Axial compression behavior of precast circular semi-continuous concrete-filled steel tube columns

被引:2
|
作者
Cao, Bing [1 ]
Xie, Mingming [1 ]
Zhu, Longfei [1 ]
Cao, Wancheng [1 ]
Huang, Bo [1 ]
Du, Yihan [1 ]
Wang, Jiawei [1 ]
Yang, Yizhen [1 ]
Wang, Changsheng [1 ]
机构
[1] Anhui Polytech Univ, Coll Civil Engn & Architecture, Beijing Rd 8, Wuhu 241000, Peoples R China
关键词
Precast circular semi-continuous concrete-filled steel tube (PCSCFST) column; confinement; bolt; axial compression; ultimate bearing capacity; SEISMIC BEHAVIOR; PSEUDODYNAMIC TESTS; TURKEY EARTHQUAKE; AUGUST; 17; CONNECTIONS; STRENGTH; PERFORMANCE; BUILDINGS; KOCAELI; MEMBERS;
D O I
10.1177/16878132221107471
中图分类号
O414.1 [热力学];
学科分类号
摘要
To study the axial compression performance of precast circular semi-continuous concrete-filled steel tube (PCSCFST) column, a total of 17 specimens were prepared and tested, including 13 PCSCFST columns and 4 continuous CFST columns. This PCSCFST column is made up of upper and lower steel tubes and outer steel tubes connected by bolts, which has the advantages of easy factory production and convenient transportation. The results showed that shear failure occurred in continuous CFST columns, but not in PCSCFST columns, bolts had obvious influence on failure mode. Maintaining the consistency of the thickness of each steel tube on the specimen can not only improve the local buckling, but also avoid the short plate effect to give full play to the material performance. Moreover, with the increase of steel tube thickness, concrete strength, bolt diameter, reduction of specimen length and pure bolt connection instead of bolt and weld combination connection, the deformation resistance of bolts and axial compression performance of specimens had been enhanced. However, the increase of bolt diameter from 12 to 18 mm resulted in a better strength degradation rate, but worse bearing capacity and deformation resistance. Finally, the predictions of the ultimate bearing capacity of PCSCFST columns under axial compression agree well with the test results, the average value of N-exp/N-pre and the variance are 0.998 and 0.00111.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Axial Compression Performance of Precast Circular Semi-Continuous Concrete-Filled Steel Tube Columns: Finite Element Analysis and Theoretical Modeling
    Cao, Bing
    Xie, Mingming
    Huang, Bo
    Hu, Gaoxing
    Wang, Jiawei
    BUILDINGS, 2023, 13 (02)
  • [2] Behavior of Concrete-Filled Steel Tube Columns Subjected to Axial Compression
    Li, Pengfei
    Zhang, Tao
    Wang, Chengzhi
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [3] Behavior of concrete-filled steel tube reinforced concrete columns subjected to axial compression
    Yao, Guohuang
    Li, Yongjin
    Liao, Feiyu
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (05): : 114 - 121
  • [4] Strength behavior of circular concrete-filled steel tube stub columns under axial compression: A review
    Wang, Xiuling
    Fan, Feifei
    Lai, Jinxing
    Construction and Building Materials, 2022, 322
  • [5] Strength behavior of circular concrete-filled steel tube stub columns under axial compression: A review
    Wang, Xiuling
    Fan, Feifei
    Lai, Jinxing
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 322
  • [6] Axial capacity of circular concrete-filled steel tube columns
    Mimoune, Mostefa
    Mimoune, Fatima Z.
    Youcef, Mourad Ait
    WORLD JOURNAL OF ENGINEERING, 2011, 8 (03) : 237 - 244
  • [7] Behavior of steel fiber reinforced concrete-filled steel tube columns under axial compression
    Lu, Yiyan
    Li, Na
    Li, Shan
    Liang, Hongjun
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 95 : 74 - 85
  • [8] Torsional Behavior of Concrete-Filled Circular Steel Tube Columns
    Lee, Eun-Taik
    Yun, B. H.
    Shim, H. J.
    Chang, K. H.
    Lee, George C.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2009, 135 (10): : 1250 - 1258
  • [9] Axial Compression Tests for Circular Concrete-Filled Steel Tube (CFST) Columns with Notch Imperfection
    Mustafa Mohammed
    Mustafa Fahmi Hasan
    Hasan Fahmi Hasan
    Alyaa Assad Mahdi
    Sarwar Hasan Mohmmad
    Mukhtar Hamid Abed
    KSCE Journal of Civil Engineering, 2024, 28 : 2304 - 2314
  • [10] Axial Compression Tests for Circular Concrete-Filled Steel Tube (CFST) Columns with Notch Imperfection
    Mohammed, Mustafa
    Hasan, Mustafa Fahmi
    Hasan, Hasan Fahmi
    Mahdi, Alyaa Assad
    Mohmmad, Sarwar Hasan
    Abed, Mukhtar Hamid
    KSCE JOURNAL OF CIVIL ENGINEERING, 2024, 28 (06) : 2304 - 2314