Automated interpretation of myocardial SPECT perfusion images using artificial neural networks

被引:0
|
作者
Lindahl, D
Palmer, J
Ohlsson, M
Peterson, C
Lundin, A
Edenbrandt, L
机构
[1] Univ Lund, Dept Clin Physiol, Lund, Sweden
[2] Univ Lund, Dept Radiat Phys, S-22101 Lund, Sweden
[3] Univ Lund, Dept Theoret Phys, S-22362 Lund, Sweden
[4] Univ Lund, Dept Radiol, S-22362 Lund, Sweden
关键词
diagnosis; computer-assisted; artificial intelligence; neural networks; ischemic heart disease;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to develop a computer-based method for automatic detection and localization of coronary artery disease (CAD) in myocardial bull's-eye scintigrams. Methods: A population of 135 patients who had undergone both myocardial Tc-99m-sestamibi rest-stress scintigraphy and coronary angiography within 3 mo was studied. Different image data reduction methods, including pixel averaging and two-dimensional Fourier transform, were applied to the bull's-eye scintigrams. After a quantitative and qualitative evaluation of these methods, 30 Fourier components were chosen as inputs to multilayer perceptron artificial neural networks. The networks were trained to detect CAD in two vascular territories, using coronary angiography as gold standard. A "leave one out" procedure was used for training and evaluation. The performance of the networks was compared to those of two human experts. Results: One of the human experts detected CAD in one of two vascular territories, with a sensitivity of 54.4% at a specificity of 70.5%. The sensitivity of the networks was significantly higher at that level of specificity(77.2%, p = 0.0022). The other expert had a sensitivity of 63.2% at a specificity of 61.5%. The networks had a sensitivity of 77.2% (p = 0.038) at this specificity level as well. The differences in sensitivity between human experts and networks for the other vascular territory were all less than 6% and were not statistically significant. Conclusion: Artificial neural networks can detect CAD in myocardial bull's-eye scintigrams with such a high accuracy that the application of neural networks as clinical decision support tools appears to have significant potential.
引用
收藏
页码:1870 / 1875
页数:6
相关论文
共 50 条
  • [1] WeAidU - a decision support system for myocardial perfusion images using artificial neural networks
    Ohlsson, M
    [J]. ARTIFICIAL INTELLIGENCE IN MEDICINE, 2004, 30 (01) : 49 - 60
  • [2] Automated assessment of serial SPECT myocardial perfusion images
    Ami E. Iskandrian
    Ernest V. Garcia
    Tracy Faber
    John J. Mahmarian
    [J]. Journal of Nuclear Cardiology, 2009, 16 : 6 - 9
  • [3] Automated assessment of serial SPECT myocardial perfusion images
    Iskandrian, Ami E.
    Garcia, Ernest V.
    Faber, Tracy
    Mahmarian, John J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (01) : 6 - 9
  • [4] Influence of neural network in interpretation of myocardial perfusion images
    Taegil, K. E.
    Bondouy, M.
    Chaborel, J.
    Djaballah, W.
    Franken, P. R.
    Grandpierre, S.
    Hesse, B.
    Lomsky, M.
    Marie, P. Y.
    Ohlsson, M.
    Poisson, T.
    Richter, J.
    Edenbrandt, L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S280 - S280
  • [5] Patient gender and radiopharmaceutical tracer is of minor importance for the interpretation of myocardial perfusion images using an artificial neural network
    Tägil, K
    Underwood, SR
    Davies, G
    Latus, KA
    Ohlsson, M
    Götborg, CW
    Edenbrandt, L
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (03) : 146 - 150
  • [6] Automated interpretation of ventilation-perfusion lung scintigrams for the diagnosis of pulmonary embolism using artificial neural networks
    Holger Holst
    Karl Åström
    Andreas Järund
    John Palmer
    Anders Heyden
    Frederik Kahl
    Kristina Trägil
    Eva Evander
    Gunnar Sparr
    Lars Edenbrandt
    [J]. European Journal of Nuclear Medicine, 2000, 27 : 400 - 406
  • [7] Automated interpretation of ventilation-perfusion lung scintigrams for the diagnosis of pulmonary embolism using artificial neural networks
    Holst, H
    Åström, K
    Järund, A
    Palmer, J
    Heyden, A
    Kahl, F
    Tägil, K
    Evander, E
    Sparr, G
    Edenbrandt, L
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (04) : 300 - 306
  • [8] Improved myocardial perfusion PET imaging using artificial neural networks
    Wang, Xinhui
    Yang, Bao
    Moody, Jonathan B.
    Tang, Jing
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (14):
  • [9] Improved myocardial perfusion PET imaging using artificial neural networks
    Wang, Xinhui
    Yang, Bao
    Gao, Xiangzhen
    Tang, Jing
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [10] Automated Quantitative Assessment of Myocardial Perfusion in Rodent PET/SPECT Images
    Woo, Sang-Keun
    Lee, Yong Jin
    Kim, Kyeong Min
    Yu, Jung Woo
    Lee, Kyo Chul
    Kim, Min Hwan
    Park, Ji-Ae
    Kang, Joo Hyun
    Kim, Byung Il
    Lim, Sang Moo
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3054 - 3057