Defibrillation thresholds are increased by right-sided implantation of totally transvenous active can devices

被引:0
|
作者
Friedman, PA [1 ]
Trusty, JM [1 ]
Grice, SK [1 ]
Stanton, MS [1 ]
机构
[1] Mayo Clin, Rochester, MN USA
关键词
D O I
10.1016/S0735-1097(97)85170-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:334A / 334A
页数:1
相关论文
共 50 条
  • [1] Defibrillation thresholds are increased by right-sided implantation of totally transvenous implantable cardioverter defibrillators
    Friedman, PA
    Rasmussen, MJ
    Grice, S
    Trusty, J
    Glikson, M
    Stanton, MS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08): : 1186 - 1192
  • [2] Defibrillation thresholds are significantly increased by a right-sided approach to totally transvenous implantable defibrillator systems placement
    Friedman, PA
    Grice, S
    Espinosa, RE
    Stanton, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 68110 - 68110
  • [3] Increased defibrillation threshold with right-sided active pectoral can
    Roberts, PR
    Allen, S
    Betts, T
    Urban, JF
    Whitman, T
    Euler, DE
    Kallok, MJ
    Morgan, JM
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (01) : 245 - 249
  • [4] Increased defibrillation threshold with right-sided active pectoral can
    Roberts P.R.
    Allen S.
    Betts T.
    Urban J.F.
    Whitman T.
    Euler D.E.
    Kallok M.J.
    Morgan J.M.
    Journal of Interventional Cardiac Electrophysiology, 2000, 4 (1) : 245 - 249
  • [5] RIGHT-SIDED PECTORAL IMPLANTATION OF AN ACTIVE CAN TRANSVENOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR WITH SINGLE RIGHT-VENTRICULAR LEAD
    SCHOFIELD, IJ
    RANKIN, I
    BENNETT, DH
    BRITISH HEART JOURNAL, 1995, 74 (02): : 204 - 204
  • [6] Right sided transvenous implantation of active can cardioverter defibrillators: a save approach
    Fonteyne, W
    Rottiers, H
    Jordaens, L
    Tavernier, R
    EUROPEAN HEART JOURNAL, 2000, 21 : 198 - 198
  • [7] Optimization of transvenous coil position for active can defibrillation thresholds
    Gold, MR
    Olsovsky, MR
    Degroot, PJ
    Cuello, C
    Shorofsky, SR
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (01) : 25 - 29
  • [8] A prospective randomized comparison of transvenous and active Can atrial defibrillation thresholds
    Bouhouch, R
    Rashba, EJ
    Joy, RA
    Kirby, S
    Shorofsky, SR
    Osman, AF
    Gold, MR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 100A - 100A
  • [9] RANDOMIZED COMPARISON OF ASPIRIN AND PHENPROCOUMON FOR PREVENTION OF RIGHT-SIDED THROMBOEMBOLIC COMPLICATIONS ASSOCIATED WITH TRANSVENOUS DEFIBRILLATION LEADS
    JUNG, W
    FEHSKE, W
    MANZ, M
    HAGENDORFF, A
    OMRAN, H
    BIERSACK, HJ
    LUDERITZ, B
    EUROPEAN HEART JOURNAL, 1995, 16 (07) : 986 - 992
  • [10] Acute defibrillation threshold in 29 ICD transvenous implanted patients: Comparative analysis of the left and right-sided implants
    Melo, S. A.
    Oliveira, F. J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 : S92 - S92