A Highly Sensitive Hydrogen Peroxide Biosensor Based on Hemoglobin Immobilized on Cadmium Sulfide Quantum Dots/Chitosan Composite Modified Glassy Carbon Electrode

被引:13
|
作者
Butwong, Nutthaya [1 ]
Zhou, Lin [2 ,3 ]
Moore, Eric [2 ,3 ,4 ,5 ]
Srijaranai, Supalax [4 ,5 ]
Luong, John H. T. [2 ,3 ]
Glennon, Jeremy D. [2 ,3 ]
机构
[1] Rajamangala Univ Technol, Fac Sci & Liberal Arts, Dept Appl Chem, Nakhon 30000, Ratchasima, Thailand
[2] Natl Univ Ireland Univ Coll Cork, Innovat Chromatog Grp, ISSC, Dept Chem, Cork, Ireland
[3] Natl Univ Ireland Univ Coll Cork, ABCRF, Cork, Ireland
[4] Khon Kaen Univ, Fac Sci, Dept Chem, Khon Kaen 40002, Thailand
[5] Khon Kaen Univ, Ctr Innovat Chem, Fac Sci, Khon Kaen 40002, Thailand
基金
爱尔兰科学基金会;
关键词
Hemoglobin; Cadmium sulphide; Quantum dots; Chitosan; Hydrogen peroxide; LAYER-BY-LAYER; DIRECT ELECTROCHEMISTRY; FLUORESCENCE PROBE; AQUEOUS-SOLUTION; IONIC LIQUID; CHITOSAN; DOTS; NANOPARTICLES; NANOTUBES; FILMS;
D O I
10.1002/elan.201400353
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An L-cysteine capped cadmium sulfide-chitosan nanocomposite has been synthesized, characterized and used for surface modification of a glassy carbon electrode. With direct electron transfer, hemoglobin (Hb) adsorbed strongly on the nanocomposite and displayed excellent bioelectrocatalysis for H2O2. The biosensor was capable of reducing H2O2 at -0.35 V, with a detection limit of 3.13 nM, linearity in the range of 15 nM to 10 mu M and a response time of less than 2 s. The Michaelis-Menten constant (K-M) was 0.57 nM, attesting high bioelectrocatalysis of immobilized Hb for H2O2. Reproducibility of the fabrication method was very satisfactory with a relative standard deviation of 5.3%. The biosensor lost only 6.5% of its original response after 7 days when stored in a pH 7.4 PBS at 4 degrees C.
引用
收藏
页码:2465 / 2473
页数:9
相关论文
共 50 条
  • [1] A novel hydrogen peroxide biosensor based on hemoglobin immobilized on magnetic chitosan microspheres modified electrode
    Lai, Guo-Song
    Zhang, Hai-Li
    Han, De-Yan
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) : 497 - 503
  • [2] Highly sensitive and selective hydrogen peroxide biosensor based on hemoglobin immobilized at multiwalled carbon nanotubes-zinc oxide composite electrode
    Palanisamy, Selvakumar
    Cheemalapati, Srikanth
    Chen, Shen-Ming
    ANALYTICAL BIOCHEMISTRY, 2012, 429 (02) : 108 - 115
  • [3] Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
    ZHANG Jin-lei~(1
    2.Department of Chemistry and Life Science
    Chemical Research in Chinese Universities, 2010, 26 (04) : 541 - 545
  • [4] Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
    Zhang Jin-lei
    Tan Xue-cai
    Zhao Dan-dan
    Tan Sheng-wei
    Huang Zeng-wei
    Mi Yan
    Huang Zai-yin
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (04) : 541 - 545
  • [5] Preparation and characterization of hemoglobin immobilized on graphene quantum dots-chitosan nanocomposite as a sensitive and stable hydrogen peroxide biosensor
    Mohammad-Rezaei R.
    Razmi H.
    Sensor Letters, 2016, 14 (07): : 685 - 691
  • [6] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574
  • [7] A hydrogen peroxide biosensor based on the direct electrochemistry of hemoglobin modified with quantum dots
    Yanxia Xu
    Jiangong Liang
    Chengguo Hu
    Fang Wang
    Shengshui Hu
    Zhike He
    JBIC Journal of Biological Inorganic Chemistry, 2007, 12 : 421 - 427
  • [8] A hydrogen peroxide biosensor based on the direct electrochemistry of hemoglobin modified with quantum dots
    Xu, Yanxia
    Liang, Jiangong
    Hu, Chengguo
    Wang, Fang
    Hu, Shengshui
    He, Zhike
    JOURNAL OF BIOLOGICAL INORGANIC CHEMISTRY, 2007, 12 (03): : 421 - 427
  • [9] A Highly Sensitive Dopamine Sensor Based on Graphene Quantum Dots Modified Glassy Carbon Electrode
    Zheng, Shengbiao
    Huang, Rong
    Ma, Xiaoqing
    Tang, Jing
    Li, Zirong
    Wang, Xuchuan
    Wei, Jumeng
    Wang, Jianfei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (06): : 5723 - 5735
  • [10] Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Immobilized on Fe3O4/Chitosan Modified Glassy Carbon Electrode
    Tan, Xuecai
    Zhang, Jinlei
    Tan, Shengwei
    Zhao, Dandan
    Huang, Zenwei
    Mi, Yan
    Huang, Zaiyin
    ELECTROANALYSIS, 2009, 21 (13) : 1514 - 1520