions
    Zhou, Chuangxin
    Zhao, Shengfeng
    Lu, Xingen
    AEROSPACE, 2022, 9 (11)
  • [6] Performance of a jaws inlet under off-design conditions
    Gu, Tianlai
    Zhang, Shuai
    Zheng, Yao
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2017, 231 (02) : 294 - 305
  • [7] Theoretical Study of Turbine Stage Characteristics in Off-design Conditions
    Klimko, Marek
    17TH CONFERENCE OF POWER SYSTEM ENGINEERING, THERMODYNAMICS AND FLUID MECHANICS, 2018, 2047
  • [8] SIMULATION OF MULTI-STAGE COMPRESSOR AT OFF-DESIGN CONDITIONS
    Wang, Feng
    Carnevale, Mauro
    di Mare, Luca
    Gallimore, Simon
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 2A, 2017,
  • [9] Steady and unsteady flow characteristics of a multi-stage centrifugal pump under design and off-design conditions
    Kim J.-H.
    Cho B.-M.
    Kim S.
    Lee Y.-K.
    Choi Y.-S.
    International Journal of Fluid Machinery and Systems, 2019, 12 (01): : 64 - 70
  • [10] CAVITY FLOW MODELING IN AN INDUSTRIAL CENTRIFUGAL COMPRESSOR STAGE AT DESIGN AND OFF-DESIGN CONDITIONS
    Guidotti, Emanuele
    Naldi, Giovanni
    Tapinassi, Libero
    Chockalingam, Valliappan
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 8, PTS A-C, 2012, : 593 - +