Transabdominal fetal pulse oximetry with near-infrared spectroscopy

被引:31
|
作者
Vintzileos, AM [1 ]
Nioka, S
Lake, M
Li, PC
Luo, QM
Chance, B
机构
[1] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Obstet Gynecol & Reprod Sci, New Brunswick, NJ USA
[2] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
[3] Opt Devices Inc, Philadelphia, PA USA
[4] Minist Educ, Key Lab Biomed Photon, Wuhan, Peoples R China
[5] Huazhong Univ Sci & Technol, Dept Opt Engn, Wuhan 430074, Peoples R China
关键词
transabdominal fetal; pulse oximetry;
D O I
10.1016/j.ajog.2004.07.022
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The purpose of this study was to determine the feasibility of noninvasive fetal pulse. oximetry in the human fetus with transabdominal continuous-wave near-infrared spectroscopy. Study design: The instrument has 3 wavelength light-emitting diodes (735, 805, and 850 nm) as light sources and a photomultiplier tube as a detector. This instrument was used in 6 pregnant women (>36 weeks of gestation). First. a fetal heart rate was obtained with a fetal heart rate monitor. Then, the depth of fetal tissue (head) from the maternal abdomen was determined by, ultrasound examination; the distance between the optodes (light source and the detector) set to be approximately twice the depth of the fetus (7-11 cm). The data analysis was based on the modified Beer-Lambert law and the use of optical densities at 135 and 850 nm to obtain the. concentration changes of the oxyhemoglobin and deoxyhemoglobin. The saturation was expressed as the percent of oxygen saturation equal to 100 X oxyhemoglobin/(oxyhemoglobin + deoxyhemoglobin). We recorded the spectroscopy data and the fetal heart rate for approximately 3 to 10 minutes in each patient. Results: The mean oxygen saturation values of each of the 6 individual fetuses ranged from 50% to 74% (overall mean saturation, 61% +/- 14.8% [SD]). Conclusion: This preliminary data indicate that transabdominal fetal pulse oximetry is feasible for human patient application. The measured values were similar to those that are obtained with transvaginal pulse oximetry. Future studies should correlate transabdominally obtained measurements with those measurements that are obtained by transvaginal fetal pulse oximetry. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 50 条
  • [1] Transabdominal fetal pulse oximetry using near-infrared spectroscopy (NIRS)
    Vintzileos, A
    Nioka, S
    Lake, M
    Li, PC
    Luo, QM
    Wang, HM
    Rosen, H
    Chance, B
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S179 - S179
  • [3] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    [J]. ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [4] Detection of hypoxia by near-infrared spectroscopy and pulse oximetry: a comparative study
    Cheung, Amanda
    Tu, Lorna
    Macnab, Andrew
    Kwon, Brian K.
    Shadgan, Babak
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (07)
  • [5] Near-infrared transmittance pulse oximetry with laser diodes
    Silva, SML
    Castilla, MLD
    Martin, JPS
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (03) : 525 - 533
  • [6] Transabdominal measurement of oxygenation of the placenta by near-infrared spectroscopy
    Kakogawa, Jun
    Sumimoto, Kazuhiro
    Kawamura, Takakazu
    Nishiguchi, Tomizo
    Suzuki, Yasuyuki
    Kanayama, Naohiro
    [J]. PLACENTA, 2006, 27 (9-10) : A34 - A34
  • [7] Measurement of placental oxygenation by transabdominal near-infrared spectroscopy
    Kawamura, Takakazu
    Kakogawa, Jun
    Takeuchi, Yasutaka
    Takani, Satoko
    Kimura, Satoshi
    Nishiguchi, Tomizou
    Sugimura, Motoi
    Sumimoto, Kazuhiro
    Kanayama, Naohiro
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2007, 24 (03) : 161 - 166
  • [8] Transabdominal Measurement of Placental Oxygenation by Near-infrared Spectroscopy
    Kakogawa, Jun
    Sumimoto, Kazuhiro
    Kawamura, Takakazu
    Minoura, Shigeki
    Kanayama, Naohiro
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2010, 27 (01) : 25 - 29
  • [9] Transabdominal measurement of oxygenation of the placenta by near-infrared spectroscopy
    Kakogawa, J
    Sumimoto, K
    Ho, E
    Kanayama, N
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2005, 31 (03): : 297 - 301
  • [10] Transabdominal near infrared oximetry of hypoxic stress in fetal sheep brain in utero
    Choe, R
    Durduran, T
    Yu, GQ
    Nijland, MJM
    Chance, B
    Yodh, AG
    Ramanujam, N
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (22) : 12950 - 12954