Mapping 3D breast lesions from full-field digital mammograms using subject-specific finite element models

被引:1
|
作者
Garcia, E. [1 ]
Oliver, A. [1 ]
Diaz, O. [1 ]
Diez, Y. [2 ]
Gubern-Merida, A. [3 ]
Marti, R. [1 ]
Marti, J. [1 ]
机构
[1] Univ Girona, Inst Comp Vis & Robot, Girona, Spain
[2] Tohoku Univ, GSIS, Tokuyama Lab, Sendai, Miyagi, Japan
[3] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
关键词
Breast MRI; Full-Field digital Mammography; Multi-modal registration; Finite Element modelling;
D O I
10.1117/12.2255957
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Patient-specific finite element (FE) models of the breast have received increasing attention due to the potential capability of fusing images from different modalities. During the Magnetic Resonance Imaging (MRI) to X-ray mammography registration procedure, the FE model is compressed mimicking the mammographic acquisition. Subsequently, suspicious lesions in the MRI volume can be projected into the 2D mammographic space. However, most registration algorithms do not provide the reverse information, avoiding to obtain the 3D geometrical information from the lesions localized in the mammograms. In this work we introduce a fast method to localize the 3D position of the lesion within the MRI, using both cranio-caudal (CC) and medio-lateral oblique (MLO) mammographic projections, indexing the tetrahedral elements of the biomechanical model by means of an uniform grid. For each marked lesion in the Full-Field Digital Mammogram (FFDM), the X-ray path from source to the marker is calculated. Barycentric coordinates are computed in the tetrahedrons traversed by the ray. The list of elements and coordinates allows to localize two curves within the MRI and the closest point between both curves is taken as the 3D position of the lesion. The registration errors obtained in the mammographic space are 9.89 +/- 3.72 mm in CC- and 8.04 +/- 4.68 mm in MLO-projection and the error in the 3D MRI space is equal to 10.29 +/- 3.99 mm. Regarding the uniform grid, it is computed spending between 0.1 and 0.7 seconds. The average time spent to compute the 3D location of a lesion is about 8 ms.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [1] How accurately can subject-specific finite element models predict strains and strength of human femora? Investigation using full-field measurements
    Grassi, Lorenzo
    Vaananen, Sami P.
    Ristinmaa, Matti
    Jurvelin, Jukka S.
    Isaksson, Hanna
    JOURNAL OF BIOMECHANICS, 2016, 49 (05) : 802 - 806
  • [2] Volumetric breast density estimation from full-field digital mammograms
    van Engeland, S
    Snoeren, PR
    Huisman, H
    Boetes, C
    Karssemeijer, N
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (03) : 273 - 282
  • [3] Using Breast Tissue Information and Subject-Specific Finite-Element Models to Optimize Breast Compression Parameters for Digital Mammography
    Chang, Tien-Yu
    Wu, Jay
    Liu, Pei-Yuan
    Liu, Yan-Lin
    Luzhbin, Dmytro
    Lin, Hsien-Chou
    ELECTRONICS, 2022, 11 (11)
  • [4] Breast composition measurements from Full-Field Digital Mammograms using generative adversarial networks
    Garcia, E.
    Llado, X.
    Mann, R. M.
    Osuala, R.
    Marti, R.
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [5] Integrated full-field digital mammography and 3D breast ultrasound system
    Elbakri, I
    Entrekin, R
    Coad, C
    Danielson, T
    Janer, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1818 - 1818
  • [6] Volumetric Breast Density Estimation from Full-Field Digital Mammograms: A Validation Study
    Gubern-Merida, Albert
    Kallenberg, Michiel
    Platel, Bram
    Mann, Ritse M.
    Marti, Robert
    Karssemeijer, Nico
    PLOS ONE, 2014, 9 (01):
  • [7] How accurately can subject-specific finite element models predict strains and strength of human femora? Investigation using full-field measurements (vol 49, pg 802, 2016)
    Grassi, Lorenzo
    Vaananen, Sami P.
    Ristinmaa, Matti
    Jurvelin, Jukka S.
    Isaksson, Hanna
    JOURNAL OF BIOMECHANICS, 2019, 84 : 290 - 292
  • [8] Estimating breast density using a volumetric technique and full-field digital mammograms - Preliminary results
    Bloomquist, A
    Augustine, B
    Pawluczyk, O
    Mawdsley, GE
    Yaffe, MJ
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 705 - 712
  • [9] 3D Full-Field Deformation Measuring Technique Using Digital Image Correlation
    Nadarajah, Sujeeka
    Arulkumar, Vithushanthini
    Mallikarachchi, Chinthaka
    MERCON 2020: 6TH INTERNATIONAL MULTIDISCIPLINARY MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON), 2020, : 1 - 6
  • [10] Accurate 3D Reconstruction of Subject-Specific Knee Finite Element Model to Simulate the Articular Cartilage Defects
    董跃福
    胡广洪
    张罗莲
    胡杨
    董英海
    徐卿荣
    Journal of Shanghai Jiaotong University(Science), 2011, 16 (05) : 620 - 627